HEMAKESAVULU ORUGANTI

Mr. HEMAKESAVULU ORUGANTI

SRM Institute of Science and Technology
+1
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2018 in Energies
Verified
Journal Article
Open access
PDF file
HEMAKESAVULU ORUGANTIHEMAKESAVULU ORUGANTI
HEMAKESAVULU ORUGANTI
SDSubranshu Sekhar Dash
Subranshu Sekhar Dash
CNChellammal Nallaperumal
Chellammal Nallaperumal
SRSridhar Ramasamy
Sridhar Ramasamy
Photovoltaic (PV) resources are connected to power grid through voltage source inverters. The quality of power output from PV inverter should be in grid compliance of IEEE standard. In this regard, the deployment of appropriate low pass filters such as inductor (L), capacitor (C) or inductor capacitor inductor (LCL) is critical as they aid in minimizing the harmonics being injected into the grid. LCL filters are well entrenched but they bring in stability issue due to resonance and therefore a damping controller with suitable control logic is needed. In this work, to suppress resonance, a Proportional Resonant-Derivative (PR-D) controller has been designed, proposed, and compared with existing counterparts, i.e., two-degree of freedom controller (2DOF) and feedback current controller. The results exhibits that PR-D controller admits meliorate resonance damping and constancy when compared with the two other schemes. The whole system has been simulated in MATLAB/Simulink environment and a prototype has also been made to ensure the performance.

1 January 2021 in Advances in Materials Science and Engineering
Verified
Journal Article
Open access
PDF file
MMMadhan Mohankumar
Madhan Mohankumar
ASA. N. Shankar
A. N. Shankar
TKT. S. Karthik
T. S. Karthik
RSRengaraj Saravanakumar
Rengaraj Saravanakumar
HEMAKESAVULU ORUGANTIHEMAKESAVULU ORUGANTI
HEMAKESAVULU ORUGANTI
NRN. Rakesh
N. Rakesh
This study was conducted to assess and compare the crack‐healing ability of conventional electrical sintered and microwave sintered Al2O3/x wt. % SiC (x = 5, 10, 15, and 20) structural ceramic composites. The crack‐healing ability of both conventional electrical sintered and microwave sintered specimens was studied by introducing a crack of ∼100 µm length by Vickers’s indentation and conducting a heat treatment at 1200°C for dwell time of 1 h in air. The flexural or bending strength of sintered, cracked, and crack‐healed specimens was determined by three‐point bending test, and the phase variations by X‐ray diffraction and SEM micrographs before and after crack‐healing of both the sintering methods were studied and compared. The results show that almost all the specimens recovered their strength after crack‐healing, but the strength of microwave sintered Al2O3/SiC structural ceramic composites has been shown to be better than that of conventional electrical sintered Al2O3/SiC structural ceramic composites. The microwave sintered crack‐healed Al2O3/10 wt. % SiC specimen shows higher flexural strength of 794 MPa, which was 105% when compared with conventional electrical sintered Al2O3/10 wt. % SiC and crack‐healed Al2O3/10 wt. % SiC specimen. It was found by X‐ray diffractogram that before crack‐healing, all the conventional electrical sintered samples have SiO2 phase which reduce the crack‐healing ability and microwave sintered samples with 15 and 20 wt. % SiC show lesser SiO2 phase and 5 and 10 wt. % SiC samples have no SiO2 phase before crack‐healing. However, after crack‐healing treatment, all the samples have distinct SiO2 phase along with Al2O3 and SiC phases. Microwave sintered Al2O3/10 wt. % SiC specimen cracks were fully healed which was evident in SEM micrographs.

