24 February 2025 in IEEE Transactions on Instrumentation and Measurement
Aiming at the problems of low azimuth estimation accuracy and wide beam width of single vector hydrophone in low signal-to-noise ratio (SNR) environment, this paper proposes an azimuth estimation algorithm based on matched filter and adaptive noise residual accumulation of sound pressure vibration frequency deconvolution (MF-FDAC). This method uses the frequency domain output signal of each channel of the MEMS vector hydrophone after matched filtering, and finds that the two velocity components still show the sine and cosine weighting characteristics of the sound pressure propagation direction in the expression. By convoluting the frequency domain signal and using the residual energy difference between the output of the adaptive canceller on the target azimuth and the non-target azimuth, the target azimuth is estimated. The simulation results show that the root mean square error of the proposed algorithm is about 9° and the detection probability is 0.45 when the SNR is −10dB. The experimental results show that the maximum error of DOA estimation is 2° when the SNR is -7dB. In summary, compared with Conventional BeamForming(CBF), Multiple Signal Classification(MUSIC) and other algorithms, the proposed method has higher resolution, lower azimuth estimation error and more robust azimuth estimation ability under low SNR conditions.
13 June 2025 in Measurement
21 February 2025 in IEEE Transactions on Instrumentation and Measurement
With the development of underwater target noise reduction technologies, the detection capabilities of MEMS bionic vector hydrophones are encountering significant challenges in environments characterized by a low Signal-to-Noise Ratio (SNR). Thus, this paper proposes an innovative time-reversal convolution (TRC) processing method for both sound pressure and velocity based on the output characteristics of MEMS bionic vector hydrophones. This methodology capitalizes on the distinctions between signal and noise post-convolution processing, employing a subsequent stage of Adaptive Line Enhancement (ALE) technology to adeptly mitigate ambient interference, which in turn markedly augments the detection capabilities within low SNR. Additionally, addressing the challenge of broad main lobes in the directional pattern and the reduced precision in bearing estimation for single vector sensors during the processing of pressure and velocity signals, an innovative Direction of Arrival (DOA) estimation technique has been introduced. This technique employs adaptive cancellation of the outputs from TRC processing, enhancing the accuracy and reliability of the bearing estimation. Utilizing Monte Carlo simulations, this study meticulously examined the gain fluctuations in response to varying input SNRs and then meticulously contrasted with those of existing integrated methodologies to evaluate their comparative effectiveness. The simulation results demonstrate that the proposed methodology is capable of markedly amplifying the detection efficacy for low-intensity underwater targets within environments of diminished SNR. The potency of this approach in bolstering the operational prowess of MEMS bionic vector hydrophones is corroborated through empirical validation with actual test data.
30 March 2026 in Microsystems & Nanoengineering
To address the challenge of acoustic wave attenuation in traditional Micro-Electro-Mechanical Systems (MEMS) vector hydrophone packaging, this study proposes a sound-focusing package with tapered apertures (TA) and a nylon sound-focusing cap (NSC). Theoretical analysis and COMSOL simulations reveal that the tapered geometry (wider external and narrower internal apertures) concentrates acoustic energy, enhancing particle acceleration at sensitive elements. Experimental results show that the NSC achieves a sensitivity of −186.4 dB at 100 Hz, representing improvements of 7.9 dB and 6.1 dB compared with the steel mesh sound-transmitting cap (SMC) and non-encapsulated bare cilia (NC), respectively. The directivity null depth of the NSC-encapsulated hydrophone reaches 40.98 dB at 315 Hz, outperforming SMC and NC by 7.35 dB and 5.49 dB. The low Young’s modulus and density of nylon ensure a natural frequency in water (942.07 Hz) that exceeds the operating band (20–500 Hz), avoiding structural resonance and ensuring high signal-to-noise ratio output. The sound-focusing design, validated by standing wave tube tests, provides an effective solution for high-sensitivity and high-directivity underwater acoustic detection. Index Terms—MEMS vector hydrophone, sound-focusing package, tapered aperture, bionic cilia, sensitivity, directivity, low-frequency acoustic detection, nylon material.
6 February 2026 in IEEE Transactions on Instrumentation and Measurement
Cilium-based micro-electromechanical system (MEMS) vector hydrophones are critical in underwater acoustic detection, but their performance is highly sensitive to cilium geometry. Traditional trial-and-error methods are inefficient under complex constraints. This study presents an optimization approach using the constrained optimization by linear approximation (COBYLA) algorithm, combined with multiphysics finite element analysis, to improve sensitivity while precisely controlling the first-order characteristic frequency (FOCF). The cilium is parameterized with a seven-node interpolation curve, and an acoustic-structural coupled model is built in COMSOL. Under a 1000-Hz FOCF constraint, the maximum stress at the beam (MSB) is selected as the optimization objective. COBYLA enables automatic iterative shape optimization with real-time performance feedback. Simulation results show a frequency deviation of less than 0.17% and a 21.3 dB@1-kHz improvement in sensitivity. A prototype fabricated using MEMS and 3-D printing technologies was tested in a standing wave tube, yielding a measured linear bandwidth of the sensor of 1000 Hz and a sensitivity of −175.8 dB@1 kHz re 1 V/ $\mu $ Pa, matching simulation predictions. Meanwhile, the fabricated sensor demonstrated stable operation after withstanding a 100-g shock and a hydrostatic pressure of 7 MPa. This work demonstrates a high-efficiency, high-accuracy framework for MEMS hydrophone design, offering enhanced performance in complex underwater acoustic environments.
23 May 2026 in SSRN Electronic Journal
To address the challenges of blurred time–frequency features and severe background noise interference in underwater acoustic signals under low signal-to-noise ratio conditions, where traditional time–frequency analysis methods struggle to balance high resolution and noise robustness, this paper proposes a blind detection algorithm based on an adaptive Generalized S-Transform (guided by the Minimum Rényi Entropy criterion. The proposed method constructs an elastic Gaussian window model with dual modulation factors of scale and decay, which theoretically unifies the Short-Time Fourier Transform and the S-transform. By introducing third-order Rényi entropy as a sparsity measure and incorporating the Rayleigh resolution criterion to establish a physically constrained parameter space, a closed-loop parameter optimization mechanism is developed, enabling adaptive ”blind focusing” on unknown target features. Simulation results demonstrate that, under a signal duration of 5 s, the proposed method can effectively resolve steady-state components with a frequency spacing of 0.5 Hz, while achieving a spectral separation depth exceeding 15 dB in tracking dynamic linear frequency-modulated signals. Experimental results from Qiandao Lake further show that, under strong multipath interference and an SNR as low as 3.08 dB, the proposed method produces clearer and more continuous time–frequency ridges compared with STFT and FSST. It should be noted that frequency resolution is fundamentally constrained by the effective observation time and signal coherence. By adaptively optimizing the time–frequency window parameters, the proposed method enhances the concentration and resolution of time–frequency representations under given observation conditions, providing a robust and effective approach for weak target detection in complex underwater acoustic environments.