Scanning spreading resistance microscopy (SSRM) has recently celebrated 30 years of existence when counting from the original patent of 1994. In this time, the technique has experienced an incredible journey with substantial evolutions that transformed SSRM from a small-scale experiment into a staple for chip manufacturing laboratories for physical analysis of materials, failure analysis, and process development of integrated circuits. As the nanoelectronics industry is ready for a new inflection point, with the introduction of nanosheet field-effect transistor to replace FinFETs and cell track scaling architectures such as the complementary field-effect transistors, SSRM is once again at a turning point. This review aims to highlight the state-of-the-art while discussing the emerging challenges introduced by the ever-increasing complexity in complementary metal–oxide–semiconductor (CMOS) manufacturing. We start by illustrating the unique capability of the SSRM technique, its origin, and its evolution. Next, we continue by showing the considerable research effort that enabled SSRM to transition to a tomographic sensing method in support of FinFET transistors. Here, the high aspect ratio fin geometry and the complex contacts technology have imposed important modifications to the original method. Later, we elaborate on some of the key challenges introduced by the upcoming device transition from three-sided channel FinFETs into nanosheet FETs, i.e., offering a four-sided electrostatic control of the channel. Finally, we present the use of machine learning for automation in carrier calibration with increased accuracy. We close by introducing some of the concepts that we consider promising for further extension of SSRM to obtain sub-nm structural information and doping profiles in the area of advanced FinFETs and nanosheet FET technologies, including (a) correlative analysis flow, (b) liquid-assisted probing, and (c) top–down and bottom–up multi-probe sensing schemes to merge low- and high-pressure SSRM scans.
Ferroelectrics show promise for low‐power, non‐volatile memory technologies. However, material challenges in state‐of‐the‐art ferroelectric hafnates and the high coercive fields required limit their application in devices. Scaling of other candidate materials is challenging, often requiring epitaxial single‐crystalline growth using specialised substrates. Here, ferroelectricity is demonstrated in polycrystalline BaTiO3 films at 10 nm thickness on Si substrates. They exhibit the highest reported remnant polarization for polycrystalline layers, 13 µC cm−2, a value that is competitive with the epitaxial BaTiO3 state‐of‐the‐art. This is realised by introducing a novel conductive oxygen barrier, platinum silicide, which also offers strain enhancement of the ferroelectricity. Moreover, it is demonstrated that these layers can be positioned in device‐like stacks whilst maintaining ferroelectricity at 10 nm. The findings of polycrystalline perovskite ferroelectric growth in stack configurations akin to those in production flows paves the way for high performance perovskites with greater material complexity.
26 June 2023 in IEEE Transactions on Electron Devices
A new compact model, incorporating bias-dependent Schottky barrier height (SBH), is developed to precisely describe the forward-biased current–voltage characteristic of electrical contacts to Ge and GaAs layers in active silicon photonic (SiPho) components. This generic model enables direct evaluation of both the contact doping concentration and the effective barrier height of any semiconductor diode with a single-sided Schottky contact. Extracted parameters greatly agree with scanning spreading resistance microscopy (SSRM) results and literature reports. Process variabilities and design impacts were studied, and insights brought by the model enlightens future device improvements to realize Ohmic contacts.
The quick tip exchange capability of reverse tip sample (RTS) scanning probe microscopy (SPM) provides significant efficiency benefits over conventional SPM, especially in high-force modes like scanning spreading resistance microscopy (SSRM). While prior developments in RTS SSRM have addressed conductive diamond probe chip fabrication, sample preparation for electrical SPM measurements, and qualitative measurement capabilities, the challenge of achieving quantitative carrier profiling remained unresolved, primarily due to focused ion beam (FIB) damage that is introduced during RTS sample preparation. In this work, we present two different FIB-based RTS sample preparation protocols for mounting multiple samples on a single tipless cantilever. The core postulation is that co-mounting the target and calibration samples together ensures that they undergo identical ion beam exposure, thereby enabling accurate SSRM quantification. The first protocol employs sequential mounting of individual samples, while the second involves bonding the samples together, polishing their surfaces, and then, mounting them as a single, unified assembly. It is also worth noting that the latter protocol supports a sample layout that enables quantitative analysis to be done on each individual scanline, which can reduce the impact of measurement artefacts resulting from tip degradation or just unstable tip-sample contact during scanning. Quantitative validation of RTS SSRM for both preparation protocols was accomplished by implementing two different staircase calibration samples, comprised of layers having well-defined carrier concentrations. Finally, mounting a calibration sample alongside an actual device sample confirmed that RTS SSRM delivers results equivalent to those obtained with conventional SSRM, affirming its quantification reliability for practical applications. By establishing quantitative SSRM in RTS configuration, this work addresses a critical gap and further positions RTS SPM as a valuable approach for advancing electrical SPM characterization.