Luca Massari

Luca Massari

Auto-generated profile, based on publicly available information

Luca Massari

The BioRobotics Institute, Scuola Superiore Sant’Anna, Pisa, Italy

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2020 in IEEE Access
Verified
Journal Article
Open access
Daniela Lo PrestiDaniela Lo Presti
Daniela Lo Presti
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Catia LeitaoCatia Leitao
Catia Leitao
Maria de Fátima DominguesMaria de Fátima Domingues
Maria de Fátima Domingues
MSMarzhan Sypabekova
Marzhan Sypabekova
Emiliano SchenaEmiliano Schena
Emiliano Schena
In the last decades, fiber Bragg gratings (FBGs) have become increasingly attractive to medical applications due to their unique properties such as small size, biocompatibility, immunity to electromagnetic interferences, high sensitivity and multiplexing capability. FBGs have been employed in the development of surgical tools, assistive devices, wearables, and biosensors, showing great potentialities for medical uses. This paper reviews the FBG-based measuring systems, their principle of work, and their applications in medicine and healthcare. Particular attention is given to sensing solutions for biomechanics, minimally invasive surgery, physiological monitoring, and medical biosensing. Strengths, weaknesses, open challenges, and future trends are also discussed to highlight how FBGs can meet the demands of nextgeneration medical devices and healthcare system.

6 November 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JTJoshua Di Tocco
Joshua Di Tocco
Daniela Lo PrestiDaniela Lo Presti
Daniela Lo Presti
Martina ZaltieriMartina Zaltieri
Martina Zaltieri
GDGiacomo D'Alesio
Giacomo D'Alesio
MFMariangela Filosa
Mariangela Filosa
Emiliano SchenaEmiliano Schena
Emiliano Schena
Workers experiencing high levels of stress may suffer from poor motivation, low level of attention, and physical disorders which, in turn, may lead to work injuries. Respiratory frequency (f R ) is considered one of the most reliable indicators of the mental load and fatigue state of workers. Monitoring this parameter through wearable devices represents an efficient solution for the maintenance of Occupational Health and Safety. We developed an innovative wearable system equipped with flexible sensors based on fiber Bragg gratings (FBGs) to monitor f R in static and dynamic conditions characterizing occupational settings. This article provides a description of the system and of the metrological characteristics of the flexible sensors in terms of response to strain and temperature changes, and hysteresis error. The performances of the device, evaluated in a laboratory during the execution of tasks mimicking real work activity, are also reported. The obtained promising results encourage the engineering of the system for use in real workplaces to collect quantitative information on the psychophysical state of workers and its relation to stress level.

2 February 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
DFDavide Ferraro
Davide Ferraro
GDGiacomo D'ALesio
Giacomo D'ALesio
DCDomenico Camboni
Domenico Camboni
CZCiro Zinno
Ciro Zinno
LCLeone Costi
Leone Costi
Calogero Maria OddoCalogero Maria Oddo
Calogero Maria Oddo
Continuous and reliable cardiac function monitoring could improve medication adherence in patients at risk of heart failure. This work presents an innovative implantable Fiber Bragg Grating-based soft sensor designed to sense mechanical cardiac activity. The sensor was tested in an isolated beating ovine heart platform, with 3 different hearts operated in wide-ranging conditions. In order to investigate the sensor capability to track the ventricular beats in real-time, two causal algorithms were proposed for detecting the beats from sensor data and to discriminate artifacts. The first based on dynamic thresholds while the second is a hybrid convolutional and recurrent Neural Network. An error of 2.7 ± 0.7 beats per minute was achieved in tracking the heart rate. Finally, we have confirmed the sensor reliability in monitoring the heart activity of healthy adult minipig with an error systematically lower than 1 Bpm.

