The present study reports the development of a deep learning artificial intelligence (AI) model for predicting the thermal performance of evaporative cooling systems, which are widely used for thermal comfort in different applications. The existing, conventional methods for the analysis of evaporation-assisted cooling systems rely on experimental, mathematical, and empirical approaches in order to determine their thermal performance, which limits their applications in diverse and ambient spatiotemporal conditions. The objective of this research was to predict the thermal performance of three evaporation-assisted air-conditioning systems—direct, indirect, and Maisotsenko evaporative cooling systems—by using an AI approach. For this purpose, a deep learning algorithm was developed and lumped hyperparameters were initially chosen. A correlation analysis was performed prior to the development of the AI model in order to identify the input features that could be the most influential for the prediction efficiency. The deep learning algorithm was then optimized to increase the learning rate and predictive accuracy with respect to experimental data by tuning the hyperparameters, such as by manipulating the activation functions, the number of hidden layers, and the neurons in each layer by incorporating optimizers, including Adam and RMsprop. The results confirmed the applicability of the method with an overall value of R2 = 0.987 between the input data and ground-truth data, showing that the most competent model could predict the designated output features (, , and ). The suggested method is straightforward and was found to be practical in the evaluation of the thermal performance of deployed air conditioning systems under different conditions. The results supported the hypothesis that the proposed deep learning AI algorithm has the potential to explore the feasibility of the three evaporative cooling systems in dynamic ambient conditions for various agricultural and livestock applications.
In Pakistan, groundwater resources are depleting at an alarming rate due to intensive pumping, shifting of cropping patterns, and climate change vulnerability. The present study is aimed at investigating groundwater stress in the command area of Lower Chenab Canal (LCC) and associated branch canals. Groundwater stress is determined by considering the cropping patterns, surface water availability, groundwater levels, climatic variation, and crop water requirement (CWR) in the LCC command area. The climatic data is obtained from the Pakistan Meteorological Department (PMD) from 1990 to 2020. The records of temporal variation in cropping patterns are obtained from the Crop Reporting Service (CRS), Directorate of Agriculture, Lahore for the 1995–2020 period and classified according to Rabi season (November to April) and Kharif season (May to October). The LCC surface water flows data and groundwater levels are collected from the Punjab Irrigation Department (PID) Lahore from 2003 to 2018 and from 1995 to 2016, respectively. The CWR is estimated using the Cropwat 8.0 model and groundwater levels are estimated using the Inverse Distance Weighted (IDW) tool of ArcGIS software. It has been determined that Faisalabad, Sheikhupura, and Toba Tek Singh are highly groundwater stress cities having an average drawdown rate of 0.58 m/year. The surface water availability is also decreased from 7.75 to 4.81 billion cubic meters (Bm3) for the Kharif season whilst 4.17 to 2.63 Bm3 for the Rabi season. This study concluded that due to severe conditions in highly stressed areas, policy planners, decision-makers, and stakeholders should sincerely take some steps for maintaining groundwater levels either by capacity building workshops for the farmers or limiting the number of tubewells.
In Pakistan, many subsurface (SS) drainage projects were launched by the Salinity Control and Reclamation Project (SCARP) to deal with twin problems (waterlogging and salinity). In some cases, sump pumps were installed for the disposal of SS effluent into surface drainage channels. Presently, sump pumps have become dysfunctional due to social and financial constraints. This study evaluates the alternate design of the Paharang drainage system that could permit the discharge of the SS drainage system in the response of gravity. The proposed design was completed after many successive trials in terms of lowering the bed level and decreasing the channel bed slope. Interconnected MS-Excel worksheets were developed to design the L-section and X-section. Design continuity of the drainage system was achieved by ensuring the bed and water levels of the receiving drain were lower than the outfalling drain. The drain cross-section was set within the present row with a few changes on the service roadside. The channel side slope was taken as 1:1.5 and the spoil bank inner and outer slopes were kept as 1:2 for the entire design. The earthwork was calculated in terms of excavation for lowering the bed level and increasing the drain section to place the excavated materials in a specific manner. The study showed that modification in the design of the Paharang drainage system is technically admissible and allows for the continuous discharge of SS drainage effluent from the area.
