Renxin Wang

Renxin Wang


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
LCLixia Cheng
Lixia Cheng
RWRenxin Wang
Renxin Wang
XHXiaojian Hao
Xiaojian Hao
GLGuochang Liu
Guochang Liu
As a new material, graphene shows excellent properties in mechanics, electricity, optics, and so on, which makes it widely concerned by people. At present, it is difficult for graphene pressure sensor to meet both high sensitivity and large pressure detection range at the same time. Therefore, it is highly desirable to produce flexible pressure sensors with sufficient sensitivity in a wide working range and with simple process. Herein, a relatively high flexible pressure sensor based on piezoresistivity is presented by combining the conical microstructure polydimethylsiloxane (PDMS) with bilayer graphene together. The piezoresistive material (bilayer graphene) attached to the flexible substrate can convert the local deformation caused by the vertical force into the change of resistance. Results show that the pressure sensor based on conical microstructure PDMS-bilayer graphene can operate at a pressure range of 20 kPa while maintaining a sensitivity of 0.122 ± 0.002 kPa−1 (0–5 kPa) and 0.077 ± 0.002 kPa−1 (5–20 kPa), respectively. The response time of the sensor is about 70 ms. In addition to the high sensitivity of the pressure sensor, it also has excellent reproducibility at different pressure and temperature. The pressure sensor based on conical microstructure PDMS-bilayer graphene can sense the motion of joint well when the index finger is bent, which makes it possible to be applied in electronic skin, flexible electronic devices, and other fields.

12 January 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
LCLixia Cheng
Lixia Cheng
XHXiaojian Hao
Xiaojian Hao
GLGuochang Liu
Guochang Liu
WZWendong Zhang
Wendong Zhang
JCJiangong Cui
Jiangong Cui
RWRenxin Wang
Renxin Wang
With advances in new materials and technologies, there has been increasing research focused on flexible sensors. However, in most flexible pressure sensors made using new materials, it is challenging to achieve high detection sensitivity across a wide pressure range. Although traditional silicon-based sensors have good performance, they are not formable and, because of their rigidity and brittleness, they are not suitable for fitting with soft human skin, which limits their application in wearable devices to collect various signals. Silicon nanomembranes are ultra-thin, flexible materials with excellent piezoresistive properties, and they can be applied in various fields, such as in soft robots and flexible devices. In this study, we developed a flexible pressure sensor based on the use of silicon nanomembranes (with a thickness of only 340 nm) as piezoresistive units, which were transferred onto a flexible polydimethylsiloxane (PDMS) substrate. The flexible pressure sensor operated normally in the range of 0–200 kPa, and the sensitivity of the sensor reached 0.0185 kPa−1 in the low-pressure range of 0–5 kPa. In the high-pressure range of 5–200 kPa, the sensitivity of the sensor was maintained at 0.0023 kPa−1. The proposed sensor exhibited a fast response and excellent long-term stability and could recognize human movements, such as the bending of fingers and wrist joints, while maintaining a stable output. Thus, the developed flexible pressure sensor has promising applications in body monitoring and wearable devices.

29 February 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
GLGuochang Liu
Guochang Liu
HTHaoyu Tan
Haoyu Tan
HLHaoxuan Li
Haoxuan Li
JZJie Zhang
Jie Zhang
ZBZhengyu Bai
Zhengyu Bai
RWRenxin Wang
Renxin Wang
The miniaturization of low-frequency marine underwater acoustic detection systems presents new requirements for three-dimensional vector hydrophones. Inspired by fish lateral lines, we have introduced a biomimetic three-dimensional vector hydrophone. It features a microstructure with a monolithically integrated four-beam central block and cilium, capable of detecting underwater acoustic signals from three dimensions. Simulations were conducted to determine the natural frequencies and stress of the hydrophone, helping establish the structural parameters. The arrangement of piezoresistors on the four beams was meticulously designed to minimize inter-axis coupling. The hydrophone chip was fabricated using MEMS technology, followed by comprehensive testing. The hydrophone effectively operates within a detection frequency band of 20-500 Hz. The sensitivities for the three axes are -189 dB@500 Hz, -189.6 dB@500 Hz, and -200.9 dB@500 Hz (0 dB=1 V/μPa), respectively. The concave point depths are 30.4 dB, 29.8 dB, and 26.9 dB, with the voltage density of self-noise at -106 dB at 500 Hz. These results indicate that the biomimetic three-dimensional vector hydrophone holds promising prospects for low-frequency underwater acoustic detection applications.

