Reduced deployment and calibration requirements are key for scalable and cost-effective indoor positioning systems. In this work, we propose a low-complexity, weak calibration procedure for an indoor positioning system based on infrastructure lighting and a positioning-sensitive detector. The proposed calibration relies on genetic algorithms to obtain the relevant system parameters in the real positioning environment without a priori information, and requires a low number of simple measurements. The achievable performance of the proposal was assessed by direct comparison with a formal offline calibration method requiring complex dedicated infrastructure and instruments. The comparative error assessment showed that the maximum accuracy reduction compared to the significantly more costly formal calibration was below 25 mm, and the overall absolute positioning error was smaller than 35 mm with orientation errors of around 0.25°. The performance achieved with the proposed weak calibration procedure is sufficient for many indoor positioning applications and largely reduces the cost and complexity of setting up the positioning system in real environments.
The present work proposes a flexible framework for the deployment of real remote laboratories (RRLs). These kinds of laboratory allow students to access hands-on experiences and experiments through an online platform, eliminating the geographical and time constraints associated with traditional on-site laboratories. This innovative approach has proven especially valuable in STEM disciplines (Science, Technology, Engineering, and Mathematics), where hands-on practice and interaction with specialised equipment are critical to learning. In our approach, RRL has been developed for practices in digital electronics and control systems considering multiple practical situations related to distant learning using RRLs accessible through an online booking system. This is an essential tool that allows students to make reservations accessing the practical platform and due to that, it has been integrated into a particular learning management system (LMS) using a separate database online server for greater flexibility and usability. To perform laboratory activities remotely, each RRL instance has local ad hoc hardware that enables the generation and control of different signals letting users to test different practices with the same hardware. The proposed framework can be applied in many knowledge fields and different educational levels for laboratory resource sharing allowing students to receive new teaching technologies online that allow them to use real laboratory equipment avoiding the use of simulations and related constraints to on-site laboratories.
This study unveils a mobile app-based Indoor Positioning System (IPS) tailored for seamless museum navigation. Leveraging smartphone Inertial Measurement Unit (IMU) sensors, it incorporates a Pedestrian Dead Reckoning (PDR) algorithm and a Visible Light Positioning (VLP) beacon-based Angle of Arrival (AoA) algorithm for precise user positioning relative to smart light sources. In standalone mode, the VLP AoA-based algorithm demonstrates reliability with a mean error of 10.64 cm, while the PDR algorithm, operating independently, exhibits mean error of 3 m influenced by environmental factors. Integration of both algorithms proves crucial in mitigating cumulative errors. By updating PDR deviations with the precision provided by the VLP AoA-based solution, the entire system minimizes its mean error to 0.85 m. The user-friendly interface not only enriches visitor experiences with contextual information but also enables intuitive navigation without continuous internet connectivity. This innovative solution caters to the critical demand for precise indoor navigation, particularly in museum environments, fostering increased user acceptance and utilization.
This article investigates the feasibility of a visible-light-based indoor positioning system (IPS) using position-sensitive detectors (PSDs) and commercial luminaires in smoke-filled environments. A dataset comprising 285 measurements was collected over 79 min in a controlled test room, with visibility levels ranging from 3 to 300 m. The system was evaluated under varying smoke densities using visibility as the principal metric, calculated via the Beer–Lambert law and Koschmieder equation. Experimental results show that positioning accuracy degrades with increasing smoke levels, with errors remaining below 270mm even under extreme conditions (visibility ≈3 m). Notably, the system detects signals from emitters outside the nominal field of view (FoV) via multipath reflections, with received power increasing under moderate smoke due to enhanced diffusion. In a challenging scenario—receiver placed 3 m away, behind an obstacle, and under dense smoke—the system maintained signal detection, enabling reliable roomlevel localization. These findings demonstrate the robustness of PSD-based IPSs in adverse environments and highlight their potential for emergency response applications, such as firefighter tracking and evacuation support, where coarse localization is critical.