Yushi Yang

Yushi Yang

Auto-generated profile, based on publicly available information

Yushi Yang

Stanford University, Stanford, USA

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 July 2016 in Journal of Microelectromechanical Systems
Verified
Journal Article
Open access
YYYushi Yang
Yushi Yang
ENEldwin J. Ng
Eldwin J. Ng
PPPavel M. Polunin
Pavel M. Polunin
YCYunhan Chen
Yunhan Chen
IFIan B. Flader
Ian B. Flader
TKThomas W. Kenny
Thomas W. Kenny
We present an experimental study of conservative nonlinearities in bulk acoustic mode (bulk-mode) silicon MEMS resonators with degenerate doping. Three types of bulk acoustic mode resonators oriented in (110) and (100) silicon crystalline directions are used to analyze both linear and nonlinear elastic behavior of silicon with p- (N ≅ 4.19e + 18 to 1.63e + 20 cm -3 ) and n-type (N ≅ 1.58e + 18 to 5.91e + 19 cm -3 ) doping. For accurate characterization of the amplitude-dependent nonlinear stiffness constant, we employ two methods: amplitude-frequency response and ringdown measurement. Experimental results show that the nonlinear behavior of these resonators is dominated by material-dependent mechanical nonlinearities and strongly depends on the doping type and crystal orientation. These results are useful for understanding the material-induced nonlinear properties of doped silicon and design of MEMS resonators with desired dynamic behavior, and may provide a new avenue for tailoring resonator response characteristics.

15 September 2014 in Journal of Microelectromechanical Systems
Verified
Journal Article
Open access
CRClifton L. Roozeboom
Clifton L. Roozeboom
BHBridget E. Hill
Bridget E. Hill
VHVu Anh Hong
Vu Anh Hong
CAChae Hyuck Ahn
Chae Hyuck Ahn
ENEldwin J. Ng
Eldwin J. Ng
BPBeth L. Pruitt
Beth L. Pruitt
We present multifunctional integrated sensors (MFISES) that combine temperature, humidity, pressure, air speed, chemical gas, magnetic, and acceleration sensing on a single 2-mm × 2-mm die. We fabricate the MFISES in a wafer scale encapsulation process to hermetically seal the sensor functions with moving parts at low vacuum, and then surface micromachine the environmental sensors on top of the sealed layer. The encapsulation process provides very stable conditions for the pressure, magnetic, and acceleration sensors, and enables the deployment of the MFISES in dynamic environmental conditions without special postprocess packaging. We quantify the performance requirements for sensor applications in weather stations, indoor climate control, road activity monitoring, chemical sensing, and parking monitoring. We compare the performance of the MFISES to the application requirements to demonstrate the utility of an integrated sensor in a wide range of applications.

1 January 2016
Verified
Conference Paper
Closed access
DGDustin D. Gerrard
Dustin D. Gerrard
CAChae H. Ahn
Chae H. Ahn
IFIan B. Flader
Ian B. Flader
YCYunhan Chen
Yunhan Chen
ENEldwin J. Ng
Eldwin J. Ng
TKThomas W. Kenny
Thomas W. Kenny
We present an assortment of geometrically parameterized disk resonator gyroscopes (DRGs) individually designed for resonant frequency (f) and quality factor (Q). This work demonstrates accurate FEM-based predictions of Q for fabricated devices, and geometric optimizations that significantly improve this key performance metric for the DRG. Measurements on suites of fabricated devices confirm that losses are dominated by thermoelastic dissipation (TED). Qted is shown to account for 64-80% of the total energy dissipation. The temperature dependence of Q is also used to confirm and quantify the presence of pressure damping in the fabricated devices. At frequencies near 300 kHz, we show that Q can be increased by a factor of 2.6 and demonstrate feasibility of geometric/topological optimization of the fabricated devices with the aid of finite element software.

1 January 2016
Verified
Conference Paper
Closed access
PTParsa Taheri-Tehrani
Parsa Taheri-Tehrani
MKMitchell Kline
Mitchell Kline
IIIgor Izyumin
Igor Izyumin
BEBurak Eminoglu
Burak Eminoglu
YYYu-Ching Yeh
Yu-Ching Yeh
DHDavid A. Horsley
David A. Horsley
We present an epitaxially-encapsulated 2×2 mm 2 quad-mass gyroscope (QMG). Relative to the earlier QMG which measured 8×8 mm 2 and required an external vacuum package and getter [1], this device is 16x smaller in area and is vacuum-sealed at the wafer-level. Due to the device's small size, high quality factor (Q) and large oscillation amplitude are required to achieve low noise. However, the device's high Q (85,000) makes it highly sensitive to mechanical nonlinearity, resulting in amplitude-frequency dependence and instability of the oscillator loop at large amplitudes. To overcome these problems, we demonstrate electrostatic compensation of the mechanical nonlinearity, enabling 10x greater amplitude and therefore scale factor (SF). Together with closed-loop amplitude control and quadrature compensation, this enables angle-random walk of 0.42 mdeg/s/VHz, comparable to the best QMG published to date. Closed-loop amplitude control and quadrature null are used to achieve a bias instability of 1.6 deg/hr.

1 June 2013
Verified
Conference Paper
Closed access
CAC. H. Ahn
C. H. Ahn
ENE. J. Ng
E. J. Ng
VHV. A. Hong
V. A. Hong
YYY. Yang
Y. Yang
BLBrian Jun Lee
Brian Jun Lee
TKT. W. Kenny
T. W. Kenny
In this paper, we show two methods for modifying the design of a Disk Resonating Gyroscope (DRG) to compensate for the mechanical anisotropy in single crystal silicon. This method is validated through experimental characterization of more than 70 different devices. With the proposed methods, the frequency split of the 250kHz DRG “wineglass” modes in single crystal silicon was reduced from >10kHz to as los as 96Hz without any electrostatic tuning. These results allow development of high-performance miniature DRGs tuned for degenerate-mode operation from high-quality crystalline silicon material.

1 January 2014
Verified
Conference Paper
Closed access
SNS. Nitzan
S. Nitzan
TST-H. Su
T-H. Su
EAEthan C. Ahn
Ethan C. Ahn
ENE. Ng
E. Ng
VHV. Hong
V. Hong
DHD. A. Horsley
D. A. Horsley
This paper investigates the impact of operating a vibratory rate gyro (VRG) at large oscillation amplitude where the VRG's driven axis behaves like a nonlinear oscillator, described by the Duffing equation. Although open-loop resonators operating above a critical amplitude exhibit catastrophic jump instabilities, we demonstrate that through closed-loop operation, the drive axis can be stably operated at an amplitude above this threshold without impacting drive-axis stability or bias instability, resulting in decreased Angle Random Walk (ARW).