14 May 2019 in International Journal of Electrical Engineering & Education
Verified
Journal Article
Closed access
PDF file
HEMAKESAVULU ORUGANTIHEMAKESAVULU ORUGANTI
HEMAKESAVULU ORUGANTI
SDSubranhsu Sekhar Dash
Subranhsu Sekhar Dash
CNChellammal Nallaperumal
Chellammal Nallaperumal
Photovoltaic power generation has transformed into the most reassuring strategy for power generation among the renewable sources in view of its intrinsic favorable circumstances. The significant snag that photovoltaic system poses like other inexhaustible sources is the power intermittency in regard to atmospheric conditions like irradiation and temperature. These photovoltaic systems are interfaced to the grid through filters via inverters to prevent harmonics getting in to the grid. Generally, inductor–capacitor–inductor filters are employed in grid-connected system, as they provide better harmonic attenuation than inductor and inductor-capacitor filters. However, they bring resonance as well as oscillations into the grid-connected system. So, in order to suppress the resonance that brings instability problems in the system, active damping control strategies are adopted. But these conventional active damping methods increase the complexity of the system as they need extra sensors. This article proposes a fuzzy logic control-based active damping method to ease the control activity. The proposed controller is contrasted with the injected grid current feedback controller to investigate the resonance damping and the stability of grid interfaced multilevel inverter with inductor–capacitor–inductor filter. When compared with the injected grid current feedback controller, the fuzzy logic control approach promises satisfactory performance based on harmonic content, resonance peak, and stability analysis. The compliance according to the industrial standard in terms of harmonics is met in this article and is duly documented within the manuscript. Simulation results verify the design strategies and the effectiveness of the proposed fuzzy logic control strategy.

28 May 2019 in International Journal of Ambient Energy
Verified
Journal Article
Closed access
HEMAKESAVULU ORUGANTIHEMAKESAVULU ORUGANTI
HEMAKESAVULU ORUGANTI
SDSubhransu Sekhar Dash
Subhransu Sekhar Dash
NCN. Chellammal
N. Chellammal
MLM. Padma Lalitha
M. Padma Lalitha
LCL(Inductor,Capacitor & Inductor) filters are commonly employed in grid allied system, provide better harmonic attenuation than L(Inductor) and LC(Inductor & Capacitor) filters. They bring resonance in addition to oscillations into grid coupled system. With the intention to mitigate the resonance that brings instability problems in the system, active damping control strategies are adopted. Active damping method based fuzzy logic control to ease control action on considered scheme is focused in this atricle. The projected controller is compared with the existing injected grid current feedback controller to investigate the resonance damping and stability of grid interfaced LCL filter by multilevel inverter. When compared with injected grid current feedback controller, satisfactory performance based on harmonic content, resonance peak and stability is met by the fuzzy logic control approach. Simulation analyses justify the design strategies and the efficacy of fuzzy logic control.

5 January 2025 in Micromachines
Verified
Journal Article
Open access
PDF file
CCChandra College of Engineering sekhar C
Chandra College of Engineering sekhar C
Mohammed Mahaboob BashaMohammed Mahaboob Basha
Mohammed Mahaboob Basha
SDS MOHAN DAS
S MOHAN DAS
HEMAKESAVULU ORUGANTIHEMAKESAVULU ORUGANTI
HEMAKESAVULU ORUGANTI
MDMohan Dholvan
Mohan Dholvan
JSJaved Syed
Javed Syed
In modern ICs, sub-threshold voltage management plays a significant role due to its perspective on energy efficiency and speed performance. Level shifters (LSs) play a critical role in signal exchange among multiple voltage domains by ensuring signal integrity and the reliable operation of ICs. In this article, a Pass-Transistor-Enabled Split Input Voltage Level Shifter (PVLS) is designed for area, delay, and power-efficient applications with a wide voltage conversion range. The represented low-power LS structure is a general blend of both pull-up and pull-down networks that perform level-up or level-down shifts. The proposed PVLS is incorporated with the multi-threshold CMOS technique and a load-balancing driving split inverter to limit high static current, leakage power, and performance degradation. The schematic structure could be able to convert voltages from low to high as well as high to low. The architecture design has the lowest silicon area. The implementation of the proposed design was taken under 55 nm CMOS technology. The represented LS could be able to convert voltage ranges between 0.3 V and 1.3 V, which has a dynamic power of 2.00 nW. The overall propagation delay of the LS is 90 ps and an area of 7.66 µm2 for an input frequency of 1 MHz.

25 September 2019 in Lecture Notes in Electrical Engineering
Verified
Book Chapter
Closed access
PDF file
MLMareddy Padma Lalitha
Mareddy Padma Lalitha
HEMAKESAVULU ORUGANTIHEMAKESAVULU ORUGANTI
HEMAKESAVULU ORUGANTI