27 May 2019 in Journal of Endovascular Therapy
Purpose:To assess the feasibility of magnetic particle imaging (MPI) to guide stenting in a phantom model. Materials and Methods: MPI is a new tomographic imaging method based on the background-free magnetic field detection of a tracer agent composed of superparamagnetic iron oxide nanoparticles (SPIOs). All experiments were conducted on a custom-built MPI scanner (field of view: 29-mm diameter, 65-mm length; isotropic spatial resolution 1–1.5-mm). Stenosis phantoms (n=3) consisted of polyvinyl chloride (PVC) tubes (8-mm inner diameter) prepared with centrally aligned cable binders to form a ~50% stenosis. A dedicated image reconstruction algorithm allowed precise tracking of endovascular instruments at 8 frames/s with a latency time of ~115 ms. A custom-made MPI-visible lacquer was used to manually label conventional guidewires, balloon catheters, and stainless steel balloon-expandable stents. Vascular stenoses were visualized by injecting a diluted SPIO tracer (ferucarbotran, 10 mmol iron/L) into the vessel phantoms. Balloon angioplasty and stent placement were performed by inflating balloon catheters and stent delivery balloons with diluted ferucarbotran. Results: After deployment of the stent, the markers on its ends were clearly visible. The applied lacquer markers were thin enough to not relevantly alter gliding properties of the devices while withstanding friction during the experiments. Placing an optimized flexible lacquer formulation on the preexisting radiopaque stent markers provided enough stability to withstand stent expansion. Final MPA confirmed successful stenosis treatment, facilitated by the disappearance of the lacquer markers on the stent due to differences in SPIO concentration. Thus, the in-stent lumen could be visualized without interference by the signal from the markers. Conclusion: Near real-time visualization of MPI-guided stenting of stenoses in a phantom model is feasible. Optimized MPI-visible markers can withstand the expansion process of stents.
2 September 2019 in Scientific Reports
Magnetic Particle Imaging (MPI) is a promising new tomographic modality for fast as well as three-dimensional visualization of magnetic material. For anatomical or structural information an additional imaging modality such as computed tomography (CT) is required. In this paper, the first hybrid MPI-CT scanner for multimodal imaging providing simultaneous data acquisition is presented.
16 April 2018 in CardioVascular and Interventional Radiology
21 June 2017 in IEEE Transactions on Medical Imaging
Magnetic particle imaging (MPI) is a promising new tomographic imaging method to detect the spatial distribution of superparamagnetic iron-oxide nanoparticles (SPIOs). The aim of this paper was to investigate the potential of MPI to quantify artificial stenoses in vessel phantoms. Custom-made stenosis phantoms (length 40 mm; inner diameter 8 mm) with different degrees of stenosis (0%, 25%, 50%, 75%, and 100%) were scanned in a custom-built MPI scanner (in-plane resolution: ~1-1.5 mm and field of view: 65 × 29 × 29 mm 3 ). Phantoms were filled with diluted Feru-carbotran [SPIO agent, 5 mmol (Fe)/l]. Each measurement (overall acquisition time: 20 ms per image, 400 averages) was repeated ten times to assess reproducibility. The MPI signal was used for semi-automatic stenosis quantification. Two stenosis evaluation approaches were compared based on the signal intensity profile alongside the stenosis phantoms. Using a novel multi-step image evaluation approach, MPI allowed for accurate quantification of different stenosis grades. While low grade stenoses were slightly over-estimated, high grade stenoses were slightly underestimated. In particular, the 0%, 25%, and 50% stenosis phantoms revealed a 6.2% ± 0.8, 25.7% ± 1.0, and 48.0% ± 1.5 stenosis, respectively. The higher grade 75% stenosis phantom revealed a 73.3% ± 2.8 and the 100% stenosis phantom a 95.8% ± 1.9 stenosis. MPI accurately visualized and quantified different stenosis grades in vessel phantoms with high reproducibility demonstrating its great potential for fast and radiation-free preclinical cardiovascular imaging.
10 January 2020 in IEEE Transactions on Medical Imaging
Magnetic Particle Imaging (MPI) is a fast imaging technique to visualize the distribution of superparamagnetic iron-oxide nanoparticles (SPIONs). For spatial encoding, a field free area is moved rapidly through the field of view (FOV) generating localized signal. Fast moving samples, e.g., a bolus of SPIONs traveling through the large veins in the human body carried by blood flow with velocities in the order of ~45 cm/s, cause temporal blurring in MPI measurements using common sequences and reconstruction techniques. This hampers the evaluation of dynamics of fast moving samples. In this manuscript, a first study on fast moving samples visualized within an MPI scanner is demonstrated. By optimizing parameters for imaging and reconstruction, the dynamics of a fast moving bolus at different velocities can be visualized with high temporal resolution without blurring artifacts.
2 July 2019 in IEEE Transactions on Magnetics
Magnetic particle imaging (MPI) is a novel tomographic imaging method, which allows determining the distribution of superparamagnetic iron-oxide nanoparticles in three dimensions. So far, various MPI systems have been presented with each one emphasizing different scanner features such as large field of view (FOV) or high resolution. For imaging with both high resolution and a large FOV, the optimization and harmonization of hardware parameters as well as tracer material are key prerequisites. The traveling wave MPI (TWMPI) approach uses an array of electromagnets, which can provide a high magnetic field gradient for a high resolution as well as a mouse-sized FOV at the same time. In combination with the tracer LS-008, which is optimized for the MPI technique, a resolution in the sub-millimeter range can be achieved. In this paper, an optimized scanner is presented based on the TWMPI approach featuring a gradient strength up to almost 10 T/m in an FOV with a length of 45 mm providing a high resolution below 500 microns using the optimized LS-008 tracer.