Iratxe Agustin

Prof. Iratxe Agustin

Zaragoza University
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Journal of Clinical and Experimental Dentistry
Verified
Journal Article
Closed access
DCD. Chávarri-Prado
D. Chávarri-Prado
Aritza Brizuela-VelascoAritza Brizuela-Velasco
Aritza Brizuela-Velasco
MDM. Diéguez-Pereira
M. Diéguez-Pereira
EPEsteban Pérez-Pevida
Esteban Pérez-Pevida
AJA. Jiménez-Garrudo
A. Jiménez-Garrudo
OMO. Montalbán-Vadillo
O. Montalbán-Vadillo
This study aimed to evaluate the effect of the implant design and the presence of cortical bone in the primary stability, as well as analyze the differences between the stability measurements obtained by two different resonance frequency analysis (RFA) devices. A total of 80 Klockner implants of two different models [40 Essential Cone implants (group A) and 40 Vega implants (group B)] were used. The implants were placed in two polyurethane blocks that simulated the mechanical properties of the maxillary bone. One block featured a layer of cortical bone that was absent from the other block. The primary stability of all implants was measured by insertion torque and RFA using two different devices: Penguin RFA and Osstell IDX. Primary stability was superior in the cortical bone in both torque and RFA. In the block containing cortical bone, group A implants obtained a greater insertion torque than did group B. The insertion torque was lesser in the bone lacking cortex. Regarding the ISQ of the implants, group A presented higher values in the block with cortical bone, but the values were lower in the block without cortical bone. There were no significant differences between the values obtained from the Osstell IDX and Penguin RFA. The presence of cortical bone positively influences the primary stability of dental implants. The design of the implant also has a statistically significant influence on implant primary stability, although the impact depends on whether there is coronal cerclage or not. There were no statistically significant differences in the implant stability measurements obtained by two different devices. Key words:Implant stability, resonance frequency analysis, torque, osstell, penguin, cortical.

28 December 2020 in Biology
Verified
Journal Article
Open access
PDF file
DCDavid Chavarri-Prado
David Chavarri-Prado
Aritza Brizuela-VelascoAritza Brizuela-Velasco
Aritza Brizuela-Velasco
ÁÁÁngel Álvarez-Arenal
Ángel Álvarez-Arenal
MDMarkel Dieguez-Pereira
Markel Dieguez-Pereira
EPEsteban Pérez-Pevida
Esteban Pérez-Pevida
AMAlejandro Estrada Martínez
Alejandro Estrada Martínez
Objectives: To determine the effect of mechanical loading of bone on the stability and histomorphometric variables of the osseointegration of dental implants using an experimental test in an animal model. Materials and Methods: A total of 4 human implants were placed in both tibiae of 10 New Zealand rabbits (n = 40). A 6-week osseointegration was considered, and the rabbits were randomly assigned to two groups: Group A (Test group) included 5 rabbits that ran on a treadmill for 20 min daily during the osseointegration period; Group B (Controls) included the other 5 that were housed conventionally. The monitored variables were related to the primary and secondary stability of the dental implants (implant stability quotient—ISQ), vertical bone growth, bone to implant contact (BIC), area of regenerated bone and the percentage of immature matrix. Results: The results of the study show a greater vertical bone growth (Group A 1.26 ± 0.48 mm, Group B 0.32 ± 0.47 mm, p < 0.001), higher ISQ values (Group A 11.25 ± 6.10 ISQ, 15.73%; Group B 5.80 ± 5.97 ISQ, 7.99%, p = 0.006) and a higher BIC (Group A 19.37%, Group B 23.60%, p = 0.0058) for implants in the test group, with statistically significant differences. A higher percentage of immature bone matrix was observed for implants in the control group (20.68 ± 9.53) than those in the test group (15.38 ± 8.84) (p = 0.108). A larger area of regenerated bone was also observed for the test implants (Group A 280.50 ± 125.40 mm2, Group B 228.00 ± 141.40 mm2), but it was not statistically significant (p = 0.121). Conclusions: The mechanical loading of bone improves the stability and the histomorphometric variables of the osseointegration of dental implants.

