Truly wearable, fully flexible, multi-parametric sweat analysis with soft and socially discrete packaging offers tremendous potential to enable the next generation of non-invasive digital biomarkers analysis. Several examples of miniaturized potentiometric ion selective electrodes (ISE) have been proposed. However, several challenges remain unsolved concerning their long-term stability due to variations in physical sweat parameters. We hypothesize that the simultaneous monitoring of such parameters (e.g., skin-surface temperature, sweat rate, and pH) may pave the way for accurate and robust sweat biomarker analysis. Therefore, we propose a flexible multiparameter sensory interface fabricated on Kapton polyimide (PI) foil with high-resolution inkjet printing using silver nanoparticles (AgNPs). A facile controlled drop-casting of a custom synthesized ion-selective membrane ensures the selectivity of the biosensing. Next, we interfaced the fabricated sensory array with a custom-designed compact flexible biosignals conditioning embedded system, which enables system calibration, data processing, and wireless data transmission to a smartphone device. Later, we validate the proposed system in simultaneous sweat multi-ion (K + and Na + ) and skin-surface temperature recording. After that, we characterize the system by embedding the smart medical bracelet in a soft microfluidic platform to mimic in situ analysis on the body. Overall, the reported results represent the fundamental evidence proof for the development of the wearable multimodal sweat parameter analyzer.
27 February 2024 in IEEE Transactions on Instrumentation and Measurement
Dehydration is a frequent condition in the elderly and can lead to serious health complications if not compensated timely. Early diagnosis can be problematic, as medical examinations in hospital would be needed. Fully wearable low-cost multi-sensing devices for home use could help investigate and prevent critical conditions. We introduce a sensing platform designed for operation in remote healthcare for the elderly. It combines a low-cost, highly customizable flexible inkjet-printed multi-sensor bracelet, including sensors for body impedance, skin hydration and temperature monitoring, with a small, low-power front-end circuit and an embedded unit that communicates by a Low Power Wide Area Network (LoRaWAN) transmission interface. We describe individual system components and present in-vitro experiments for their characterization. Reported results represent the fundamental proof of concept for the development of a fully operating device that can be used satisfactorily to monitor dehydration in a real-life application scenario.
In this paper, we present a custom-designed and flexible readout circuitry for the characterization of flexible and planar electrolyte-gated carbon nanotube field-effect transistor-based biosensors for ammonium detection in sweat. We employed spray-deposited semiconducting carbon nanotubes as active material, and functionalized the devices with previously synthesized ion-selective membrane, based on the nonactin ionophore. In the design of the readout circuitry, we focused on enabling low-power operation with a single coin-cell battery with compact wireless data transmission. To maximize the bendability of the flexible PCB, particular attention was taken in layout routing as well as in selecting small- sized packages for the commercial integrated circuits and all-in-one systems such as programmable Bluetooth system- on-chip (i.e., ST microelectronics BlueNRG SoC). We recorded a high sensitivity of 4.516 μA/decade for sweat ammonium level analysis between 0.1 mM to 100 mM, which fully covers the relevant range of interest in the context of sport monitoring. The characterization was carried out with the introduced front-end readout, and the results were benchmarked with a "gold standard" instrument, showing good and reliable performance of the developed fully flexible bioelectronic system.
This paper presents a highly miniaturized and low-power CMOS electrochemical potentiostat based on a fully digital design. The potentiostat functionality has been evaluated through dopamine detection using proper microelectrodes. The system drives an electrochemical cell in a three-electrode configuration and implements the chronoamperometric technique to minimize both power consumption and required area. The circuit has been fabricated using TSMC 180 nm CMOS technology. Supplied at 0.4 V, the potentiostat alone consumes the up-to-date smallest power of 1.2 nW and occupies the up-to-date smallest ever area of 260 μm2. Together with its voltage reference and oscillator, the entire system consumes 9.2 nW and occupies 370 μm2. The potentiostatic voltage maintains an accuracy of ±10% (180 mV to 220 mV) for a 200 mV reference and supply voltage ranging from 0.4 V to 0.56 V, at a frequency of 25 kHz, driven by the ring oscillator. In-vitro experiments demonstrate dopamine detection with a sensitivity of 18.74 pulses/μM and a limit of detection of 0.525 μM. Results demonstrate the huge advantage of using the proposed fully-digital design, making this potentiostat well-suited for implantable devices where size and energy efficiency are critical (e.g., Neural Dust).
Electrochemical sensors integrated with CMOS circuits play a pivotal role in quantifying various chemicals across a huge spectrum of applications, prominently in distributed diagnostics and remote monitoring. When designing integrated devices, meticulous consideration of the electrochemical sensor model becomes imperative, particularly in the CMOS design of electrochemical front-ends. This paper proposes a thorough analysis of the prevalent equivalent circuits for the sensor often considered by CMOS designers, elucidating the substantial limitations inherent in two models largely used and widely recognized in literature. On the other hand, a more comprehensive and precise electrical model is proposed, poised to enhance the robustness of the resulting circuit designs. The comparison between in-vitro measurements and simulation results by considering these three models demonstrates the inherent inaccuracies in the two models conventionally used, while highlighting the improved accuracy of the proposed new electrical model. Using the dopamine detection with a fabricated digital potentiostat as a model example of CMOS design, the conventional electrical equivalent circuits manifest a noteworthy 60% difference in current readings within a sampling time of 600 ms, compared to the measurements, which are instead better followed by the more robust proposed new model. Furthermore, when evaluating saturation risk, the conventional models exhibit a staggering 110% error compared to the measurements and the proposed model.
Malaria continues to pose a significant global health challenge, with substantial impediments arising from the need for more reliable, effective, and economically viable diagnostic tools, particularly for early detection. This research introduces a novel microfluidic device designed for malaria-diagnostics through the detection of hemozoin (Hz), a prevalent biomarker for the disease. Our methodology involves the collection of a minimal blood sample, which is subsequently processed through a microfluidic system. This system exploits the paramagnetic properties of Hz to isolate infected blood cells using magnetophoretic separation. The detection process employs a relative capacitive measurement technique capable of quantifying Hz concentrations ranging from 417 $fM$ to 17 $pM$ , facilitating and enhancing malaria diagnosis. Simulations results confirm the efficacy of our device in providing a rapid, cost-effective, and readily producible diagnostic solution. This research demonstrates the potential of integrating advanced microfluidic technology and sensitive detection systems into a compact, portable unit, offering significant improvements over existing malaria diagnostic tools.