Wenzhi Zhou

Wenzhi Zhou

Auto-generated profile, based on publicly available information

Wenzhi Zhou

Centre for E-Mobility and Clean Growth, Coventry University, Coventry, U.K.

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 June 2021 in IEEE Access
Verified
Journal Article
Open access
XYXu Yipu
Xu Yipu
Xibo YuanXibo Yuan
Xibo Yuan
FYFei Ye
Fei Ye
ZWZihao Wang
Zihao Wang
YZYonglei Zhang
Yonglei Zhang
WZWenzhi Zhou
Wenzhi Zhou
The emergence of fast-switching wide-bandgap (GaN, SiC) power electronics devices has enabled motor drive systems to achieve high efficiency, power density, control bandwidth and high-level of integration. However, the fast-switching speed and high switching frequency result in an increased level of motor overvoltage at both motor terminals and stator neutral. This overvoltage increases the stress across the motor winding insulation and bearings. This paper investigates three types of motor overvoltages, i.e., differential mode (DM) (phase-to-phase) motor terminal overvoltage, common mode (CM) (phase-to-ground) motor terminal overvoltage and CM stator neutral overvoltage (motor neutral to ground). Both the high switching speed (high dv/dt) effect and the high switching frequency effect on the motor overvoltage are investigated in this paper, where the high switching frequency effect has not been fully addressed in existing literature. Significant overvoltage is observed when the switching frequency or its multiples coincide with the cable or motor anti-resonant frequency. The anti-resonant behavior in the cable and motor impedance has been used to identify the overvoltage oscillation frequency and to explain the overvoltage observations for the three types of motor overvoltages. The analysis has been tested using a 7.5kW motor setup with and without a four-core cable, driven by a SiC or a GaN three-phase inverter with a switching frequency up to 250kHz and switching speed up to 40kV/μ s. In addition, the motor bearing current, which is a main cause of bearing degradation, has also been tested and the increase of bearing current is observed due to the high frequency effect.

2 June 2020 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
WZWenzhi Zhou
Wenzhi Zhou
Xibo YuanXibo Yuan
Xibo Yuan
Silicon-carbide (SiC) MOSFETs have shown superior characteristics to Si IGBTs, bringing in significant performance improvement such as enabling more compact, higher efficiency converters that are not feasible with conventional Si IGBTs. Currently, there is a lack of systematic and conclusive investigation into soft-switching inverters using SiC MOSFETs in comparison to Si IGBTs. This article, therefore, presents a comparative evaluation of a soft-switching inverter, i.e., the auxiliary resonant commutated pole inverter (ARCPI) using SiC MOSFETs or Si IGBTs. The switching transition, switching device current stress, neutral point ripple current, electromagnetic interference (EMI), efficiency, and cost are compared on identical ARCPI setups, i.e., with the same printed circuit boards and under identical driving conditions (gate drivers). Experimental results show that the ARCPI using SiC MOSFETs has better performance than that using Si IGBTs due to its faster switching speed. First, the ARCPI using SiC MOSFETs performs full zero-voltage switching and the switching transition behavior is more predictable. Unlike Si IGBTs, SiC MOSFETs have no turn-off tail current and forward voltage drop during switching transitions. Second, the ARCPI using SiC MOSFETs endures less current stress and smaller ripple current in DC-link capacitors. Third, the ARCPI using SiC MOSFETs exhibits better EMI performance and higher efficiency. Specifically, a maximum 20 dBμV harmonic reduction can be achieved around 800 kHz and a 3.1% improvement in efficiency can be achieved at 6 kW.

8 March 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
WZWenzhi Zhou
Wenzhi Zhou
Mohamed DiabMohamed Diab
Mohamed Diab
Xibo YuanXibo Yuan
Xibo Yuan
CWChen Wei
Chen Wei
In silicon carbide (SiC) device based motor drives, the high-voltage slew-rate ( dv / dt ) associated with the fast-switching transitions results in excessive motor overvoltage, due to the reflected wave phenomenon, which increases the motor winding insulation stress and causes premature failure while raising electromagnetic interference (EMI) problems. This article proposes a soft-switching voltage slew-rate profiling approach to mitigate the motor overvoltage in SiC-based cable-fed drives. The proposed approach optimizes the rise/fall time of the output voltage according to the cable length, without altering the switching speed of the SiC devices. Since increasing the switching rise/fall time using conventional approaches, such as increasing the gate resistance, results in an increased switching power loss, the proposed profiling approach is implemented using a soft-switching inverter. The optimum rise/fall time that can significantly mitigate the overvoltage is derived using frequency- and time-domain analysis. The auxiliary resonant commutated pole inverter (ARCPI) is adopted as an example of the soft-switching inverter to experimentally verify the proposed slew-rate profiling approach for the overvoltage mitigation. The analysis and experimental results show that the motor overvoltage is fully mitigated when the output voltage rise/fall time is set as the cable antiresonance period, i.e., four times of the wave transmission time along the cable. Furthermore, the slew-rate profiling approach along with the ARCPI reduces the switching loss and improves the EMI performance at the high-frequency region, compared with the conventional hard-switching converter. Specifically, the maximum efficiency of the ARCPI is about 99%.