1 December 2019 in Journal of Dental Sciences
Verified
Journal Article
Open access
EPEsteban Pérez-Pevida
Esteban Pérez-Pevida
Aritza Brizuela-VelascoAritza Brizuela-Velasco
Aritza Brizuela-Velasco
DCDavid Chávarri-Prado
David Chávarri-Prado
MDMarkel Diéguez-Pereira
Markel Diéguez-Pereira
AJAntonio Jiménez-Garrudo
Antonio Jiménez-Garrudo
GSGorka Santamaría-Arrieta
Gorka Santamaría-Arrieta

Verified
Journal Article
Open access
PDF file
OMOier Montalbán-Vadillo
Oier Montalbán-Vadillo
EPEsteban Pérez-Pevida
Esteban Pérez-Pevida
IAIratxe Agustin
Iratxe Agustin
DCDavid Chavarri-Prado
David Chavarri-Prado
AMAlejandro Estrada Martínez
Alejandro Estrada Martínez
Aritza Brizuela-VelascoAritza Brizuela-Velasco
Aritza Brizuela-Velasco
Background: Although xenografts have shown successful results in GBR procedures due to their osteoconductive properties, many authors have opted to add co-adjuvant drugs to favor osteogenesis and differentiate cells into an osteoblastic lineage. Metformin has been shown to have bone-protective properties, regulating osteoclast differentiation, as well as the ability to promote osteoblast mineralization and differentiation. The present study aimed to evaluate the effect of the local application of a 1% metformin solution on bone neoformation in the treatment of an experimental bone defect in a guided bone regeneration animal model with a particulated bovine hydroxyapatite xenograft with hyaluronate. Methods: With this purpose in mind, two critical defects with 8 mm diameter and 0.5 mm depth were created in eight male New Zealand rabbit calvarias. Titanium cylinders were fixed in each defect and filled with particulate hydroxyapatite of bovine origin and sodium hyaluronate, with sterile injectable saline added to the control group and sterile 1% metformin solution added to the test group. At 6 weeks, the animals were euthanized, and samples were obtained and prepared for histomorphometric analysis. Results: A higher percentage of new bone formation was observed in the metformin samples than in the control samples, both in the region closest to the animal’s calvaria and in the most distal region analyzed. A higher average bone–biomaterial contact percentage was observed in the samples, with metformin in both the proximal and distal regions. There was no statistically significant difference in the mean value in either region in both parameters. Conclusion: The local application of a 1% metformin solution in an animal model of guided bone regeneration with particulate bovine hydroxyapatite and hyaluronate resulted in greater bone neoformation and xenograft osseointegration than in the control group.

1 January 2019 in DYNA Ingenieria e Industria
Verified
Journal Article
Closed access
Aritza Brizuela-VelascoAritza Brizuela-Velasco
Aritza Brizuela-Velasco
AGAntonio Jimenez Garrudo
Antonio Jimenez Garrudo
IAIratxe Agustin
Iratxe Agustin
DPDavid Chavarri Prado
David Chavarri Prado
EPEsteban Perez Pevida
Esteban Perez Pevida
JBJose Manuel Lou Bonafonte
Jose Manuel Lou Bonafonte

1 September 2020 in The International Journal of Oral and Maxillofacial Implants
Verified
Journal Article
Closed access
IAIratxe Agustin
Iratxe Agustin
Aritza Brizuela-VelascoAritza Brizuela-Velasco
Aritza Brizuela-Velasco
JLJose Lou-Bonafonte
Jose Lou-Bonafonte
AJAntonio Jiménez-Garrudo
Antonio Jiménez-Garrudo
DCDavid Chávarri-Prado
David Chávarri-Prado
RGReinhard Gruber
Reinhard Gruber
Iratxe Viteri-Agust?n, DDS/Aritza Brizuela-Velasco, PhD/Jose Manuel Lou-Bonafonte, PhD/Antonio Jim?nez-Garrudo, DDS/David Ch?varri-Prado, DDS/Esteban P?rez-Pevida, PhD/Lorena Benito-Garz?n, PhD/Reinhard Gruber, PhD: Purpose: Compaction of particulated grafts is done manually; thus, the effect of compression force on bone regeneration remains unclear. The aim of this study was to evaluate the impact of two different compression forces on the consolidation of particulated bovine hydroxyapatite. Materials and Methods: Two titanium cylinders were fixed on the calvarium of eight New Zealand rabbits. Both defects were filled with particulated bovine hydroxyapatite subjected to a compression force of 0.7 kg/cm2 or 1.6 kg/cm2 before being covered with a resorbable collagen membrane. A handheld device that uses a spring to control the compression force applied by the plugger was used. At 6 weeks, histomorphometry of the area immediately adjacent to the calvaria bone and to the collagen membrane was performed. Results: It was shown that next to the calvaria, the bone volume per tissue volume (BV/TV) was 29.0% ± 8.8% and 27.6% ± 8.2% at low and high compression force, respectively; the bone-to-biomaterial contact (BBC) was 58.2% ± 25.0% and 69.3% ± 22.9%, respectively (P > .05). In the corresponding area next to the collagen membrane, BV/TV was 4.9% ± 5.1% and 5.7% ± 4.7%, and the BBC was 18.3% ± 20.8% and 20.1% ± 15.9%, respectively (P > .05). In addition, the number and area of blood vessels were not significantly affected by compression force. Conclusion: Both compression forces applied resulted in similar consolidation of bovine hydroxyapatite expressed by new bone formation and vascularization based on a rabbit calvaria augmentation model.