Ji-Hoon Suh

Ji-Hoon Suh

Auto-generated profile, based on publicly available information

Ji-Hoon Suh

School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, South Korea

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 September 2023 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Open access
Song-I CheonSong-I Cheon
Song-I Cheon
HCHaidam Choi
Haidam Choi
HKHyoju Kang
Hyoju Kang
JSJi-Hoon Suh
Ji-Hoon Suh
SPSeonghyun Park
Seonghyun Park
Sohmyung HaSohmyung Ha
Sohmyung Ha
This review article provides a comprehensive overview of impedance-readout integrated circuits (ICs) for electrical impedance spectroscopy (EIS) applications. The readout IC, a crucial component of on-chip EIS systems, significantly affects key performance metrics of the entire system, such as frequency range, power consumption, accuracy, detection range, and throughput. With the growing demand for portable, wearable, and implantable EIS systems in the Internet-of-Things (IoT) era, achieving high energy efficiency while maintaining a wide frequency range, high accuracy, wide dynamic range, and high throughput has become a focus of research. Furthermore, to enhance the miniaturization and convenience of EIS systems, many emerging systems utilize two-electrode or dry electrode configurations instead of the conventional four-electrode configuration with wet electrodes for impedance measurement. In response to these trends, various technologies have been developed to ensure reliable operations even at two- or dry-electrode interfaces. This article reviews the principles, advantages, and disadvantages of techniques employed in state-of-the-art impedance-readout ICs, aiming to achieve high energy efficiency, wide frequency range, high accuracy, wide dynamic range, low noise, high throughput, and/or high input impedance. The thorough review of these advancements will provide valuable insights into the future development of impedance-readout ICs and systems for IoT and biomedical applications.

27 July 2022 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
HCHyungjoo Cho
Hyungjoo Cho
JSJi-Hoon Suh
Ji-Hoon Suh
CKChul Kim
Chul Kim
Sohmyung HaSohmyung Ha
Sohmyung Ha
MJMinkyu Je
Minkyu Je
This paper presents an intra-body power transfer (IBPT) system that can deliver power greater than 1 mW across an on-body distance of 160 cm. A system simulation model is built for the characterization of the channel and optimization of the power transfer. Our system analysis and experimental validation demonstrate that 1 MHz is an optimal carrier frequency for IBPT in terms of power delivered to the load (PDL) and power efficiency (PE). Prototype TX and RX boards were built, and an IC was fabricated in a 180-nm CMOS process for the RX. The proposed RX IC consists of a voltage doubler (VD) and a charge pump (CP) to obtain a sufficiently high voltage conversion ratio (VCR). Among various rectifier topologies, the VD is the optimal topology for the power receiver front-end because the parasitic ground coupling capacitances, which inevitably exist in the IBPT system, act as an inherent input-coupling capacitance for the VD. The implemented VD utilizes a dynamic $V_{TH}$ compensation (DVC) for its diode components. Compared to the conventional static $V_{TH}$ compensation (SVC), DVC in the VD reduces the reverse leakage current of the diode, thus maximizing the power conversion efficiency (PCE) and VCR. In addition, the PDL is enhanced by inserting an inductor on the TX board. It reduces the backward-path impedance without increasing the RX volume, boosting the PDL by up to 9.9 times compared to the PDL without the inductor insertion. The proposed IBPT system delivers up to 178.8 $\mu$W of power at 11.7% of maximum power efficiency with 3.3-V DC output voltage and even 1.385 mW of power with the inductor insertion, supporting various biomedical wearable sensors, such as ECG sensor modules.

14 April 2017 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
JSJi-Hoon Suh
Ji-Hoon Suh
JPJeong-Ho Park
Jeong-Ho Park
Soon-Jae KweonSoon-Jae Kweon
Soon-Jae Kweon
HYHyung-Joun Yoo
Hyung-Joun Yoo
The proposed sensor interface circuit provides an integrative baseline/offset compensation to give higher adaptability and effectiveness for multiparameter sensing microsystems. Capacitive/resistive and voltage type sensors are dealt with and switched-capacitor-based circuits are mostly employed to facilitate integrative baseline/offset cancellation and interface various types of sensors. For integrative signal conditioning, sensor signals are first converted to voltage signals and then given rail-to-rail baseline compensation and fine offset cancellation of 0.7 mV/bit. At the same time, each interface circuit demonstrates a large total conversion gain (C: 194 mV/fF, R: 6260 mV/kΩ, V: 230 V/V) and a coefficient of determination (R 2 ) over 0.998, which indicates a high conversion linearity.

