Humberto M. Jorge

Humberto M. Jorge

Auto-generated profile, based on publicly available information

Humberto M. Jorge

Department of Electrical and Computer Engineering, University of Coimbra, Coimbra, Portugal

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 June 2017 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
ACAndreia M. Carreiro
Andreia M. Carreiro
HJHumberto M. Jorge
Humberto M. Jorge
Carlos Henggeler AntunesCarlos Henggeler Antunes
Carlos Henggeler Antunes

16 November 2017 in IEEE Transactions on Vehicular Technology
Verified
Journal Article
Closed access
HMHugo Neves de Melo
Hugo Neves de Melo
João Pedro TrovãoJoão Pedro Trovão
João Pedro Trovão
Paulo PereirinhaPaulo Pereirinha
Paulo Pereirinha
HJHumberto M. Jorge
Humberto M. Jorge
Carlos Henggeler AntunesCarlos Henggeler Antunes
Carlos Henggeler Antunes
This paper proposes a comprehensive methodology for the design of a controllable electric vehicle charger capable of making the most of the interaction with an autonomous smart energy management system (EMS) in a residential setting. Autonomous EMSs aim achieving the potential benefits associated with energy exchanges between consumers and the grid, using bidirectional and power-controllable electric vehicle chargers. A suitable design for a controllable charger is presented, including the sizing of passive elements and controllers. This charger has been implemented using an experimental setup with a digital signal processor to validate its operation. The experimental results obtained foresee an adequate interaction between the proposed charger and a compatible autonomous EMS in a typical residential setting.

4 December 2014 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
João Pedro TrovãoJoão Pedro Trovão
João Pedro Trovão
Victor D. N. SantosVictor D. N. Santos
Victor D. N. Santos
Carlos Henggeler AntunesCarlos Henggeler Antunes
Carlos Henggeler Antunes
Paulo PereirinhaPaulo Pereirinha
Paulo Pereirinha
HJHumberto M. Jorge
Humberto M. Jorge
This paper presents an energy management architecture for small urban electric vehicles based on hybrid energy sources and its real-time implementation. The energy management strategy uses an integrated rule-based metaheuristic approach to obtain solutions for sharing energy and power between two sources with different characteristics, namely, one with high specific energy and another with high specific power. A comprehensive real-time architecture for the energy management system is presented considering different management levels. The proposed approach determines an optimized real-time energy sharing between the sources without prior knowledge of the power demand profile. The multilevel energy management strategy has been validated using power-level reduced-scale hardware-in-the-loop simulations for a normalized urban driving cycle. The experimental results show the effectiveness of a real-time implementation based on particle swarm optimization supported by a set of rules restricting the search space. This strategy is effective in controlling the energy sources to work in their higher efficiency region and in satisfying the dynamic performance of the vehicle.

8 May 2018 in International Journal of Sustainability in Higher Education
Verified
Journal Article
Closed access
PFPaula Fonseca
Paula Fonseca
Pedro MouraPedro Moura
Pedro Moura
HJHumberto Jorge
Humberto Jorge
Anibal T. de AlmeidaAnibal T. de Almeida
Anibal T. de Almeida
Purpose: The purpose of this study was to design a renovation plan for a university campus building (Department of Electrical and Computer Engineering) with the aim to achieve nearly zero energy performance, ensuring a low specific demand (lower than 44 kWh/m2) and a high level of on-site renewable generation (equivalent to more than 20 per cent of the energy demand). Design/methodology/approach: The baseline demand was characterized based on energy audits, on smart metering data and on the existing building management system data, showing a recent reduction of the electricity demand owing to some implemented measures. The renovation plan was then designed with two main measures, the total replacement of the actual lighting by LEDs and the installation of a photovoltaic system (PV) with 78.8 kWp coupled with an energy storage system with 100 kWh of lithium-ion batteries. Findings: The designed renovation achieved energy savings of 20 per cent, with 27.5 per cent of the consumed energy supplied by the PV system. This will ensure a reduction of the specific energy of the building to only 30 kWh/m2, with 42.4 per cent savings on the net-energy demand. Practical implications: The designed renovation proves that it is possible to achieve nearly zero energy goals with cost-effective solutions, presenting the lighting renovation and the solar PV generation system a payback of 2.3 and 6.9 years, respectively. Originality/value: This study innovated by defining ambitious goals to achieve nearly zero energy levels and presenting a design based on a comprehensive lighting retrofit and PV generation, whereas other studies are mostly based on envelope refurbishment and behaviour changes.

16 September 2013 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
João Pedro TrovãoJoão Pedro Trovão
João Pedro Trovão
Victor D. N. SantosVictor D. N. Santos
Victor D. N. Santos
Paulo PereirinhaPaulo Pereirinha
Paulo Pereirinha
HJHumberto M. Jorge
Humberto M. Jorge
Carlos Henggeler AntunesCarlos Henggeler Antunes
Carlos Henggeler Antunes
This paper presents a novel energy management strategy for a hybridized power source small urban electric vehicle (EV). First, an analysis of load requirements for typical urban driving cycles is presented. Thereafter, the energy and power management issues are addressed for a multisource EV to define an improved management architecture. A dynamically restricted search space strategy coupled with a simulated annealing technique is exploited to accomplish the global optimization of the energy management system (EMS). The control of the dc/dc converter operations based on this EMS is also presented. The multiple sources have been simulated using an overall model implemented in Matlab/Simulink. A reduced-scale prototype has been built to analyze the performance of the energy management strategy. The results obtained show that energy management has been enhanced leading to an increase of the vehicle performance with reduced size embarked sources.