9 October 2016 in Sensors
Verified
Journal Article
Open access
PDF file
RWRenxin Wang
Renxin Wang
WWWei Wang
Wei Wang
ZLZhihong Li
Zhihong Li
Silicon microneedle arrays (MNAs) have been widely studied due to their potential in various transdermal applications. However, discrete MNAs, as a preferred choice to fabricate flexible penetrating devices that could adapt curved and elastic tissue, are rarely reported. Furthermore, the reported discrete MNAs have disadvantages lying in uniformity and height-pitch ratio. Therefore, an improved technique is developed to manufacture discrete MNA with tunable height-pitch ratio, which involves KOH-dicing-KOH process. The detailed process is sketched and simulated to illustrate the formation of microneedles. Furthermore, the undercutting of convex mask in two KOH etching steps are mathematically analyzed, in order to reveal the relationship between etching depth and mask dimension. Subsequently, fabrication results demonstrate KOH-dicing-KOH process. {321} facet is figured out as the surface of octagonal pyramid microneedle. MNAs with diverse height and pitch are also presented to identify the versatility of this approach. At last, the metallization is realized via successive electroplating.

10 August 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
GZGuojun Zhang
Guojun Zhang
LZLansheng Zhang
Lansheng Zhang
SJSongxiang Ji
Songxiang Ji
XYXi Yang
Xi Yang
RWRenxin Wang
Renxin Wang
SYShie Yang
Shie Yang
The bionic cilium MEMS vector hydrophone has the characteristics of low power consumption, small volume, and good low-frequency response. Nevertheless, there exists the problem of left–right ambiguity in the azimuth estimation of a single hydrophone. In order to solve the engineering application problem, a sound-pressure sound-pressure-gradient hydrophone is designed in this paper. The new composite hydrophone consists of two channels. The bionic cilium microstructure is optimized and used as the vector channel, to collect the sound pressure gradient information, and a scalar channel, based on a piezoelectric ceramic tube, is added, to receive the sound pressure information. The theoretical analysis, simulation analysis, and test analysis of the composite hydrophone are carried out, respectively. The test results show that the sensitivities of the hydrophone can reach up to −188 dB (vector channel) and −204 dB (scalar channel). The problem of left–right ambiguity is solved by combining the sound pressure and sound pressure gradient in different ways. This is of great significance in the engineering application of single cilium MEMS hydrophone orientation.

26 October 2018 in Sensors
Verified
Journal Article
Open access
PDF file
JSJinlong Song
Jinlong Song
Changde HeChangde He
Changde He
RWRenxin Wang
Renxin Wang
CXChenyang Xue
Chenyang Xue
WZWendong Zhang
Wendong Zhang
A mathematical model of a sensor is vital to deeply comprehend its working principle and implement its optimal design. However, mathematical models of piezo-resistive eight-beam three-axis accelerometers have rarely been reported. Furthermore, those works are largely focused on the analysis of sensing acceleration in the normal direction, rather than in three directions. Therefore, a complete mathematical model of a piezo-resistive eight-beam three-axis accelerometer is developed in this paper. The validity of the mathematical model is proved by a Finite Element Method (FEM) simulation. Furthermore, the accelerometer is fabricated and tested. The prime sensitivities of X, Y and Z axes are 0.209 mV/g, 0.212 mV/g and 1.247 mV/g at 160 Hz, respectively, which is in accord with the values obtained by the model. The reason why the prime sensitivity SZZ is bigger than SXX and SYY is explained. Besides, it is also demonstrated why the cross-sensitivities SXZ and SYZ exceed SZX and SZY. Compared with the FEM model, the developed model could be helpful in evaluating the performance of three-axis accelerometers in an accurate and rapid way.