Intracranial hemorrhage (ICH) resulting from traumatic brain injury is a serious issue, often leading to death or long-term disability if not promptly diagnosed. Currently, doctors primarily use Computerized Tomography (CT) scans to detect and precisely locate a hemorrhage, typically interpreted by radiologists. However, this diagnostic process heavily relies on the expertise of medical professionals. To address potential errors, computer-aided diagnosis systems have been developed. In this study, we propose a new method that enhances the localization and segmentation of ICH lesions in CT scans by using multiple images created through different data augmentation techniques. We integrate residual connections into a U-Net-based segmentation network to improve the training efficiency. Our experiments, based on 82 CT scans from traumatic brain injury patients, validate the effectiveness of our approach, achieving an IOU score of 0.807 ± 0.03 for ICH segmentation using 10-fold cross-validation.
15 October 2021 in IEEE Transactions on Instrumentation and Measurement
The high sensitivity for low-frequency fields makes the tiny giant magnetoresistance (GMR) sensors suitable for high-resolution eddy-current (EC) imaging. In this work, we proposed a novel design of the miniature differential EC probe with a spin-valve GMR sensor for surface and subsurface EC imaging. The differential EC probe consists of a full-bridge GMR chip mounted vertically on the edge of a tiny printed circuit board to reduce the liftoff distance. The excitation signal is perpendicular to the sensing axis of the GMR chip, which makes it sensitive to the unbalance EC signal on the surface of a conductive sample. The miniature EC probe operated at frequencies from 5 to 65 kHz is sensitive to the hidden defects on a flat conductor. The spatial resolution and stability of the device are verified by taking the 2-D scan images over the copper film samples with hidden defects, showing that the spatial resolution is better than 2 mm for the flaw 0.5 mm below the top surface of a multilayer structure. The proposed device is useful in the detection of small surface and subsurface defects, such as cracks, metal loss, and other mechanical damages.
A miniature tri-axis magnetometer with in-plant giant magnetoresistance (GMR) sensors and a fluxguide was designed, implemented and characterized in this work. Three GMR sensor dies were aligned on a printed circuit board (PCB) with their sensing directions in the same plane. By using the flux bending effect of a fluxguide, the magnetic field components in the mounting plane of GMR sensors were generated and hence the effective sensing directions are not in the same plane. The tilt of effective sensing direction from the mounting plane allows the device to detect the out-of-plane field component. When the device was used as an electronic compass, the digitally demodulated sensor outputs were converted into the orthogonal geomagnetic field components by using a real-time conversion process with the voltage-to-field transfer matrix. The result shows that the device is suitable for compass application. Further works to implement the similar design on a CMOS chip with integrated GMR elements and a planar modulation coil will realize a compact and easy-to-fabricate tri-axis magnetic field sensor.
A non-contact current measurement device comprised of a GMR sensor and a ferrite ring core was investigated. The sensor chip employed a high-sensitivity spin-valve full-bridge GMR sensor of which the direct output has non-negligible hysteresis and a limited linear range. By applying an AC modulation current to modulate the output of the GMR sensor, the hysteresis was reduced, and the linear range was over ±0.5 A. The resolution for DC and quasi-static current measurement was 0.1 mA at a 10 Hz bandwidth. The output in proportion to the measured current was obtained either by demodulating the current-sensitive AC signal or by employing the filtered output of the intrinsically nonlinear spin-valve response. The proposed current sensing scheme is suitable for quasi-static current measurement from DC to over 100 Hz.