Upekha Delay

Upekha Delay

Auto-generated profile, based on publicly available information

Upekha Delay

School of Electrical and Computer Engineering, Cornell University, Ithaca, NY, USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 July 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
UDUpekha Delay
Upekha Delay
TNThoshara Nawarathne
Thoshara Nawarathne
SDSajan Dissanayake
Sajan Dissanayake
SGSamitha Gunarathne
Samitha Gunarathne
TWThanushi Withanage
Thanushi Withanage
JWJanaka Wijayakulasooriya
Janaka Wijayakulasooriya
Fetal movement count monitoring is one of the most commonly used methods of assessing fetal well-being. While few methods are available to monitor fetal movements, they consist of several adverse qualities such as unreliability as well as the inability to be conducted in a non-clinical setting. Therefore, this research was conducted to design a complete system that will enable pregnant mothers to monitor fetal movement at home. This system consists of a non-invasive, non-transmitting sensor unit that can be fabricated at a low cost. An accelerometer was utilized as the primary sensor and a micro-controller based circuit was implemented. Clinical testing was conducted utilizing this sensor unit. Two phases of clinical testing procedures were done and during the first phase readings from 120 mothers were taken while during the second phase readings from 15 mothers were taken. Validation was done by conducting an abdominal ultrasound scan which was utilized as the ground truth during the second phase of the clinical testing procedure. A clinical survey was also conducted in parallel with clinical testings in order to improve the sensor unit as well as to improve the final system. Four different signal processing algorithms were implemented on the data set and the performance of each was compared with each other. Out of the four algorithms three algorithms were able to obtain a true positive rate around 85%. However, the best algorithm was selected on the basis of minimizing the false positive rate. Consequently, the most feasible as well as the best performing algorithm was determined and it was utilized in the final system. This algorithm have a true positive rate of 86% and a false positive rate of 7% Furthermore, a mobile application was also developed to be used with the sensor unit by pregnant mothers. Finally, a complete end to end method to monitor fetal movement in a non-clinical setting was presented by the proposed system.

13 May 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ESEranda Somathilake
Eranda Somathilake
UDUpekha Hansanie Delay
Upekha Hansanie Delay
JSJanith Bandara Senanayaka
Janith Bandara Senanayaka
SGSamitha Lakmal Gunarathne
Samitha Lakmal Gunarathne
RGRoshan Godaliyadda
Roshan Godaliyadda
CRChathura Rathnayake
Chathura Rathnayake
Assessing the health of both the fetus and mother is vital in preventing and identifying possible complications in pregnancy. This paper focuses on a device that can be used effectively by the mother herself with minimal supervision and provide a reasonable estimation of fetal and maternal health while being safe, comfortable, and easy to use. The device proposed uses a belt with a single accelerometer over the mother’s uterus to record the required information. The device is expected to monitor both the mother and the fetus constantly over a long period and provide medical professionals with useful information, which they would otherwise overlook due to the low frequency that health monitoring is carried out at the present. The paper shows that simultaneous measurement of respiratory information of the mother and fetal movement is in fact possible even in the presence of mild interferences, which needs to be accounted for if the device is expected to be worn for extended times.

22 January 2024 in IEEE Sensors Letters
Verified
Journal Article
Closed access
ZZZijing Zhang
Zijing Zhang
JZJianlin Zhou
Jianlin Zhou
TCThomas Conroy
Thomas Conroy
XHXiaonan Hui
Xiaonan Hui
PSPragya Sharma
Pragya Sharma
Edwin C KanEdwin C Kan
Edwin C Kan
Near-field radio sensors can be implemented both as wearables for continuous monitoring and as furnishing attachments for covert operation, without requiring skin touch, enabling convenient deployment and high user comfort. The sensor can output cardiac and respiratory waveforms, systemic pulses, muscle contraction, eye movement, and tissue vibration for various biomedical, biological, and cyberphysical applications. The radio signal can go through layers of fabrics or animal surface coverings with little loss or dispersion to couple directly inside the living body. We will illustrate the theory, design variations, and verified results, and discuss present limitations and outlooks for technology adoption in practical scenarios.

1 June 2026 in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
Verified
Journal Article
Closed access
UDUpekha H. Delay
Upekha H. Delay
ZZZijing Zhang
Zijing Zhang
Edwin C KanEdwin C Kan
Edwin C Kan
This paper explores the air writing application of radiomyography (RMG), a near-field radio frequency (NFRF) sensing modality, and studies the key issues in human-computer interaction (HCI), including user acceptability and privacy concerns. Our primary objective is to demonstrate the efficacy of our NFRF sensing system in identifying both handwritten characters and the writer. We employed a forearm-worn multiple-input-multiple-output (MIMO) RMG to capture the detailed actuation of superficial and deep muscles during the air writing motion through enhanced electromagnetic coupling in the near-field. The sensing architecture leverages synchronized software-defined radios (SDRs), custom antenna arrays, and frequency-division multiplexing to enable precision muscle activity detection in a wearable armband. Various signal processing and machine learning (ML) algorithms were benchmarked for both classification accuracy and computational efficiency. The experimental study included 26 letters and 25 writers. The best performing algorithm achieved an average character classification accuracy of 92.35% (95% CI: 90.06–94.64). Moreover, through transfer learning, our model reached 95% testing accuracy in character classification for new subjects using just 10% of the available data for training. The writer identification model achieves an average accuracy of 99.1%, including longitudinal studies. These results highlight the promise of forearm-worn RMG as a novel HCI alternative, offering accurate performance without the need for cumbersome devices on the hand that may obstruct dexterity or the need for wet body-contact electrodes in surface electromyography.

1 January 2026 in IEEE Access
Verified
Journal Article
Open access
AKAakash Kapoor
Aakash Kapoor
UDUpekha Delay
Upekha Delay
KGKapil Gangwar
Kapil Gangwar
Edwin C KanEdwin C Kan
Edwin C Kan