10 April 2023 in IEEE Solid-State Circuits Letters
Verified
Journal Article
Closed access
JSJi-Hoon Suh
Ji-Hoon Suh
HCHaidam Choi
Haidam Choi
YJYoontae Jung
Yoontae Jung
SOSein Oh
Sein Oh
HCHyungjoo Cho
Hyungjoo Cho
MJMinkyu Je
Minkyu Je
Fast neural electrical impedance tomography (EIT) is a promising method to not only record neural activities but also to localize them in peripheral nerves in a minimally invasive way. A much higher image frame rate is required for this application than conventional impedance measurement applications, which generally adopt the I/Q demodulation technique. To achieve a high enough frame rate to capture neural activities along the peripheral nerve fascicle, this paper proposes synchronous sampling (SS) and fast baseline tracking based on successive approximation (SA). The SS method needs an injection of only a single or a few periods of square-wave current signal for the amplitude measurement by synchronously sampling the received voltage signal. The proposed SA-based baseline tracking provides fast signal recovery from unwanted motion artifacts or baseline drifts. The designed readout circuit uses a two-step conversion where its coarse bits are generated from a current-based baseline cancellation circuit and its fine bits from a following SAR ADC. Thanks to the baseline tracking based on the SS and SA, the proposed IC achieves a faster frame rate of 312 fps with continuous baseline update and 500 fps with constant baseline compared to state-of-the-art works. The implemented IC is validated by measuring a water-filled tank and reconstructing its tomographic image. The results show successful discrimination of varied impedance areas over the tank.

17 September 2024 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
HCHaidam Choi
Haidam Choi
Song-I CheonSong-I Cheon
Song-I Cheon
GYGichan Yun
Gichan Yun
SOSein Oh
Sein Oh
JSJi-Hoon Suh
Ji-Hoon Suh
MJMinkyu Je
Minkyu Je
This article presents a bio-impedance (bioZ) readout IC featuring a complex-domain noise-correlated baseline cancellation to overcome the limitation of the conventional baseline cancellation with the real-domain noise correlation. The proposed technique is especially beneficial in cases with significant phase shifts between the excitation current from the current generator (CG) and the input voltage signal produced across the bioZ, through which the CG current flows. This technique employs a tunable reference impedance (TRI) and adaptively adjusts it to match the bioZ in both magnitude and phase, thereby achieving a complex-domain correlation of CG noise. By flowing an identical CG current through both the TRI and bioZ, the noise voltages across the TRI and bioZ caused by the CG current become closely correlated with each other, even in the presence of substantial phase shifts, enabling effective CG noise removal after baseline subtraction. Furthermore, this work proposes a differential-difference current-balancing instrumentation amplifier (DD-CBIA) with quiet chopping for baseline subtraction, offering low power consumption, wide input range, and low input-dependent noise. Measurement results demonstrate significant enhancements in noise performance by a factor of 2.47 and 4.88 for the bioZs with phases of 30° and 60°, respectively, achieving a signal-to-noise ratio (SNR) of 101.5 dB and a figure of merit (FoM) of 150.0 dB. Validation through human-subject experiments using two-electrode configurations on the chest and wrist further supports the effectiveness of the proposed bioZ readout IC.

10 April 2023 in IEEE Solid-State Circuits Letters
Verified
Journal Article
Closed access
HCHyungjoo Cho
Hyungjoo Cho
JSJi-Hoon Suh
Ji-Hoon Suh
GYGichan Yun
Gichan Yun
Sohmyung HaSohmyung Ha
Sohmyung Ha
MJMinkyu Je
Minkyu Je
In this letter, we present an intra-body-power-transfer (IBPT) system that delivers power greater than 100 μW even across a 150-cm on-body distance. The proposed IBPT TX employs an FLL-based maximum-resonant-power-tracking (MRPT), which runs in the background to maximize the power delivered to the load (PDL). The proposed technique does not require any RX-to-TX back telemetry or searching phase, thus enabling uninterrupted power delivery. The PDL and power transfer efficiency are further improved by inducing parallel resonance at RX. Fabricated in a 180-nm BCD process, the proposed IBPT system achieves 136-μW PDL at 1.8-V DC output with 8.83% end-to-end power efficiency.