Ian B. Flader

Ian B. Flader

Auto-generated profile, based on publicly available information

Ian B. Flader

Apple Inc., Cupertino, CA, USA

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2016
Verified
Conference Paper
Closed access
PTParsa Taheri-Tehrani
Parsa Taheri-Tehrani
MKMitchell Kline
Mitchell Kline
IIIgor Izyumin
Igor Izyumin
BEBurak Eminoglu
Burak Eminoglu
YYYu-Ching Yeh
Yu-Ching Yeh
DHDavid A. Horsley
David A. Horsley
We present an epitaxially-encapsulated 2×2 mm 2 quad-mass gyroscope (QMG). Relative to the earlier QMG which measured 8×8 mm 2 and required an external vacuum package and getter [1], this device is 16x smaller in area and is vacuum-sealed at the wafer-level. Due to the device's small size, high quality factor (Q) and large oscillation amplitude are required to achieve low noise. However, the device's high Q (85,000) makes it highly sensitive to mechanical nonlinearity, resulting in amplitude-frequency dependence and instability of the oscillator loop at large amplitudes. To overcome these problems, we demonstrate electrostatic compensation of the mechanical nonlinearity, enabling 10x greater amplitude and therefore scale factor (SF). Together with closed-loop amplitude control and quadrature compensation, this enables angle-random walk of 0.42 mdeg/s/VHz, comparable to the best QMG published to date. Closed-loop amplitude control and quadrature null are used to achieve a bias instability of 1.6 deg/hr.

1 January 2016
Verified
Conference Paper
Closed access
DGDustin D. Gerrard
Dustin D. Gerrard
CAChae H. Ahn
Chae H. Ahn
IFIan B. Flader
Ian B. Flader
YCYunhan Chen
Yunhan Chen
ENEldwin J. Ng
Eldwin J. Ng
TKThomas W. Kenny
Thomas W. Kenny
We present an assortment of geometrically parameterized disk resonator gyroscopes (DRGs) individually designed for resonant frequency (f) and quality factor (Q). This work demonstrates accurate FEM-based predictions of Q for fabricated devices, and geometric optimizations that significantly improve this key performance metric for the DRG. Measurements on suites of fabricated devices confirm that losses are dominated by thermoelastic dissipation (TED). Qted is shown to account for 64-80% of the total energy dissipation. The temperature dependence of Q is also used to confirm and quantify the presence of pressure damping in the fabricated devices. At frequencies near 300 kHz, we show that Q can be increased by a factor of 2.6 and demonstrate feasibility of geometric/topological optimization of the fabricated devices with the aid of finite element software.

1 January 2017
Verified
Conference Paper
Closed access
DGDustin D. Gerrard
Dustin D. Gerrard
JRJanna Rodriguez
Janna Rodriguez
LOLizmarie Comenencia Ortiz
Lizmarie Comenencia Ortiz
SCSaurabh A. Chandorkar
Saurabh A. Chandorkar
IFIan B. Flader
Ian B. Flader
TKThomas W. Kenny
Thomas W. Kenny
We demonstrate how to identify regions of major thermo-elastic dissipation (TED) in MEMS resonators and reduce this energy loss by modifying the device geometry. To demonstrate this, various geometries of a disk resonating gyroscope (DRG) are used. Devices are fabricated and tested to show that the TED-limited quality factor (Q) can indeed be increased using geometric manipulation, as predicted by simulation.

15 July 2020 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
AAAnne L. Alter
Anne L. Alter
IFIan B. Flader
Ian B. Flader
YCYunhan Chen
Yunhan Chen
DSDongsuk D. Shin
Dongsuk D. Shin
TKThomas W. Kenny
Thomas W. Kenny
In this paper, we observe amplitude-dependent nonlinear dissipation in experimental measurements of the quality factor (Q). The ringdown response is used to quantify the magnitude of the amplitude-dependent effect in both polysilicon and single crystal silicon (SCS). The Q is reduced in both materials, up to 15.6%, and has a stronger influence on the measurements of Q in polysilicon than in SCS. Since the measured limiting dissipation mechanism in these resonators is thermoelastic dissipation (TED), we suggest these results align with models of amplitude-dependent TED. [2020-0160]

12 March 2019 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
IFIan B. Flader
Ian B. Flader
KGKenneth E. Goodson
Kenneth E. Goodson
TKThomas Kenny
Thomas Kenny
YCYunhan Chen
Yunhan Chen
YYYushi Yang
Yushi Yang
WPWoosung Park
Woosung Park

16 September 2020 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
AAAnne L. Alter
Anne L. Alter
IFIan B. Flader
Ian B. Flader
YCYunhan Chen
Yunhan Chen
LOLizmarie Comenencia Ortiz
Lizmarie Comenencia Ortiz
DSDongsuk D. Shin
Dongsuk D. Shin
TKThomas W. Kenny
Thomas W. Kenny
Fatigue in thick (> 20 μm), epitaxially deposited polysilicon MEMS is characterized from 25°C and up to 250°C in an environment free of oxygen and humidity. This work is the first to report fatigue initiated in the native epi-polysilicon, free from any contributions due to oxide or environmental conditions. Fatigue was most prominent above stresses of 1.5 GPa at all temperatures. Resonant frequency shift is used to measure crack growth, and elevated temperatures increased the total frequency drift and frequency drift rates. Since the epi-polysilicon surfaces roughen due to grain boundary migration during fabrication, we conclude that epi-polysilicon fatigue can be attributed to a subcritical cracking mechanism that arises from surface roughness. Furthermore, the measured increases in the critical crack length before failure suggest that the fracture toughness increases at the elevated temperatures.