Yang Gao

Prof. Dr. Yang Gao

Southwest University of Science and Technology, Mianyang, Sichuan, China
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2023 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
ZYZhiqiang Yi
Zhiqiang Yi
WSWeiheng Shao
Weiheng Shao
XTXinxin Tian
Xinxin Tian
Yiqiang ChenYiqiang Chen
Yiqiang Chen
YGYang Gao
Yang Gao
The frequency response and sensitivity of a near-field probe can be improved by using a low noise amplifier (LNA). In this paper, a broadband active dual probe with two LNA is proposed as a high-performance near-field detection tool for the first time. For broadband passive dual probe, a strictly symmetric structure is required. However, the symmetry of the active dual probe is difficult to achieve due to many factors, such as redundant transmission structure and asymmetric LNA chip. Therefore, an asymmetric calibration method (ACM) is adopted to eliminate the effects of the asymmetric structure, which can broaden the operating frequency of the active dual probe. Besides, a characterization method of sensitivity for the active dual probe is presented with an independent source. By analyzing the relationship between the transfer matrix and the physical size (or time delay) of the asymmetric structure, the calibration results of the active probe by using the ACM have been verified. Meanwhile, the sensitivity of this active dual probe is also verified by comparing the calculation and measurement results. Further, by measuring a standing wave, the proposed active probe is broadened to 12 GHz by the ACM.

28 January 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
WRWanchun Ren
Wanchun Ren
JLJintong Li
Jintong Li
GLGuo Li
Guo Li
JCJiarong Chen
Jiarong Chen
SCSi Chen
Si Chen
YGYang Gao
Yang Gao
Magnetic sensors actuated by bulk acoustic wave (BAW) have attracted extensive attention due to the fact of their high sensitivity, GHz-level high frequency, and small size. Different from previous studies, suppression of energy loss and improvement in energy conversion efficiency of the BAW magnetoelectric (ME) sensor were systematically considered during the device design in this work. Finite element analysis models of material (magnetic composite), structure (ME heterostructure), and device (BAW ME magnetic sensor) were established and analyzed in COMSOL software. Additionally, the magnetic composite was prepared by radio frequency magnetron sputtering, and its soft magnetism was characterized by magnetic hysteresis loop and surface roughness. The research results demonstrate that after inserting four layers of 5 nm Al2O3 films, a performance of 86.7% eddy current loss suppression rate, a less than 1.1% magnetostriction degradation rate, and better soft magnetism were achieved in 600 nm FeGaB. Furthermore, compared with other structures, the two-layer piezomagnetic/piezoelectric heterostructure had a better ME coupling performance. Eventually, the design of the BAW ME magnetic sensor was optimized by the resonance-enhanced ME coupling to match the resonance frequency between the magnetic composite and the BAW resonator. When a 54,500 A/m direct current bias magnetic field was applied, the sensor worked at the first-order resonance frequency and showed good performance. Its linearity was better than 1.30%, the sensitivity was as high as 2.33 μmV/A, and the measurement range covered 0–5000 A/m.

8 February 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
SCSi Chen
Si Chen
JLJunru Li
Junru Li
YGYang Gao
Yang Gao
JLJianbo Li
Jianbo Li
HDHongmei Dong
Hongmei Dong
WRWanchun Ren
Wanchun Ren
Implantable medical devices have been facing the severe challenge of wireless communication for a long time. Acoustically actuated magnetoelectric (ME) transducer antennas have attracted lots of attention due to their miniaturization, high radiation efficiency and easy integration. Here, we fully demonstrate the possibility of using only one bulk acoustic wave (BAW) actuated ME transducer antenna (BAW ME antenna) for communication by describing the correspondence between the BAW ME antenna and components of the traditional transmitter in detail. Specifically, we first demonstrate that the signal could be modulated by applying a direct current (DC) magnetic bias and exciting different resonance modes of the BAW ME antenna with frequencies ranging from medium frequency (MF) (1.5 MHz) to medium frequency (UHF) (2 GHz). Then, two methods of adjusting the radiation power of the BAW ME antenna are proposed to realize signal amplification, including increasing the input voltage and using higher order resonance. Finally, a method based on electromagnetic (EM) perturbation is presented to simulate the transmission process of the BAW ME antenna via the finite element analysis (FEA) model. The simulation results match the radiation pattern of magnetic dipoles perfectly, which verifies both the model and our purpose.

18 October 2021 in International Journal of RF and Microwave Computer-Aided Engineering
Verified
Journal Article
Closed access
PDF file
ZYZhiqiang Yi
Zhiqiang Yi
STSha Tang
Sha Tang
JLJiesheng Liu
Jiesheng Liu
WSWeiheng Shao
Weiheng Shao
ESE Shao
E Shao
YGYang Gao
Yang Gao

3 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
XWXiong wang
Xiong wang
WNWang Nantian
Wang Nantian
XXXiaobin Xu
Xiaobin Xu
TZTao Zhu
Tao Zhu
YGYang Gao
Yang Gao
MEMS-based skin friction sensors are used to measure and validate skin friction and its distribution, and their advantages of small volume, high reliability, and low cost make them very important for vehicle design. Aiming at addressing the accuracy problem of skin friction measurements induced by existing errors of sensor fabrication and assembly, a novel fabrication technology based on visual alignment is presented. Sensor optimization, precise fabrication of key parts, micro-assembly based on visual alignment, prototype fabrication, static calibration and validation in a hypersonic wind tunnel are implemented. The fabrication and assembly precision of the sensor prototypes achieve the desired effect. The results indicate that the sensor prototypes have the characteristics of fast response, good stability and zero-return; the measurement ranges are 0–100 Pa, the resolution is 0.1 Pa, the repeatability accuracy and linearity are better than 1%, the repeatability accuracy in laminar flow conditions is better than 2% and it is almost 3% in turbulent flow conditions. The deviations between the measured skin friction coefficients and numerical solutions are almost 10% under turbulent flow conditions; whereas the deviations between the measured skin friction coefficients and the analytical values are large (even more than 100%) under laminar flow conditions. The error resources of direct skin friction measurement and their influence rules are systematically analyzed.

30 January 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
HGHuihui Guo
Huihui Guo
XWXiong wang
Xiong wang
TLTingting Liu
Tingting Liu
ZGZhijiang Guo
Zhijiang Guo
YGYang Gao
Yang Gao
Micro-electromechanical system (MEMS) skin friction sensors are considered to be promising sensors in hypersonic wind tunnel experiments owing to their miniature size, high sensitivity, and stability. Aiming at the problem of short test duration (a few milliseconds) and heavy load in a shock wind tunnel, the fast readout circuit and the sensor head structures of a MEMS skin friction sensor are presented and optimized in this work. The sensor was fabricated using various micro-mechanical processes and micro-assembly technology based on visual alignment. Meanwhile, the sensor head structure was integrated with the fast readout circuit and tested by using a centrifugal force equivalent method. The calibration results show that this sensor provides good linearity, sensitivity, and stability. The measurement ranges are 0–2000 Pa with good performance. The resolution is better than 10 Pa at 3000 Hz detection frequency of the readout circuit for the sensor in ranges from 0 to 1000 Pa. In addition, the repeatability and linearity of static calibration for sensors are better than 1%.