1 January 1993 in Medical & Biological Engineering & Computing
A gaseous oxygen sensor is described based on the measurement of phosphorescence lifetime of the dye palladium coproporphyrin, immobilised in a range of membrane materials including polyvinyl chloride, polymethylmethacrylate, polystyrene and silicone rubber. The lifetime of the dye in these materials is described, measured using a simple system consisting of a pulsed xenon flash lamp light source and a PC-based data acquisition system. The linearity of the sensing membranes over the 0–100 per cent oxygen range is presented together with data on temperature sensitivity, the effects of CO2, N2O, H2O and halothane, and the effects of ageing over a 90 day period. The sensors based upon polystyrene immobilised dye appear to provide the optimum characteristics for a gaseous oxygen sensor.
1 January 2014 in BioMedical Engineering OnLine
There are several ways to measure the respiratory system, among them inductance plethysmography and three-dimensional kinematic analysis, methods of high cost and difficult transportability. The objective of this study was to correlate respiratory volumes obtained by spirometry standard equipment with a biomechanical model photogrammetric analysis of adolescents. We evaluated 50 subjects of both genders, aged between 14 and 17 years old, excluding those with respiratory obstruction or restriction. Stickers with markers, there was a five-point mapping for anatomical modeling and photogrammetry, with each evaluated in supine position, was sought to test the Forced Vital Capacity (FVC). The test was filmed and repeated three times. Images of the films were extracted for the moment of maximum exhalation and inhalation of proof with better breathing. With the use of a commercial software, defined the respiratory volumes to the thorax and abdomen. The photogrammetric analysis has found values strongly correlated with the spirometric measurements of FVC (0.812), forced expiratory volume in one second (FEV1 – 0.708), Peak Expiratory Flow (PEF – 0.762) in addition to post test performed Inspiration (IP- 0.816). There was a higher ventilatory mobility for boys than girls for Lower Chest and Lower and Upper Abdomen. It was possible to reach a regression R2 = 0.866 for proof of FVC and R2 = 0.776 for IP with the use of photogrammetry, presenting a standard error of 0.353 and 0.451, respectively. Photogrammetry can be used to study thoracoabdominal movements by applying analytical two-dimensional and three-dimensional images acquired using a video camera being, applicable and reproducible.
4 March 2020 in IEEE Sensors Journal
Aluminum alloys are mainly used to manufacture automated machinery and in aeronautic, automotive, and biomedical structures, as well as tools for functions requiring strength, lightness, and precise movements. Monitoring and characterization of this material is very important to guarantee quality for those structures. This study proposes a new methodology for nondestructive testing and characterization of these materials using attenuation of ultrasonic waves and electrical impedance of piezoelectric ceramic plates attached to aluminum alloy bars. Five solid aluminum bars measuring 250 mm × 50 mm × 50 mm were used; in four, three holes of varying diameters and depths were drilled to simulate defects, while one bar was left intact as a reference. Three piezoelectric ceramic plates measuring 12.7 mm x 12.7 mm × 0.52 mm were attached to each bar near the manufactured defects and at the same position in the reference sample. Electrical impedance was assessed, and attenuation of the ultrasonic waves was measured using a function generator to excite the ceramic plates with a single 20 Vpp sine pulse in transmit/receive and pulse-echo modes at 90, 145, 230, and 376 kHz. Broadband attenuation was assessed using two pairs of transducers with nominal center frequency of 500 kHz and 5 MHz. The signals were acquired using a Tektronix TDS2022 digital oscilloscope and then processed in MATLAB. The results showed the viability of this technique for identifying defects in metallic aluminum structures and characterizing these materials using lower frequencies.
1 January 2010 in Research on Biomedical Engineering
LOLutero Marques Oliveira
WPWagner Coelho Albuquerque Pereira
Wagner Coelho Albuquerque Pereira
1 June 2009 in Sba: Controle & Automação Sociedade Brasileira de Automatica
Este trabalho apresenta um sistema de geração, aquisição e processamento de sinais de ultra-som para caracterização de materiais. O sistema permite operação nos modos pulso-eco e transmissão-recepção, com taxa de amostragem configurável entre 5 MHz e 80 MHz, sincronismo interno, taxa de repetição dos pulsos de excitação dos transdutores entre 111 Hz e 333 Hz, largura do pulso de 100 ns e amplitude de 200 V. Os circuitos de recepção operam na faixa entre 20 kHz e 30 MHz, com controle de ganho entre -40 dB e +40 dB. Para avaliar o desempenho do sistema, foram realizadas medidas de velocidade de propagação e atenuação em banda larga de ondas ultra-sônicas BUA em acrílico e água. Os resultados obtidos apresentaram desvios inferiores a 1 %, evidenciando que o sistema apresenta boa repetitividade e pode ser utilizado em testes não invasivos e não destrutivos para caracterização de diferentes materiais.