Currently, the amount of man-made waste worldwide is steadily increasing. It is, therefore, necessary to constantly look for effective ways of utilization and recycling. It is also necessary to reduce the use of non-renewable resources and reduce the impact on the environment. The use of coal industry waste is currently quite insignificant, amounting to some 10% of the total volume. The work aimed to study the properties of raw materials and study the processes of structure formation during the forming, drying, and firing of composite ceramic produced using overburden rock and additives. The work’s relevance lies in the need to solve environmental, economic, and technological problems related to the utilization of coal mining waste. Experiments of the past prove the possibility of using the waste coal industry as additives in the production of building materials. The article presents the results of studies of the chemical, mineralogical, and granulometric composition of overburden rock in coal mining. Peculiarities of structure formation during the forming, drying, and firing of ceramic composites based on optimal fractional compositions from coal-mine overburden were revealed. Organic and chemical additives were used for the correction of technological properties and improvement of the quality of finished composite products. The physical and mechanical indices of the obtained composite ceramic samples were determined, the analysis of which revealed that the use of highly mineralized carbonaceous rocks as solid additives provided a 2–2.5-fold increase in the strength of the product, 5.6% reduction in water absorption, and an increase in the product frost resistance by 20–25 cycles. The aluminum oxychloride influence on the physical and mechanical indices of the obtained composite articles was reflected in a reduction in their water absorption from 8.2 to 7.0%, a 10–12% increase in strength in compression, and an increase in freeze–thaw resistance by 30–35 cycles. Research results proved that the composition and properties of coal-mine overburden rock are close to those of conventional clays. With special technological preparation, they can be used for the production of composite ceramic products. This will significantly reduce the cost of bricks, to make up for the shortage of high-grade clay raw materials and improve the environmental situation. Nevertheless, further research into the use of coal-mine overburdens in the composite ceramic material technology is warranted.
A possible way to solve the problem of energy saving in construction is to introduce energy-efficient buildings at the design stage and, in particular, during retrofit. Therefore, the purpose of this study is to conduct a theoretical analysis of thermal resistance and energy loads on a building in cold climatic conditions. The study of these values was carried out in the ANSYS software package and the Maple computer algebra system, respectively. This study examines four types of structures: the existing facade of a building constructed in 1966, a traditional ventilated facade, and two designs featuring alternating insulation layers with enclosed air channels and with or without heat-reflecting screens in the insulation layer. The results of this study show that the new design incorporating heat-reflecting screens in the insulation layer is 1.15 times more energy-efficient in terms of thermal resistance than the proposed design without such screens. The effectiveness of the proposed new design with heat-reflecting screens in the insulation layer is also confirmed through an analysis of the thermal protection of the building, where the auxiliary indicators, specific characteristics, and complex values of energy efficiency and energy load of the building show greater efficiencies of 1.6, 1.03, and 1.05 times, respectively, compared to the other studied structures. The comprehensive research results presented in this study indicate that the use of energy-efficient wall structures for the retrofit of external enclosures can significantly improve the thermal performance of buildings. It was also determined that the use of such wall structures can significantly enhance the building’s overall energy efficiency rating. The findings of this study highlight that the proposed solutions can contribute to significant energy savings in buildings, while the newly developed structures can serve as valuable additions to the existing catalog of energy-efficient external wall designs.
This paper presents linking computational research of the multilayer structure of the cladding of a three-layer panel made of highly porous polystyrene concrete developed using a new technology in comparison with traditional ones. The calculation of the thermal efficiency of the exterior fence was carried out in three stages, where the thermal regime was calculated from the values of temperature fields in the ELCUT 6.6 system, and the humidity and air modes were determined by the analytical method in the Maple system. The territory of central Kazakhstan (Karaganda) was selected as the research region, where the research showed that equating the thickness by the values of the actual and required heat transfer resistances of traditional multilayer structures to the developed one, the thickness of traditional structures increases from 3.09% to 27.83%. Moisture accumulation relative to the developed one occurs in all the studied structures. Thus, if in some cases of traditional structures moisture is collected by 2.61% and 9.48% less, in others moisture is collected by 27.94% and 119% more. However, the value of evaporated moisture during the drying period showed that all the moisture will evaporate during the specified period. Thus, all the structures meet the conditions for the inadmissibility of moisture for the annual period and the period of moisture accumulation. Moreover, the values of the actual and required permeabilities to air satisfy the condition, which affected the values of the temperature fields taking into account air filtration; the developed structure showed a positive effect for this value, and in traditional structures, the value of decreased to 1.35 °C depending on the option. The analytical results of the thermal inertia values of the developed and traditional multilayer structures showed that the developed structure exceeds traditional ones by up to 30.04% depending on the option, which is positive in the cold period. It was also found that the market prices of all traditional structures exceed the developed one by 1.2–2.5 times, depending on the design, which also emphasizes the positive aspects of the new design. Thus, the findings of this research will positively complement the catalog of products of external multilayer cladding structures made of effective materials and can be used by research communities and design organizations in the design of residential buildings.
1 January 2021 in International Journal of GEOMATE
Theissue of concrete modification of railway sleepers remains relevant in connection with the growing demand for this product and increased requirements for the operational characteristics of one of the basic materials of the track superstructure. The problem is a partial early failure of sleepers, loss of load-bearing capacity in the early periods of operation (in the first years or after ten years).A lot of work has been done in this direction, most of them are aimed at concrete modification, but it is also worth considering the design features of the sleepers, and in order to increase the bearing capacity it is necessary to consider other ways to solve the problem.The aim of the researching was to modify the properties of concrete bypolycarboxylate-basedsuperplasticizers as concrete modifiers, determines their optimal dosages (from 0.8 to 1.1% by weight of cement) in accordance with the physical and mechanical properties of the raw materials and the required concrete workability. The sleepers considered in this article are reinforced with a wire with a diameter of 7 mm (one of the options for enlarged reinforcement). An option for additional reinforcement of sleepers in the area of the rail seat is proposed.Tests were carried out to determine the physical and mechanical properties of raw materials, the strength of concrete, and full-scale tests of the spars for crack resistance in bending were also carried out.The tests were carried out on certified equipment. According to the research results, it was concluded that for the production of sleepers that meet the requirements, it is necessary to use high-quality cements, polycarboxylate-based superplasticizers and additional reinforcement.
14 September 2023 in International Journal of GEOMATE