Andreea Trifan

Ms. Andreea Trifan

3D Printing Laboratory, CieH, Carol Davila University of Medicine and Pharmacy, Bucharest, Bucureşti, Romania
+1
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2023 in Materials Chemistry and Physics
Verified
Journal Article
Closed access
ATAdina-Nicoleta Trandaș
Adina-Nicoleta Trandaș
Andreea TrifanAndreea Trifan
Andreea Trifan
AUAndreea-Denisa Ungureanu
Andreea-Denisa Ungureanu
ADAndreea Dusciuc
Andreea Dusciuc
MOMonica Opriș
Monica Opriș
Gabriela IsopencuGabriela Isopencu
Gabriela Isopencu

20 August 2025 in Gels
Verified
Journal Article
Open access
PDF file
Andreea TrifanAndreea Trifan
Andreea Trifan
ELEduard Liciu
Eduard Liciu
ANAndrei Nedelcu
Andrei Nedelcu
MDMihai Dragomir
Mihai Dragomir
DCDoru Daniel Cristea
Doru Daniel Cristea
CBCristina BUSUIOC
Cristina BUSUIOC
Bone defects remain a significant clinical challenge, creating a severe need for advanced biomaterials for tissue regeneration. This study addresses this issue by developing 3D-printed composite hydrogels containing alginate, gelatine, and resorbable calcium phosphates (monetite and brushite) for bone tissue engineering. The scaffolds were fabricated using extrusion-based 3D printing and evaluated for their morphology, porosity, mechanical strength, swelling, degradation, and in vitro mineralization, while their cytocompatibility was assessed using LIVE/DEAD cell viability assays. The key findings demonstrate that calcium phosphate incorporation enhanced the mechanical stability by 15–25% compared to the controls, and mineral deposition increased significantly in the composite scaffolds. The developed hydrogels are bioactive and represent promising, customizable scaffolds for bone regeneration. These results support their further investigation as viable alternatives to traditional bone grafts for clinical bone tissue engineering applications.

Verified
Journal Article
Open access
Andreea TrifanAndreea Trifan
Andreea Trifan
ELEduard Liciu
Eduard Liciu
CBCristina BUSUIOC
Cristina BUSUIOC
Izabela-Cristina StancuIzabela-Cristina Stancu
Izabela-Cristina Stancu
ABAdela Banciu
Adela Banciu
APAlexandru Paraschiv
Alexandru Paraschiv
This research activity proposes to produce composite hydrogel–bioactive glass. The primary purpose of this research is to develop and optimize 3D-printed scaffolds using doped bioglass, aimed at enhancing bone regeneration in bone defects. The bioglass, a bioactive material known for its bone-bonding ability (SiO2–P2O5–CaO–Na2O), co-doped with europium and silver was synthesized and doped to improve its biological properties. This doped bioglass was then combined with a biocompatible hydrogel, chosen for its adequate cellular response and printability. The composite material was printed to form a scaffold, providing a structure that not only supports the damaged bone but also encourages osteogenesis. A variety of methods were employed to assess the rheological, compositional, and morphological characteristics of the samples: Fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM) coupled with energy-dispersive X-ray spectroscopy (EDS). Additionally, simulated body fluid (SBF) immersion for bioactivity monitoring and immunocytochemistry for cell viability were used to evaluate the biological response of the scaffolds.

27 April 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
Andreea TrifanAndreea Trifan
Andreea Trifan
Gianina Popescu-PelinGianina Popescu-Pelin
Gianina Popescu-Pelin
RPRoxana Cristina Popescu
Roxana Cristina Popescu
DCDoru Daniel Cristea
Doru Daniel Cristea
ELEduard Liciu
Eduard Liciu
CBCristina BUSUIOC
Cristina BUSUIOC
One-dimensional fibrous scaffolds with tunable bioactivity offer promise for bone tissue regeneration, yet optimal calcium phosphate phases for enhancing osteogenic perfor-mance remain underexplored. This study aimed to evaluate the impact of monetite, brushite, and cerium-doped phosphates deposition on electrospun nylon nanofibres func-tionalized via matrix-assisted pulsed laser evaporation (MAPLE). Six nylon fibre composi-tions were synthesized, coated with three calcium phosphate phases, calcined at varying temperatures (500–800 °C) before laser deposition. Physicochemical properties were as-sessed using energy-dispersive X-ray spectroscopy (EDX), scanning electron microscopy (SEM), and fibre diameter measurements. Biocompatibility assays following MC3T3 pre-osteoblast seeding and incubation evaluated biological performance. EDX confirmed homogeneous phase deposition; SEM showed phase- and temperature-dependent mor-phology, with monetite yielding uniform granular structures and cerium-doped phos-phate at 800 °C forming dense aggregates. Brushite-coated fibres exhibited superior preos-teoblast metabolic activity versus monetite variants, indicating phase-specific stimulation of bone cells growth. These phosphate-functionalized nylon fibres retain structural integ-rity, hierarchical porosity, and enhanced bioactivity, providing a versatile electrospin-ning-MAPLE platform for customizable bone grafts with clinical potential.