The present study aims to evaluate the performance of evaporation-assisted humidification–dehumidification (E-HDH) desalination, specifically direct evaporative (DE-HDH), indirect evaporative (IE-HDH), and Maisotsenko evaporative (ME-HDH) systems. To achieve this, a thermodynamic modeling approach is utilized, which incorporates the wet bulb effectiveness method, psychrometric relationships of humid air, and equations that govern heat and mass balance. The key performance indicators of the studied E-HDH desalination systems are estimated concerning operating parameters. The results show that the ME-HDH system is capable of producing a comparatively higher water production rate (WPR) ranging between 0.01 and 7.92 g/s as compared to the DE-HDH and IE-HDH systems. The sensible cooling flux was observed to be high at a dry-bulb temperature (Tdb) of 50 °C and relative humidity (RH) < 0.2, having a value of 5.26 kW for the DE-HDH system, followed by the ME-HDH system (3.23 kW) and the IE-HDH system (3.11 kW) due to relatively high mass flow rates. The latent heat flux was observed to be relatively high in the case of the ME-HDH system. Minimum specific energy consumption was observed from the ME-HDH system, and consequently, a maximum gain output ratio (3.32) was realized. In addition, the study realized that an increment in air velocity and wet bulb effectiveness significantly improves the WPR. In accordance with the climatic conditions of the studied Saudi Arabia cities, it has been realized that Al-Hofuf and Riyadh produce relatively high WPRs with minimum energy consumption. In the case of Al-Hofuf, the average WPR was recorded as 185.51 kg/day, followed by Riyadh (180.33 kg/day). The energy required was estimated to be 0.042 kWh/kg and 0.034 kWh/kg for both cities, accordingly.
Globally, warmer lakes disrupt thermal balance, causing hypoxia, salinization, biodiversity loss, and increased evaporation. Conventional floating covers used to reduce evaporation absorb sunlight and warm the underlying water, limiting suppression efficiency to less than the coverage ratio (η eff /Φ ≤ 1). Here, we break this limit by developing Superhydrophobic Radiative Cooling Covers (SRCC) via multi‐level structural design. SRCC actively cools the water surface by combining high solar reflectance, strong mid‐infrared emission, and superhydrophobicity. Experiments show SRCC lowers water temperature by 2.2°C versus uncovered water, achieving 93.1± 0.1% evaporation suppression at 91% coverage, yielding η eff /Φ > 1.0 for the first time. Large‑scale simulations for nine Chinese lakes indicate that SRCC reduces water temperature by 4.87°C (vs. no cover) and by 12.44 °C (vs. black covers). This cooling could increase annual freshwater reserves by 10.78 km 3 across China under full deployment, equivalent to 20.9 L per person per day. Unattainable with conventional covers, SRCC uniquely mitigates thermal accumulation while enhancing freshwater storage, providing a quantifiable engineering solution to climate‑driven water stress and enabling adaptive lake ecosystem management across regional and global scales.
Phenol resins (PRs) are considered as relatively inexpensive adsorbents synthesized from agricultural biomass via employing a variety of synthesized procedures. The performance of PR for heat transformation application is not widely investigated. In this regard, the present study aims to evaluate the four PR derivative/refrigerant pairs, namely (i) KOH6-PR/CO2, (ii) SAC-2/HFC, (iii) KOH4-PR/ethanol, and (iv) KOH6-PR/ethanol, for adsorption cooling and adsorption heating applications. Ideal cycle analyses and/or thermodynamic modelling approaches were utilized comprising governing heat and mass balance equations and adsorption equilibrium models. The performance of the AHP system is explored by means of specific cooling energy (SCE), specific heating energy (SHE), and coefficient of performance (COP), both for cooling and heating applications, respectively. It has been realized that KOH6-PR/ethanol could produce a maximum SCE of 1080 kJ/kg/cycle and SHE of 2141 kJ/kg/cycle at a regeneration temperature (Treg) and condenser temperature (Tcond) of 80 °C, and 10 °C, respectively, followed by KOH4-PR/ethanol, SAC-2/HFC-32, and KOH6-PR/CO2. The maximum COP values were estimated to be 1.78 for heating and 0.80 for cooling applications, respectively, at Treg = 80 °C and Tcond = 10 °C. In addition, the study reveals that, corresponding to increase/decrease in condenser/evaporator pressure, both SCE and SHE decrease/increase, respectively; however, this varies in magnitude due to adsorption equilibrium of the studied PR derivative/refrigerant pairs.