Near-field radio sensors can be implemented both as wearables for continuous monitoring and as furnishing attachments for covert operation, without requiring skin touch, enabling convenient deployment and high user comfort. The sensor can output cardiac and respiratory waveforms, systemic pulses, muscle contraction, eye movement, and tissue vibration for various biomedical, biological, and cyberphysical applications. The radio signal can go through layers of fabrics or animal surface coverings with little loss or dispersion to couple directly inside the living body. We will illustrate the theory, design variations, and verified results, and discuss present limitations and outlooks for technology adoption in practical scenarios.
Phase-based 3-D localization of radio-frequency (RF) markers has high sensitivity and accuracy. However, phase measurements suffer from oscillator phase noises, wavelength ambiguities, and multipath interferences. Additionally in the near field, antenna detuning and medium inhomogeneity render the phase-distance relation nonlinear and nonmonotonic and bring forth extra ambiguities, especially with obstructed Line-of-Sight (LoS). In this work, we present a novel precision localization framework which leverages spatially diverse redundant channels to resolve ambiguities without relying on broad bandwidth. First, measured differential phases were used to accurately retrieve differential distances from spline-fitted phase-distance curves. Then, distances from multiple channels were combined to generate 3-D location estimates. Finally, location ambiguities were removed by taking different channel subsets to identify one unambiguous location using spatial clustering. An experimental multiple-input–multiple-output (MIMO) network was implemented by a Universal Software Radio Peripheral (USRP) platform and harmonic RF markers to demonstrate millimeter-level 3-D localization at sub-1GHz carrier frequencies within heavy multipath ambient, simulating the condition inside building structures.
Many respiratory disorders are diagnosed by lung function tests, typically performed using spirometers in clinical settings. Noninvasive measures of lung function are of increasing interest to enable convenient, at-home wellness monitoring of respiratory distress. In this work, we used near-field radio frequency (NFRF) sensors on mechanically ventilated porcine models for the continuous acquisition of pulmonary dynamics for each lung independently under various cardiopulmonary interventions. NFRF sensors, previously shown to detect internal tissue motion, were deployed laterally across the pig’s chest to measure tidal volume during a stepped intervention. A reference spirometer was used for validation. We used bronchial blockers to isolate each lung, allowing us to demonstrate the novel capability of individually monitoring lung volumes. We demonstrated lung volume measurements with an average error of 9.2% between NFRF and reference spirometry. We also showed individual lung dynamics during one-lung obstruction. The results of this work demonstrate NFRF sensors as a novel wearable method for continuous monitoring of individual lung volumes, aiding the management of respiratory distress during acute and chronic conditions, as well as for detecting the early onset of life-threatening conditions such as pneumothorax.
This paper presents a pilot study to detect restlessness and respiratory distress (RD) in patients living with dementia (PLWD) using a bed-embedded near-field radio-frequency (NFRF) sensor. We recruited 10 PLWD from Weill Cornell Medicine and deployed an NFRF bed sensor and concurrently recorded patient video for 48-hours to monitor for restlessness and RD. Physiological features were extracted from the thoracic and abdominal sensors, which included breathing rates, heart rates, activity levels, and paradoxical breathing patterns. We used annotations of restlessness and RD from the video recordings as references to build our models. Machine learning (ML) models were employed to distinguish an intentional action from non-purposeful movements (i.e., restlessness) by including variance, mobility, and complexity measures. We assessed for RD by using a validated clinical scale, the Respiratory Distress Observation Scale (RDOS), and also examined cough as a special class. Data augmentation was applied to mitigate high class imbalance, particularly for higher RDOS scores. Random forest, K-nearest neighbors (KNN), and neural networks (NN) achieved acceptable performance in k-fold cross-validation (CV), although accuracy declined under leave-one-participant-out (LOPO) analysis due to inter-patient variability. Results indicate that the NFRF sensor combined with ML can provide a promising tool for automated detection of patient restlessness and RD. Patient-specific calibration will be required for robust deployment in clinical practice. Caregiver surveys reported high acceptance without any adverse events to patients, and a recognition of its potential for timely detection of breathing-related issues.