Edson Antonio Batista

Dr. Edson Antonio Batista

Federal University of Mato Grosso do Sul
+1

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 June 2022 in Electronics
Verified
Journal Article
Open access
PDF file
LPLuís Felipe da Silva Carlos Pereira
Luís Felipe da Silva Carlos Pereira
EBEdson Antonio Batista
Edson Antonio Batista
MBMoacyr Aureliano Gomes de Brito
Moacyr Aureliano Gomes de Brito
RGRuben Godoy
Ruben Godoy
In this paper, a new topology of a Fractional Order PID (FOPID) controller is proposed to control a boost DC-DC converter with minimum over/undershoot. The fractional controller parameters are tuned using a genetic algorithm (GA) with a combined cost function composed of the Integral of Time-Weighted Absolute Error (ITAE) and the Integral of Time-Weighted Square Error (ITSE). Despite adding moderate complexity to the control structure, the simulation results reveal that the GA-based FOPID controller tuning provided better performance for the setpoint tracking both under load variations and parameters deviation due to the prolonged use. The proposed FOPID shows a wide operational range concerning load disturbances, and capacitance/inductance deviations of ±30% and ±50% from nominal values, achieving functionality and voltage stability even with output power 50% higher than the converter power specification. The assessment was made considering operation in voltage mode and the performance was compared to conventional Proportional-Integral (PI), Type II and current mode controllers. Finally, a fuzzy fractional-order PID (FFOPID) was designed to outperform the FOPID during disturbances in the control variable.

26 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
MGMatheus Gomes
Matheus Gomes
JSJonathan De Andrade Silva
Jonathan De Andrade Silva
DGDiogo Gonçalves
Diogo Gonçalves
PZPedro Alberto Pereira Zamboni
Pedro Alberto Pereira Zamboni
JPJader Perez
Jader Perez
WGWesley Gonçalves
Wesley Gonçalves
Mapping utility poles using side-view images acquired with car-mounted cameras is a time-consuming task, mainly in larger areas due to the need for street-by-street surveying. Aerial images cover larger areas and can be feasible alternatives although the detection and mapping of the utility poles in urban environments using top-view images is challenging. Thus, we propose the use of Adaptive Training Sample Selection (ATSS) for detecting utility poles in urban areas since it is a novel method and has not yet investigated in remote sensing applications. Here, we compared ATSS with Faster Region-based Convolutional Neural Networks (Faster R-CNN) and Focal Loss for Dense Object Detection (RetinaNet ), currently used in remote sensing applications, to assess the performance of the proposed methodology. We used 99,473 patches of 256 × 256 pixels with ground sample distance (GSD) of 10 cm. The patches were divided into training, validation and test datasets in approximate proportions of 60%, 20% and 20%, respectively. As the utility pole labels are point coordinates and the object detection methods require a bounding box, we assessed the influence of the bounding box size on the ATSS method by varying the dimensions from 30×30 to 70×70 pixels. For the proposal task, our findings show that ATSS is, on average, 5% more accurate than Faster R-CNN and RetinaNet. For a bounding box size of 40×40, we achieved Average Precision with intersection over union of 50% (AP50) of 0.913 for ATSS, 0.875 for Faster R-CNN and 0.874 for RetinaNet. Regarding the influence of the bounding box size on ATSS, our results indicate that the AP50 is about 6.5% higher for 60×60 compared to 30×30. For AP75, this margin reaches 23.1% in favor of the 60×60 bounding box size. In terms of computational costs, all the methods tested remain at the same level, with an average processing time around of 0.048 s per patch. Our findings show that ATSS outperforms other methodologies and is suitable for developing operation tools that can automatically detect and map utility poles.

24 August 2020 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
RCRaymundo Cordero
Raymundo Cordero
Thyago Vasconcelos EstrabisThyago Vasconcelos Estrabis
Thyago Vasconcelos Estrabis
EBEdson Antonio Batista
Edson Antonio Batista
CACristiano Quevedo Andrea
Cristiano Quevedo Andrea
GGGabriel Gentil
Gabriel Gentil
This brief proposes an adaptation of the Generalized Predictive Control (GPC) for ramp-reference tracking. The second-order difference operation and the plant model are used to get an augmented model with two embedded integrators and whose output is the tracking error. Differently from other GPC-based tracking algorithms, the proposed approach does not require information about the reference parameters, and the GPC prediction horizon is composed of the predicted errors instead of the expected plant outputs. Thus, the optimization function and the receding horizon strategy used in conventional GPC can be applied to get the control law. Simulation and experimental results prove that the proposed approach can successfully track constant and ramp references. The proposed method is applicable for single-input single-outputs plants. However, the mathematical background presented in this brief can be used in the development of new GPC strategies.

