1 December 2008 in Journal of Magnetic Resonance Imaging
Purpose To assess the ability of adaptive sensitivity encoding incorporating temporal filtering (TSENSE) to accelerate bilateral dynamic contrast‐enhanced (DCE) 3D breast MRI. Materials and Methods Bilateral DCE breast magnetic resonance imaging (MRI) exams were performed using a dual‐band water‐only excitation and a “stack‐of‐spirals” imaging trajectory. TSENSE was applied in the slab direction with an acceleration factor of 2. Four different techniques for sensitivity map calculation were compared by analyzing resultant contrast uptake curves qualitatively and quantitatively for 10 patient datasets. In addition, image quality and temporal resolution were compared between unaccelerated and TSENSE images. Results TSENSE can increase temporal resolution by a factor of 2 in DCE imaging, providing better depiction of contrast uptake curves and good image quality. Of the different methods tested, calculation of static sensitivity maps by averaging late postcontrast frames yields the lowest aliasing artifact level based on ROI analysis. Conclusion TSENSE acceleration combined with 3D spiral imaging is very time‐efficient, providing 11‐second temporal resolution and 1.1 × 1.1 × 3 mm3 spatial resolution over a 20 × 20 × 10 cm3 field of view for each breast. J. Magn. Reson. Imaging 2008;28:1425–1434.
27 January 2022 in NMR in Biomedicine
28 March 2025 in Magnetic Resonance in Medicine
Purpose: To compare 0.55 T and 3 T MRI for imaging patients with titanium total hip arthroplasty (THA). Patients with orthopedic metallic implants often require diagnostic imaging to evaluate adjacent tissues. MRI performance measures, including artifact levels and SNR, vary with field strength. Methods: Six patients with titanium THA were scanned with similar protocols at 0.55 T and 3 T, including proton density (PD) weighted turbo spin echo (TSE), PD TSE with view‐angle tilting (TSE + VAT), PD slice encoding for metal artifact correction (SEMAC), and short tau inversion recovery with SEMAC (STIR‐SEMAC). Images from both field strengths were scored by two readers and qualitatively and quantitatively compared. Results: Diagnostic confidence was significantly higher at 0.55 T compared to 3 T. Perceived metal artifact was substantially reduced at 0.55 T compared to 3 T. At 0.55 T, diagnostic imaging was achieved both without and with multi spectral imaging (MSI) for PD weighted images. Conclusion: Compared to 3 T, 0.55 T MRI offers substantially reduced metal artifacts and higher diagnostic confidence when imaging titanium THA. Advanced multi‐spectral techniques may not be required when the metallic components are entirely titanium.
5 September 2025 in Magnetic Resonance in Medicine
Purpose: Supine breast MRI has the potential to improve over standard prone breast magnetic resonance imaging (MRI) in terms of efficiency and image quality, image alignment with diagnostic and treatment procedures, and overall accessibility. This study aims to characterize potential technical challenges of imaging in the supine position: (i) field inhomogeneities, (ii) variations, (iii) respiratory‐induced breast motion, and (iv) supine breast geometry. Methods: Ten healthy subjects were scanned at 3T in both prone and supine positions to quantify and compare (i) and (ii) between both positions, and to assess (iii) in the supine position. Breast image volumes from a wider population (N = 40, healthy volunteers and patients) were analyzed to obtain breast shape metrics to characterize (iv). Results: field inhomogeneity increased from prone positioning (2SD: ) to supine positioning (2SD: ), and flip angle variations (from prescribed ) were greater in the supine position (2SD ranging to ) than in the prone position (2SD ranging to ). Breast tissue displacement (median [IQR] across all analyzed locations and subjects) was similar along A‐P (1.4 [0.5] mm) and R‐L (1.9 [1.5] mm) directions. Breast geometry varied greatly, with the outer breast perimeter ranging from 34 to 68 cm, and maximum breast tissue thickness ranging from 2 to 9 cm. Conclusion: Supine positioning for breast MRI may lead to greater inhomogeneities and greater variations when compared to prone positioning, and breast motion can be substantial. Breast geometry varies greatly among the female population, and shape metrics can inform supine‐dedicated coil development.
20 June 2026 in Journal of Magnetic Resonance Imaging
Click on the article title to read more.