16 April 2018 in IEEE Journal of Selected Topics in Quantum Electronics
A novel approach is developed for measuring small losses in highly transparent Si3N4/SiO 2 waveguides on a silicon chip. The approach is particularly applicable to waveguides written by high-resolution patterning techniques, such as e-beam lithography, whose lengths cannot be easily increased beyond several centimeters. This method is based on measuring the transmission of an optical cavity formed by two highly reflective (R at least 0.999) simple Bragg gratings and a uniform waveguide between the two gratings whose length can be varied to increase the loss fitting accuracy. A theoretical model based on an ABCD matrix method is developed and used for the final loss value fitting. Experimentally, a cavity with extinction ratio over -70 dB and quality factor Q = 1.02×10 6 is realized. The fitting results show a waveguide loss of 0.24 ± 0.01 dB/cm and a grating loss of 0.31 ± 0.01 dB/cm. These results are obtained with relatively high index contrast (Δn > 0.001) gratings with 0.1-pm wavelength scanning resolution. It is expected that with better design and wavelength scanning technique, this approach is applicable more generally to measure waveguide loss coefficients as low as 0.001 dB/cm.
6 May 2020 in Journal of Lightwave Technology
We report the design and characterization of a high performance integrated arbitrary filter from 1450 to 1640 nm. The filter's target spectrum is chosen to suppress the night-sky OH emission lines, which is critical for ground-based astronomical telescopes. This type of filter is featured by its large spectral range, high rejection ratio, and narrow notch width. Traditionally it is only successfully accomplished with fiber Bragg gratings. The technique we demonstrate here is proven to be very efficient for on-chip platforms, which can bring many benefits for device footprint, performance, and cost. For the design part, two inverse scattering algorithms are compared, the frequency domain discrete layer-peeling (f-DLP) and the time domain discrete layer-peeling (t-DLP). f-DLP is found to be superior for the grating reconstruction in terms of accuracy and robustness. A method is proposed to resolve the non-uniformity issue caused by the non-zero layer size in the DLP algorithm. The designed 55-notch filter is 50-mm-long and implemented on a compact Si 3 N 4 /SiO 2 spiral waveguide with a total length of 63 mm. Experimentally, we demonstrate that the device has a insertion loss as low as 2.5 dB, and that the waveguide propagation loss is as low as 0.10 dB/cm. We are also able to achieve uniform notch depths and 3-dB widths of about 28 dB and 0.22 nm, respectively.