10 February 2021 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
RCRaymundo Cordero
Raymundo Cordero
Thyago Vasconcelos EstrabisThyago Vasconcelos Estrabis
Thyago Vasconcelos Estrabis
GGGabriel Gentil
Gabriel Gentil
EBEdson Antonio Batista
Edson Antonio Batista
CACristiano Quevedo Andrea
Cristiano Quevedo Andrea
Some important applications require control systems capable of tracking high-degree polynomial references. However, polynomial reference tracking is difficult because the controller must have a fast response to track variable references. Generalized Predictive Control (GPC), used in industrial applications, has a fast response. However, up to now, GPC approaches in the literature are not designed for high-degree polynomial reference tracking. For that reason, this brief proposes a GPC system for the tracking of polynomial references of any degree. The high-order backward difference operator was used to develop an augmented prediction model designed to have an arbitrary number of embedded integrators. Thus, according to the internal model principle, the proposed predictive controller can track polynomial references of any degree. An optimization technique is used to define future control actions, while the control law is defined through the receding horizon principle. Simulation and experimental results prove that the proposed controller performs better than other approaches described in the literature.

9 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MBMoacyr Aureliano Gomes de Brito
Moacyr Aureliano Gomes de Brito
Guilherme Mendonça MartinesGuilherme Mendonça Martines
Guilherme Mendonça Martines
AVAnderson S. Volpato
Anderson S. Volpato
RGRuben Godoy
Ruben Godoy
EBEdson Antonio Batista
Edson Antonio Batista
This paper presents novel current sensorless maximum-power point-tracking (MPPT) algorithms based on compensators/controllers and a single-input voltage sensor. The proposed MPPTs eliminate the expensive and noisy current sensor, which can significantly reduce the system cost and retain the advantages of the widely used MPPT algorithms, such as Incremental Conductance (IC) and Perturb and Observe (P&O) algorithms. Additionally, it is verified that the proposed algorithms, especially the proposed Current Sensorless V based on PI, can reach outstanding tracking factors (TFs) such as the IC and P&O based on PI algorithms. In this sense, the insertion of controllers inside the MPPT gives them adaptive characteristics, and the experimental TFs are in the remarkable range of more than 99%, with an average yield of 99.51% and a peak of 99.80%.

22 March 2023 in IEEE Access
Verified
Journal Article
Open access
LPLuís Felipe da Silva Carlos Pereira
Luís Felipe da Silva Carlos Pereira
EBEdson Antonio Batista
Edson Antonio Batista
JPJoāo Onofre Pereira Pinto
Joāo Onofre Pereira Pinto
BUBelle R. Upadhyaya
Belle R. Upadhyaya
JHJ. Wesley Hines
J. Wesley Hines
This paper proposes a generalized predictive control (GPC) with constraints and orthonormal Laguerre functions using the simplified model of the primary system (reactor core and intermediate heat exchanger (IHX)) of a prototypical sodium fast reactor (SFR). This paper develops a multiple-input multiple-output (MIMO) GPC with input constraints able to track polynomial references of any degree applied in coolant temperature difference across the core and fractional power. The manipulated variables of the GPC-SFR are the reactivity and the sodium flow rate of the primary and secondary pipes. Moreover, orthonormal Laguerre functions and step down condition number techniques were also applied to avoid the numerical ill-conditioning issue in quadratic programming of large systems. Thus, a GPC type-2 was designed to control fractional power, coolant temperature difference across the core and sodium tank temperature of the SFR primary system when temperature references change according to a linear ramp after reaching their steady-state operation, sustaining 100% power operation on the reactor. In order to analyze the load tracking capability of the GPC-SFR type-2, the load following from 100% fractional power (FP) to 60% FP at 0.8% FP/min rate is simulated. Constraints on the rate of coolant temperature difference across the core and reactivity were applied for the design safety. For comparison criteria, this paper compares the GPC-SFR type-2 with the GPC-SFR type-1, i.e, standard model predictive control (MPC), to verify the viability and superior performance of the proposal regarding: (a) ramp-tracking capability of temperature and load; (b) the rejections of a reactivity disturbance of -1 cent and a secondary sodium inlet temperature disturbance of +10°F; and (c) a simulation with uncertainty in reactor design. The simulations show that the GPC-SFR type-2 overcome the GPC-SFR type-1 robustness and performance.