3 June 2026 in Materials
Verified
Journal Article
Open access
PDF file
Andreea TrifanAndreea Trifan
Andreea Trifan
Gianina Popescu-PelinGianina Popescu-Pelin
Gianina Popescu-Pelin
RPRoxana Cristina Popescu
Roxana Cristina Popescu
DCDoru Daniel Cristea
Doru Daniel Cristea
ELEduard Liciu
Eduard Liciu
CBCristina BUSUIOC
Cristina BUSUIOC
One-dimensional fibrous scaffolds with tunable bioactivity offer promise for bone tissue regeneration, yet optimal calcium phosphate phases for enhancing osteogenic performance remain underexplored. This study aimed to evaluate the impact of monetite-, brushite-, and cerium-doped phosphate deposition on electrospun nylon nanofibres functionalised via matrix-assisted pulsed laser evaporation (MAPLE). Five nylon fibre compositions were synthesised, coated with three calcium phosphate phases, and calcined at varying temperatures (500–800 °C) before laser deposition. Physicochemical properties were assessed using energy-dispersive X-ray spectroscopy (EDS), scanning electron microscopy (SEM), and fibre diameter measurements, averaging 62.1±23.8 nm. Biocompatibility assays following MC3T3 preosteoblast seeding and incubation evaluated biological performance. EDX confirmed homogeneous phase deposition; SEM showed phase- and temperature-dependent morphology, with monetite yielding uniform granular structures and cerium-doped phosphate at 800 °C forming dense aggregates. Brushite-coated fibres exhibited superior preosteoblast metabolic activity, reaching 178±2% after 48 h (p < 0.001), indicating phase-specific stimulation of bone cell growth. These phosphate-functionalised nylon fibres retain structural integrity, hierarchical porosity, and enhanced bioactivity, providing a versatile electrospinning-MAPLE platform for customisable bone grafts with clinical potential.

24 April 2026 in Micromachines
Verified
Journal Article
Open access
PDF file
DCDoru Daniel Cristea
Doru Daniel Cristea
ELEduard Liciu
Eduard Liciu
Andreea TrifanAndreea Trifan
Andreea Trifan
CBCorneliu Balan
Corneliu Balan
Extrusion-based bioprinting faces significant challenges in achieving the shape fidelity and internal porosity necessary for cell viability, often hindered by subjective assessment methods. This study investigated the relationship between rheological properties and print quality using a natural polymer biomaterial ink composed of 12% gelatin, 5% alginate, and 1% carboxymethylcellulose. We conducted a comparative analysis between traditional pneumatic systems and screw-driven volumetric extrusion, utilizing a suite of quantitative metrics: Spreading Ratio (SR), Printability Index (Pr), Uniformity Ratio (UF), Collapse Angle (θ), and evaluated porosity. Our results demonstrate that the screw-driven system’s positive displacement mechanism provides superior control over filament morphology by enabling precise volumetric modulation. While the pneumatic system exhibited a high SR of 1.82 and the lowest porosity at 59.92%, the screw-driven system allowed for “under-extrusion” to compensate for viscoelastic die swell. Reducing the flow rate to 50% in the screw system lowered the SR to 1.09, nearly matching the nozzle diameter, and increased porosity to 76.46%. Furthermore, the screw-driven system achieved an ideal Pr of 1.0, whereas the pneumatic system produced distorted, rounded pores with a Pr of 1.57. The findings indicate that screw-driven extruders can decouple line complex rheology from the printing process, allowing for finer spatial resolution and better pore interconnectivity.