Reconfigurable modular robots, which can actively assemble and disassemble on command, offer the possibility of mesoscale (milliscale and microscale) manufacturing with robustness and controllability. In this study, we present a design of a scalable modular subunit with embedded permanent magnets in a 3-D printed cubic body. The subunit can be wirelessly controlled by an external uniform magnetic field. We also present controlled assembly–disassembly techniques for these subunits. Our modular robotic platform is highly reconfigurable and can create programmable, predetermined patterns based on open-loop control. The 2-D motion planner computes all reachable polyomino shapes from an arbitrary initial configuration and provides the shortest movement sequences to form each shape. Experimental results match computational modeling, demonstrating robust and reproducible behavior of the modular robotic platform that is promising for mesoscale manufacturing applications. Two cube sizes were tested: 10-mm edge lengths and 2.8-mm edge lengths.
17 July 2023 in IEEE Robotics and Automation Letters
Reconfigurable modular robots can dynamically assemble/disassemble to accomplish the desired task better. Magnetic modular cubes are scalable modular subunits with embedded permanent magnets in a 3D-printed cubic body and can be wirelessly controlled by an external, uniform, time-varying magnetic field. This letter considers the problem of self-assembling these modules into desired 2D polyomino shapes using such magnetic fields. Although the applied magnetic field is the same for each magnetic modular cube, we use collisions with workspace boundaries to rearrange the cubes. We present a closed-loop control method for self-assembling the magnetic modular cubes into polyomino shapes, using computer vision-based feedback with re-planning. Experimental results demonstrate that the proposed closed-loop control improves the success rate of forming 2D user-specified polyominoes compared to an open-loop baseline. We also demonstrate the validity of the approach over changes in length scales, testing with both 10 mm edge length cubes and 2.8 mm edge length cubes.
27 January 2022 in IEEE Robotics and Automation Letters
Micro/millimeter-scale magnetic robots have many potential biomedical applications. However, there are major challenges in using these devices for in vivo tasks due to limitations of imaging technology for real-time detection and navigation inside the human body. Ultrasound is a popular sensor for localizing such robots because it is easy to use and less expensive than other imaging methods. This letter studies methods to track and control a millimeter-scale rotating magnetic swimmer to perform path following. Detection using ultrasound B-mode and Doppler mode to track the robot during navigation are compared. In addition, an algorithm to perform 2.5D closed-loop control (controlling 3 degrees of freedom for a swimmer to follow a planar path) of the swimmer using only 2D ultrasound feedback was studied and tested experimentally.
This study investigates the efficacy of an untethered magnetic robot (UMR) for wireless mechanical and hybrid blood clot removal in ex vivo tissue environments. By integrating x-ray-guided wireless manipulation with UMRs, we aim to address challenges associated with precise and controlled blood clot intervention. The untethered nature and size of these robots enhance maneuverability and accessibility within complex vascular networks, potentially improving clot removal efficiency. We explore mechanical fragmentation, chemical lysis, and hybrid dissolution techniques that combine mechanical fragmentation with chemical lysis, highlighting their potential for targeted and efficient blood clot removal. Through experimental validation using an ex vivo endovascular thrombosis model within the iliac artery of a sheep, we demonstrate direct revascularization of a 13-mm-long, 1-day-old blood clot positioned inside the left common iliac artery. This was achieved by deploying a UMR into the abdominal aorta within 15 min. Additionally, both mechanical fragmentation and hybrid dissolution achieve a greater volume rate of change compared to no intervention (control) and chemical lysis alone. Mechanical fragmentation exhibits clot removal with a median of 0.87 mm3/min and a range of 2.81 mm3/min, while the hybrid approach demonstrates slower but more consistent clot removal, with a median of 0.45 mm3/min and a range of 0.23 mm3/min.
This paper examines a family of designs for magnetic cubes and counts how many configurations are possible for each design as a function of the number of modules. Magnetic modular cubes are cubes with magnets arranged on their faces. The magnets are positioned so that each face has either magnetic south or north pole outward. Moreover, we require that the net magnetic moment of the cube passes through the center of opposing faces. These magnetic arrangements enable coupling when cube faces with opposite polarity are brought in close proximity and enable moving the cubes by controlling the orientation of a global magnetic field. This paper investigates the 2D and 3D shapes that can be constructed by magnetic modular cubes, and describes all possible magnet arrangements that obey these rules. We select ten magnetic arrangements and assign a "color" to each of them for ease of visualization and reference. We provide a method to enumerate the number of unique polyominoes and polycubes that can be constructed from a given set of colored cubes. We use this method to enumerate all arrangements for up to 20 modules in 2D and 16 modules in 3D. We provide a motion planner for 2D assembly and through simulations compare which arrangements require fewer movements to generate and which arrangements are more common. Hardware demonstrations explore the self-assembly and disassembly of these modules in 2D and 3D.
25 March 2025 in IEEE Robotics and Automation Letters
Navigating through the peripheral lung branches poses a significant challenge in diagnosing lesions during bronchoscopy. Soft robots are well-suited to address current limitations in bronchoscopy due to their scale, dexterity, and adaptability. In this letter, we propose a real-time, semi-autonomous navigation platform that leverages a soft continuum robot with an outer diameter of 2.5 mm for tip steering and a UR5e robot arm for insertion, translation, and rotation. Closed-loop feedback is provided via on-board visualization and electromagnetic tracking. Steering capability and workspace are characterized to demonstrate sufficient robot tip dexterity. A driving algorithm combined with a YOLO-based computer vision algorithm is developed to enable the robot to steer toward the target branch along preplanned paths. Multiple successful navigational experiments were performed within an in-vitro lung phantom to validate the proposed platform. The scale of the robot allows for successful navigation deep into the smaller, peripheral branches of the lung (6th generation) and exits the lung phantom, demonstrating the ability to reach the lung periphery with an average error at the target location of 1.1 mm.