Qi Liu

Qi Liu

Auto-generated profile, based on publicly available information

Qi Liu

National ASIC System Engineering Research Center, Southeast University, Nanjing, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 March 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
QLQi Liu
Qi Liu
QQQinsong Qian
Qinsong Qian
MZMin Zheng
Min Zheng
SXShengyou Xu
Shengyou Xu
WSWeifeng Sun
Weifeng Sun
TWTingying Wang
Tingying Wang
Four-switch buck-boost (FSBB) converter is widely used in battery applications due to the simple structure and the excellent performance of both voltage step-up and step-down. With the quadrangle control method, FSBB converter can realize zero voltage switching (ZVS) of all power switches, and thus can adapt to the high-frequency trends. However, the conventional quadrangle control method has two problems: 1) the efficiency degradation caused by the large root mean square (RMS) current of the inductor, and 2) the instability caused by the coupling relationship between multiple control variables. In this article, an improved quadrangle control method is proposed to solve the two problems, making FSBB converter a good candidate for high-frequency battery applications. First, the loss analysis is built to determine the relationship between loss and the control variables. Then, the conditions to achieve the minimum loss are obtained. Second, the decoupling compensation strategy is applied to free the coupling relationship to improve the stability. The proposed strategy can achieve three control goals: 1) ZVS of all power switches; 2) minimize the total loss; and 3) stable closed-loop system. Finally, a 1MHz 280W FSBB prototype is built to verify the proposed control method. The prototype achieves all control goals and 98.1% peak efficiency.

9 June 2022 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
QQQinsong Qian
Qinsong Qian
SXShengyou Xu
Shengyou Xu
SXShiyun Xu
Shiyun Xu
QLQi Liu
Qi Liu
SDSong Ding
Song Ding
WSWeifeng Sun
Weifeng Sun
Active clamp flyback (ACF) converter has been demonstrated that which is better than traditional flyback in high-frequency power-adaptor applications. According to the circuit structure, ACF has two modes, primary resonant ACF (PR-ACF) and secondary resonant ACF (SR-ACF). In order to improve the power density, a high-precision primary side regulation (PSR) constant voltage control method for ACF converter is proposed in this paper. The proposed method not only can be effectively adopted in PR-ACF but SR-ACF converter. The high-precision output voltage is predicted by highly accurate sampling points on primary auxiliary voltage. The applied micro controller environment improves the practicability and increases the power density of the ACF system. To verify the proposed PSR method, a prototype which can be changed to PR-ACF and SR-ACF is designed. The output voltage offset, operation efficiency and dynamic performance are analyzed. The tested results show highprecision output is obtained in ACF converter by using the proposed method, the maximum output voltage deviation which are 4% and 3.5% in PR-ACF and SR-ACF converter, respectively. Moreover, SR-ACF has a higher efficiency compared to PR-ACF converter, and a smaller voltage shoot during dynamic process, but which need a larger regulation time since the additional output inductor.

20 August 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
QQQinsong Qian
Qinsong Qian
QLQi Liu
Qi Liu
MZMin Zheng
Min Zheng
ZZZiyan Zhou
Ziyan Zhou
SXShengyou Xu
Shengyou Xu
WSWeifeng Sun
Weifeng Sun
Adaptive synchronous rectification (SR) is a good solution to solve duty cycle loss for LLC resonant converter. Usually, whether the synchronous rectifier is turned off prematurely or late can be detected by whether the body diode is conducted on or not. However, when the switching frequency is below the resonant frequency, both SR turning- off prematurely and late may generate body diode conduction (BDC), which will cause logic errors in the conventional adaptive SR strategy. Then, a large reverse current from load to source will occur, which damages the efficiency. To solve the problem, the time-domain modeling of the SR drain-to-source voltage is established to analyze the mechanism of BDC caused by SR turning- off late. Moreover, an improved adaptive SR driving scheme is proposed, which can identify the two different types of BDC and tune SR to be turned off exactly. Finally, a 280 W LLC prototype is built to verify the established model and the proposed SR method. The prototype proves that both the duty cycle loss and the reverse current are eliminated and efficiency improvement of 0.54% is achieved.

22 January 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
QLQi Liu
Qi Liu
QXQi Xu
Qi Xu
QQQinsong Qian
Qinsong Qian
SDSong Ding
Song Ding
WSWeifeng Sun
Weifeng Sun
The quadrilateral control method for four-switch Buck–Boost converter can enable all of the power switches to achieve zero-voltage-switching (ZVS), thereby achieving high power density. However, the inductor current requires to be sensed and regulated to ensure the realization of ZVS, which will introduce the additional losses and degrade the efficiency. In this article, a high-efficiency control strategy based on lossless current sampling is proposed, which can achieve the minimum height of the inductor current over the whole working conditions. Moreover, to ensure the smooth switching between different modes, a transition mode is inserted when the input voltage is close to the output voltage. Finally, a prototype with input voltage of 40–60V and output parameters of 48V/6A is built to verify the effectiveness of the proposed sampling circuit and control strategy. The peak efficiency is 98.88%, while the full-load efficiency at the nominal input voltage is 98.14%. Meanwhile, a video material is provided to demonstrate the extremely low root mean square (RMS) value of the inductor current and the smooth switching process under different input voltage and load conditions.

22 August 2024 in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
Verified
Journal Article
Closed access
SDSong Ding
Song Ding
ZZZhihong Zhao
Zhihong Zhao
QLQi Liu
Qi Liu
FHFeng Hong
Feng Hong
CNChunyan Nie
Chunyan Nie
BJBaojian Ji
Baojian Ji
Double-clamp zero-voltage-switching (DCZVS) fullbridge flyback converter is one of the most attractive solutions for high power density applications with wide input range, because of its features of primary side regulation (PSR) and excellent softswitching. By analyzing the ZVS process and the maximum output power at maximum flux, this paper reveals that the dead-time is one of the key parameters to restrict the output power of the DCZVS converter at high switching frequency. Then, the multicell transformer-coupled input-series-output-parallel (ISOP) structure is proposed in this paper to shorten the dead-time so as to improve the output power of the DCZVS converter, which does not increase the size of the transformer. In the multi-cell converters, the number of cells and the transformer design are also discussed. Finally, A DCZVS prototype with two transformercoupled ISOP cells is built up to validate the design, which achieves a wide input range of 160V-420V and realizes a 28V/20A output with a power density of 1203 W/inch3 and a peak efficiency of 93.69%. Compared with the original DCZVS converter, the proposed two-cell DCZVS converter achieves a 15% increase in power density with the same transformer size and maximum flux.

21 September 2023 in IET Power Electronics
Verified
Journal Article
Open access
QLQi Liu
Qi Liu
QQQinsong Qian
Qinsong Qian
LSLeilei Shi
Leilei Shi
QXQi Xu
Qi Xu
SDSong Ding
Song Ding
WSWeifeng Sun
Weifeng Sun
Buck converter is a good candidate for the non‐isolated auxiliary power supply (APS) due to its simple structure and high efficiency. However, it can hardly be adopted in applications that required a very high step‐down ratio due to the difficulty to realize an ultra‐low duty cycle, especially when the switching frequency becomes higher and higher. Here, an improved Buck converter is proposed for high‐frequency and high‐step‐down‐ratio APS application. With the control method based on energy extraction, the proposed topology can achieve an ultra‐low equivalent duty cycle. Thus, a high step‐down ratio can be achieved under a high switching frequency. Moreover, the proposed structure can be applied on several types of the main power stage through the power switch sharing technique. Finally, the prototype with the switching frequency of 1 MHz and the step‐down ratio of 18:1 is verified by the experimental results.