18 November 2021 in IEEE Access
Verified
Journal Article
Open access
Mohamed DiabMohamed Diab
Mohamed Diab
WZWenzhi Zhou
Wenzhi Zhou
CEChristopher Emersic
Christopher Emersic
Xibo YuanXibo Yuan
Xibo Yuan
ICIan Cotton
Ian Cotton
Partial discharge (PD) is a prime cause of premature failure of inverter-fed motor winding insulation. With the emergence of fast-switching wide-bandgap silicon-carbide (SiC) power semiconductor devices, random-wound motors are more vulnerable to highly repetitive PDs due to the high-frequency steep-fronted switching transitions that result in overvoltage oscillations at the motor terminals and non-uniform voltage distribution within the motor winding turns. This article investigates the impact of the applied PWM voltage waveforms on the PD behavior in SiC-based inverter-fed motors, including two-level, three-level, and quasi-three-level PWM waveforms. The electric field distribution inside insulation defects (air cavities) is analysed for the different PWM voltage waveforms to theoretically predict the number and phase of probable PD events within the fundamental cycle. An experimental PD measurement setup is used to validate the theoretical analysis by applying the PWM voltage waveforms, that are generated by SiC-based power converters, on a typical turn-to-turn motor winding insulation system created by a twisted pair of enamelled magnet wire. Phase-resolved PD patterns are generated to assess the PD behavior against the PWM characteristics of each voltage waveform and the associated overvoltage pattern when power cables are used to emulate the voltage reflections in cable-fed motor drives. Detailed experiment specifications are provided in this article involving PD measurement methods and PD data post-processing algorithms. The obtained results are assessed, and conclusions are drawn as a useful and timely reference that enhances the understanding of insulation PD process in SiC-based power electronics applications.

5 June 2023 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
WZWenzhi Zhou
Wenzhi Zhou
Mohamed DiabMohamed Diab
Mohamed Diab
Xibo YuanXibo Yuan
Xibo Yuan
LXLihong Xie
Lihong Xie
JWJun Wang
Jun Wang
ZZZhaobo Zhang
Zhaobo Zhang
This article proposes a quasi-three-level (Q3L) pulsewidth modulation (PWM)-based module-parallel inverter to address two major issues of deploying SiC mosfet s in high-power cable-fed adjustable speed drives. First, the maximum output power of SiC inverters is limited due to the lack of high current rating silicon carbide (SiC) devices, which cannot satisfy the demand of high-power applications, such as heavy-duty electric vehicles and more electric airplanes. The second issue comes from the fast-switching speed of SiC mosfet s, where power cables act like transmission lines under steep rising/falling voltages (high $dv/dt$ ), with back-and-forth voltage reflections that result in serious overvoltage oscillations at motor terminals. To address these issues, a SiC module-parallel inverter is adopted with elevated current capacity, where the phase voltage is maintained at the midpoint of a coupled inductor connected to the output nodes of each paralleled half-bridge module. By actively controlling the switching delay between the paralleled half-bridge legs, Q3L PWM waveforms are generated at the inverter output nodes that can mitigate the motor overvoltage due to the voltage reflections through power cables. An active current control technique is also proposed to facilitate the current balance between the paralleled half-bridge legs. The proposed Q3L PWM-based module-parallel inverter is experimentally verified using a SiC-based cable-fed motor drive system. The results show that the proposed approach can extend the current capabilities of SiC devices as well as mitigate motor overvoltage, enabling the adoption of SiC devices in high-power motor drives.

10 January 2022 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
WZWenzhi Zhou
Wenzhi Zhou
Mohamed DiabMohamed Diab
Mohamed Diab
Xibo YuanXibo Yuan
Xibo Yuan
In SiC-based adjustable speed drives, the high voltage slew rate ( $dv\!/\!dt$ ) of the switching transitions results in excessive overvoltage at the motor terminals due to the reflected voltages across the drive power cables. Besides the cable length, the switching rise/fall times of the voltage pulses are a key parameter to quantify the motor overvoltage in pulsewidth modulation (PWM) inverter-fed drives. These times are varying depending on the load current and parasitic elements of SiC mosfet s, that is, a standard two-level converter typically results in a nonuniform overvoltage envelop at the motor terminals. This article analyses the switching mechanism of the two-level converter considering the impact of SiC parasitic elements and load current showing how they affect the motor overvoltage in cable-fed drives. The analysis is then extended to the mitigation of the motor overvoltage using quasi-three-level (Q3L) modulation as a candidate filter-less approach with a T-type converter. The theoretical analysis is validated through experimental tests by using the Q3L T-type converter. The analysis and results show that the instantaneous load current value critically determines the peak motor overvoltage, while it allows either a full or partial overvoltage mitigation when the Q3L modulation is adopted.