Boao Jin

Boao Jin

Auto-generated profile, based on publicly available information

Boao Jin

Key Laboratory of Noise and Vibration Research, Institute of Acoustics, Chinese Academy of Sciences, Beijing 100190, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 April 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
XCXiwang Cui
Xiwang Cui
YGYan Gao
Yan Gao
YMYifan Ma
Yifan Ma
YLYuyou Liu
Yuyou Liu
BJBoao Jin
Boao Jin
Acoustic waves induced by leakage attenuate as they propagate in the piping system. Difficulties are generally encountered in leak localization in plastic pipes since these waves are heavily attenuated than in metallic pipes. This study presents a leak localization method based on the variable step normalized least mean square (VS-LMS) adaptive filter. In the method, the optimal weight vector of the filter is determined for time delay estimation (TDE) without requirement of the prior knowledge of statistical characteristics of leak and noise signals. It has a desirable feature of sharpening the main peak of TDE curve through adaptive iterative learning process, thus improving the accuracy of TDE for leak localization. By adjusting the update mode of iteration step, the convergence speed of the VS-LMS algorithm can be greatly improved. A simulation model of leak wave propagation is established and is subsequently analyzed for leak localization with respects to the TDE accuracy. Experimental work is further carried out on a plastic pipe to verify the effectiveness of the proposed method. The simulation sand experimental results demonstrate that the proposed method outperforms the original LMS and basic cross-correlation methods for the leak localization in a water-filled plastic pipe.

27 January 2020 in Sensors
Verified
Journal Article
Open access
PDF file
PSPingling Sun
Pingling Sun
YGYan Gao
Yan Gao
BJBoao Jin
Boao Jin
MBMichael Brennan
Michael Brennan
The detection and location of pipeline leakage can be deduced from the time difference between the arrival leak signals measured by sensors placed at the pipe access points on either side of a suspected leak. Progress has been made in this area to offer a potential improvement over the conventional cross-correlation method for time delay estimation. This paper is concerned with identifying suitable sensors that can be easily deployed to monitor the pipe vibration due to the propagation of leak noise along the pipeline. In response to this, based on the low-frequency propagation characteristics of leak noise in our previous study, polyvinylidene fluoride (PVDF) wire sensors are proposed as a potential solution to detect the pipeline leak signals. Experimental investigations were carried out at a leak detection pipe rig built in the Chinese Academy of Sciences. Their performances for leak detection were shown in comparison with hydrophones. It is suggested that with special considerations given to aspects pertaining to non-intrusive deployment and low cost, the PVDF wire sensors are of particular interest and may lead to a promising replacement for commercial leak noise transducers.

29 March 2020 in Sensors
Verified
Journal Article
Open access
PDF file
SYShuan Yan
Shuan Yan
HYHongyong Yuan
Hongyong Yuan
YGYan Gao
Yan Gao
BJBoao Jin
Boao Jin
JMJennifer M. Muggleton
Jennifer M. Muggleton
LDLizheng Deng
Lizheng Deng
This paper is concerned with imaging techniques for mapping and locating underground pipeline leakage. Ground surface vibrations induced by the propagating axisymmetric wave can be measured by an array of acoustic/vibration sensors, with the extraction of magnitude information used to determine the position of leak source. A method of connected graph traversal is incorporated into the vibroacoustic technique to obtain the spatial image with better accuracy compared to the conventional magnitude contour plot. Measurements are made on a dedicated cast iron water pipe by an array of seven triaxial geophones. The spectral characteristics of the propagation of leak noise signals from underground water pipes to the ground surface are reported. Furthermore, it is demonstrated that suspicious leakage areas can be readily identified by extracting and fusing the feature patterns at low frequencies where leak noise dominates. The results agree well with the real leakage position in the underground pipeline.

12 June 2023 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
QLQinhao Lin
Qinhao Lin
DGDa Gao
Da Gao
BJBoao Jin
Boao Jin
YWYuqi Wang
Yuqi Wang
YYYonggang Yin
Yonggang Yin
JSJunhui Shi
Junhui Shi
Photoacoustic spectroscopy (PAS) has been proven to have great potential in health monitoring applications, such as continuous blood glucose or oxygen monitoring. However, due to the significant mismatch between different acoustic media, 99.9% of acoustic energy cannot propagate across the gas–liquid interface, which greatly limits the liquid detection sensitivity of PAS. In this study, a Helmholtz-type acoustic metasurface (HAM) consisting of a perforated plate and a subwavelength cavity filled with air is proposed to enhance the acoustic transmission across the gas–liquid interface. The behavior of the air layer within the HAM is analogous to the transverse vibration of a membrane, which would drive the vibration of the water surface and provide an effective path for sound transmission from water to air. Experimental results confirmed that HAM can increase the power transmission coefficient of sound from water to air by two orders of magnitude while maintaining optical transparency for laser. Furthermore, the performance of the PAS system coupled with HAM is investigated. It is demonstrated that the liquid detection sensitivity of PAS systems can be enhanced remarkably, with a 409% magnification of the signal intensity. The working frequency of HAM can also be flexibly adjusted from 0.01 to 20 kHz through parameter configuration, enabling compatibility with the operating frequency of PAS systems. It is expected to be applied in the field of liquid ingredient analysis and health monitoring.

29 January 2025 in Applied Acoustics
Verified
Journal Article
Closed access
JXJian Xu
Jian Xu
BJBoao Jin
Boao Jin
JZJin Zhang
Jin Zhang

31 December 2022 in Journal of Theoretical and Computational Acoustics
Verified
Journal Article
Open access
BJBoao Jin
Boao Jin
YGYan Gao
Yan Gao
ZJZhongkun Jin
Zhongkun Jin
The time-harmonic asymptotic solutions due to the surface horizontal vibration sources provide the theoretical basis in the applications of buried object detection. In the integral transformation method, the Rayleigh secular function appears in the denominator of the integrand of the inverse transformation. This leads to the multi-leaf characteristics of the integrand and the asymptotic solution is affected by the Rayleigh poles, resulting in a mismatch between the asymptotic time-harmonic solution and the finite element results. In this paper, an integral expression for the time-harmonic solution of the surface horizontal vibration source is derived using the integral transformation method. The asymptotic results using the steepest descent method are decomposed into the analytical component, the modified component of the poles and the residual component of the poles. Expressions for each component are given, with particular emphasis on the effect of the Rayleigh secular function on the asymptotic solution. It is found that for the multi-leaf problem, the asymptotic expressions related to shear waves should use the results of the γ++ leaf, while the asymptotic expressions related to compressional waves should use the results of the γ+− leaf when ????>arcsinh/k . Comparison of the numerical and semi-analytical solutions is made to verify the expressions for the analytical components, along with the selection of the Riemann surface.