Online detection of rotor and load faults in permanent magnet synchronous motors (PMSM) based on spectrum analysis of current or vibration is not capable of identifying the root cause of the fault, since all faults produce identical fault signatures. The sensitivity of fault detection also depends on the motor and controller design making fault detection unreliable. In addition, operation under variable frequency and load limits the effectiveness of spectrum analysis based methods. In this article, airgap flux monitoring is investigated as an alternative for providing reliable identification of rotor and load faults in PMSMs. Based on the analysis of airgap flux under partial and uniform demagnetization, dynamic eccentricity, and load unbalance, an airgap search coil voltage based method for detection and classification of the faults is proposed. The claims made in the article are verified through experimental testing on an IPMSM under emulated fault conditions along with a comparison to vibration and current spectra-based detection. It is shown that the proposed method provides reliable online identification of the faults for cases where conventional spectrum analysis based methods fail.
22 February 2023 in IEEE Transactions on Industry Applications
Irreversible demagnetization of permanent magnets (PM) in PM synchronous motors (PMSM) degrades the performance and efficiency of the machine and drive system. Demagnetizing MMF applied to PMs operating at high temperature is known as one of the leading root causes of irreversible PM demagnetization. This is most likely to cause of demagnetization on the trailing edge of the PMs in all poles, as witnessed by prior research and industrial case studies presented in this work. However, most of the work on detecting PM demagnetization focus on uniform or partial (local) PM demagnetization. In this paper, a comparative evaluation of existing test methods on the detectability of trailing edge PM demagnetization, is given. It is shown that it is difficult to detect this type of fault with back-EMF, stator current/voltage, vibration, or leakage flux-based analysis, since trailing edge demagnetization does not produce asymmetry between PMs. An experimental study on a 380 V, 8 pole, 1.8 kW surface PMSM with trailing edge PM demagnetization shows that airgap flux-based detection is the most reliable means of detecting this fault.
17 March 2023 in IEEE Transactions on Industry Applications
Electrical stresses in industrial variable frequency drive (VFD) motors are increasing with the higher voltage and dv/dt levels, and with the advent of wide bandgap power devices. This increases the likelihood of partial discharge (PD) in VFD motors, and is expected to increase the risk of stator insulation failures in low voltage (LV) motors for which the insulation is not resistant to PD. To ensure that PD does not occur during operation, LV VFD motors are qualified for PD-free operation in the design or manufacturing stages. However, the PD inception voltage of qualified LV motors decreases with insulation aging exposing them to the risk of PD-induced insulation failure. In this paper, an automated off-line test method for VFD-embedded PD testing is proposed. The main idea is to perform PD testing whenever the motor is stopped at a voltage higher than the operating voltage to identify PD activity in the insulation before it occurs during operation. A series impulse and common mode voltage tests are proposed for stressing the different components of insulation for early identification of PD in terminal-/neutral-end ground, phase, and turn insulation. Testing on a LV, VFD motor verifies that PD can be identified whenever the motor is stopped to provide early warning of insulation failure.
10 April 2023 in IEEE Transactions on Energy Conversion
The pole drop test is the most widely applied means of detecting shorted turns in the rotor field winding of salient pole wound field synchronous machines (WFSM). It is a simple off-line test that relies on detecting the asymmetry between the voltage drop in the windings of each pole with ac voltage applied to the field winding terminals. Although it can provide sensitive detection of shorted field turns, it is also influenced by asymmetries in the motor produced by defects or imperfections in the rotor poles or damper bars. In this work, the feasibility of using the pole drop test for detecting damper bar and eccentricity faults in addition to shorted field windings is investigated for the first time. The change in the impedance of each pole under the fault conditions is analyzed from the electrical equivalent circuit and finite element (FE) simulation. Based on the analysis, it is shown that the 3 faults can be detected and classified from the impedance or voltage distribution with the pole drop test. Experimental tests performed on 4 pole, 30 kVA and 6 pole, 5.5 kVA salient pole WFSMs confirm that the 3 faults can be identified as claimed.
17 April 2023 in IEEE Transactions on Industry Applications
Magnet demagnetization in permanent magnet synchronous machines (PMSMs) can produce inadmissible performance degradation. Search coils (SCs) have been proven to be a viable option for its detection. Existing methods allow detection of demagnetization of one permanent magnet with three or less SCs. However, detection and severity assessment of the fault has been reported only for the particular case of using one SC per stator slot. This paper proposes two alternative methods for demagnetization detection and severity assessment of PMSMs using a reduced number of SCs. The first method relies on the zero-sequence voltage of three SCs electrically shifted 120 electrical degrees. The second method relies on the differential induced voltage between two SCs electrically shifted 360º. It will be shown that the proposed methods improve the performance of existing methods. Experimental results validating the proposed approach will be provided.
14 August 2024 in IEEE Transactions on Industry Applications
Failure in the rotor winding insulation of doublyfed induction generators (DFIG) is common due to the harsh environment and operating stresses. However, testing rotor insulation is difficult and costly due to the limited accessibility of wind generators as they are installed at remote locations inside the nacelle. Therefore, remote and automated insulation testing can help improve the reliability and reduce maintenance cost of wind generators. In this paper, a new approach for testing the integrity of rotor winding insulation for DFIGs is proposed. The main idea is to use the rotor-side inverter to perform off-line insulation testing whenever the wind generator is stopped. New test methods for off-line 1) partial discharge (PD) detection based on impulse voltage excitation and 2) capacitance (C) and dissipation factor (DF) testing based on common mode voltage excitation are proposed. Testing on a 6.3 kW wound rotor induction machine is given to verify the effectiveness of the proposed rotor insulation test method