16 April 2018 in Journal of Materials Chemistry C
Strain sensors with a broad sensing range, high sensitivity and linearity are highly desirable in health monitoring systems to detect both large and subtle strains. However, few strain sensors demonstrate the same high sensitivity at both large strain and subtle strain. In this work, we report a highly linear and broad-range-detection strain sensor by designing a fin-like microstructure, which combines the advantages of vertical carbon nanotubes (CNTs) and Ecoflex. In the proposed structure, most of the vertically grown CNTs are wrapped by polymer to form the CNT–Ecoflex Nanofin (CEN) matrix, while some of the vertical CNTs at the edge of the CEN protrude, like spines on the fin. These exposed CNT spines can effectively improve the sensitivity, especially to small strain. In the CEN structure, the Ecoflex resists the shifting and breaking of CNTs under cyclic strains, which ensures the stretchability and reliability. The unique CEN structure enables the sensor to obtain excellent linearity (R2 > 0.99) under the strain range of 0 to 250% and high sensitivities (from 3 to 18) within a wide sensing range (from 0.1% to 500%). Most importantly, the specification of the strain sensors can be tuned by controlling the lengths and densities of CNTs. These virtues endow the sensor with great application prospects in wearable electronics and health monitoring.
1 March 2021 in Annals of Translational Medicine
Background: Due to the special anatomy morphology and physiological function of the mandible, it has always become a challenge to accurately reconstruct the mandibular defect in maxillofacial surgery. Digital three dimensions (3D) printing surgical guide, as the effective method for individual and accurate surgery, is a hotspot of clinical research at present. In this study, 3D printing PLA surgical guide plate was applied to reconstruct the mandibular defect with fibula flap, its clinical effect and accuracy were evaluated, which aimed to improve the accurate reconstruction of mandibular defects. Methods: After sterilization, the dimension deformation of the PLA standard specimen were measured. Eighteen patients diagnose with mandibular tumor were collected as observation objects. Then partial mandible resection and simultaneous mandible reconstruction with fibula graft were implemented according to the computer-aided design plan. The clinical effects of 3D printing PLA guide plates application were evaluated by facial contours, occlusal stability and chewing function. Through registering the postoperative computed images reconstruction with preoperative designed shape, the reconstruction accuracy was evaluated by detecting the maximum difference including the distance between lateral convex point of the condyles, the distance between medial convex point of the condyles and the horizontal contained angle between long axis of the condyles. Results: After high temperature steam sterilization, the curvature of the PLA specimen with 100% filling rate and 4.8 mm thickness were the smallest and their dimension deformation had no statistical significance (P>0.05). The minimally deformed 3D printing PLA guide plate were smoothly placed in the right place during the operation. After surgery, the face was symmetrical, the occlusal relationship was restored well and no deviation of the mandibular movement were found. The spiral computed tomography (SCT) scanning showed that the distance between lateral/medial convex points of the condyle and the horizontal contained angle were 128.34±8.68 mm, 88.69±6.75 mm and 145.87°±12.01°. Compared with preoperative design, the maximum deviation of the actual postoperative registration was 1.67±0.63, and the difference was not statistically significant (P>0.05). Conclusions: The application of 3D printing PLA guide plate in the segmental section and reconstruction of the mandible can effectively simplify the operation, and better reconstruct the continuity of the mandible. The surgical accuracy can fully meet clinical needs with relatively low prices.
10 September 2020 in RSC Advances
A pressure sensor design suitable for a broad sensing range with high sensitivity and good stability is highly desirable for the detection of various pressures and meeting the requirements of different applications. Herein, we report sensing-range-tunable piezoresistive pressure sensors realized by self-patterned-spacer design. In the sensors, the two CNT-array layers embedded in PDMS are separated by the proposed self-patterned spacer. With this structure, the realized sensors with large initial resistance designed show tunable response thresholds from 300 Pa to 6.5 kPa while maintaining high sensitivity, which are realized by controlling the spacer thickness and the CNT length. Besides, the vertical CNT arrays have a large specific surface area, which can dramatically change the resistance of the pressure sensors and lead to high sensitivity with nearly 50 kPa−1. Benefiting from the designs of the self-patterned spacer and the advantageous combination of CNTs and PDMS, the pressure sensors also exhibit a rapid response/relaxation time of 24/32 ms, and good long-term stability with durability test over 10 000 loading/unloading cycles. On the other hand, the realized pressure sensors with small initial resistance designed show a typical piezoresistive characteristic. For applications, the pressure sensors with large initial resistance designed are suitable for the anti-noise applications with pressure thresholds to filter unnecessary noise and save power consumption, while the pressure sensors with small initial resistance designed show the capability of detecting mechanical forces and monitoring human physiological signals. Moreover, the self-patterned design and fabrication method of the spacers also show potentials to be applied in the existing works to further enhance or adjust the performance of those pressure sensors, showing great flexibility. This design demonstrates great potentials to be applied in future advanced flexible wearable systems such as health monitoring, human–machine interaction and the Internet of Things.
14 January 2019 in IEEE Electron Device Letters
Amorphous indium gallium zinc oxide (a-IGZO) thin film transistors (TFTs) with high mobility are highly desirable to achieve high-speed operation in active-matrix displays and largearea sensors. Only a few works provided potential solutions. In this work, we have embedded carbon nanotubes (CNTs) into sputtered a-IGZO film to form a-IGZO/CNT/a-IGZO (ACA) sandwiched channel. In the ACA channel, the CNT percolation networks connected by the a-IGZO film work as high-speed carrier paths to enable faster transport of carriers during the on state while it does not degrade the leakage performance during the off state. The type and the embedding location of the CNT percolation network are critical to determine the ACA device performance, which is analyzed and verified by experiment and simulation. The optimum ACA design has approximately doubled the mobility and the on current density of the TFT. The design owns relatively better uniformity and provides a high-speed TFT solution for the advanced electronics.
13 December 2018 in Korean Journal of Chemical Engineering
Chemical looping air separation gives an oxygen resource for the oxy-fuel combustion system. To investigate the sensitivity of operation parameters and optimal operation parameters, with the consideration of the reactor temperature, we used the oxygen concentration, and reaction gas flow, an orthogonal experiment and multi-objective comprehensive evaluation method to analyze the results obtained by fixed-bed apparatus with the YBaCo4O7+δ, Y0.95Ti0.05BaCo4O7+δ, Y0.5Dy0.5BaCo4O7+δ, and Y0.2Ti0.05Dy0.75BaCo4O7+δ oxygen carriers. The results showed that the effects of operating conditions on oxygen absorption/desorption properties varieds in the order: oxygen concentration>gas flow rate>absorption temperature=desorption temperature. Analysis of max-min difference showed that the optimum operating conditions such as absorption temperature, 350 °C, desorption temperature, 430 °C, gas flow rate, 200 ml/min, and oxygen concentration, 21% were confirmed.