10 November 2020 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
DCDomenico Camboni
Domenico Camboni
LMLuca Massari
Luca Massari
Marcello ChiurazziMarcello Chiurazzi
Marcello Chiurazzi
RCRenato Caliò
Renato Caliò
JAJoan Ortega Alcaide
Joan Ortega Alcaide
GCGastone Ciuti
Gastone Ciuti
An endoscopic tactile robotic capsule, embedding miniaturized MEMS force sensors, is presented. The capsule is conceived to provide automatic palpation of non-polypoid colorectal tumours during colonoscopy, since it is characterized by high degree of dysplasia, higher invasiveness and lower detection rates with respect to polyps. A first test was performed employing a silicone phantom that embedded inclusions with variable hardness and curvature. A hardness-based classification was implemented, demonstrating detection robustness to curvature variation. By comparing a set of supervised classification algorithms, a weighted 3-nearest neighbor classifier was selected. A bias force normalization model was introduced in order to make different acquisition sets consistent. Parameters of this model were chosen through a particle swarm optimization method. Additionally, an ex-vivo test was performed to assess the capsule detection performance when magnetically driven along a colonic tissue. Lumps were identified as voltage peaks with a prominence depending on the total magnetic force applied to the capsule. 94% accuracy in hardness classification was achieved, while a 100% accuracy is obtained for the lump detection within a tolerance of 5 mm from the central path described by the capsule. In real application scenario, we foresee our device aiding physicians to detect tumorous tissues.

1 June 2020
Verified
Conference Paper
Closed access
Martina ZaltieriMartina Zaltieri
Martina Zaltieri
JTJoshua Di Tocco
Joshua Di Tocco
Daniela Lo PrestiDaniela Lo Presti
Daniela Lo Presti
Carlo MassaroniCarlo Massaroni
Carlo Massaroni
Domenico FormicaDomenico Formica
Domenico Formica
Maria Sabrina  SartoMaria Sabrina Sarto
Maria Sabrina Sarto
Safety at work is driving the development of new technological solutions in the era of Industry 4.0. Among others, systems able to monitor physiological parameters are gaining high relevance since such devices have the potential to improve the workers' safety. In this perspective, the respiratory rate can provide useful information since it is sensitive to many environmental stressors. In this study, we focused on the development of a test bench to assess the performance of a wearable system for respiratory monitoring. The presented system achieves data collection and synchronization from FBG sensors, a reference flowmeter and, an M-IMU unit. In addition, a GUI has been developed in order to guide the volunteer in the execution of selected movements during the experimental session. The proposed system could further facilitate the design and development of solutions for assessing wearables for workers' activities monitoring.

23 March 2022 in arXiv
Verified
Preprint
Open access
PDF file
LMLuca Massari
Luca Massari
GFGiulia Fransvea
Giulia Fransvea
JDJessica D'Abbraccio
Jessica D'Abbraccio
MFMariangela Filosa
Mariangela Filosa
GTGiuseppe Terruso
Giuseppe Terruso
Calogero Maria OddoCalogero Maria Oddo
Calogero Maria Oddo
Collaborative robots are expected to physically interact with humans in daily living and workplace, including industrial and healthcare settings. A related key enabling technology is tactile sensing, which currently requires addressing the outstanding scientific challenge to simultaneously detect contact location and intensity by means of soft conformable artificial skins adapting over large areas to the complex curved geometries of robot embodiments. In this work, the development of a large-area sensitive soft skin with a curved geometry is presented, allowing for robot total-body coverage through modular patches. The biomimetic skin consists of a soft polymeric matrix, resembling a human forearm, embedded with photonic Fiber Bragg Grating (FBG) transducers, which partially mimics Ruffini mechanoreceptor functionality with diffuse, overlapping receptive fields. A Convolutional Neural Network deep learning algorithm and a multigrid Neuron Integration Process were implemented to decode the FBG sensor outputs for inferring contact force magnitude and localization through the skin surface. Results achieved 35 mN (IQR = 56 mN) and 3.2 mm (IQR = 2.3 mm) median errors, for force and localization predictions, respectively. Demonstrations with an anthropomorphic arm pave the way towards AI-based integrated skins enabling safe human-robot cooperation via machine intelligence.