High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS) is a versatile technique for the detection of gaseous target molecules that is particularly useful in complex chemical environments, while the instrumental effort is low. Operating HiKE-IMS at reduced pressures from 10 to 60 mbar results in fewer ion-neutral collisions than at ambient pressure, reducing chemical cross-sensitivities and eliminating the need for a preceding separation dimension, e.g., by gas chromatography. In addition, HiKE-IMS allows operation over a wide range of reduced electric field strengths E/N up to 120 Td, allowing separation of ions by low-field ion mobility and exploiting the field dependence of ion mobility, potentially allowing separation of ion species at high E/N despite similar low-field ion mobilities. Given these advantages, HiKE-IMS can be a useful tool for trace gas analysis such as triacetone triperoxide (TATP) detection. In this study, we employed HiKE-IMS to detect TATP. We explore the ionization of TATP and the field-dependent ion mobilities, providing a database of the ion mobilities depending on E/N. Confirming the literature results, ionization of TATP by proton transfer with H3O+ in HiKE-IMS generates fragments, but using NH4+ as the primary reactant ion leads to the TATP·NH4+ adduct. This adduct fragments at high E/N, which could provide additional information for reliable detection of TATP. Thus, operating HiKE-IMS at variable E/N in the drift region generates a unique fingerprint of TATP made of all ion species related to TATP and their ion mobilities depending on E/N, potentially reducing the rate of false positives.
16 July 2024 in Journal of the American Society for Mass Spectrometry
High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) ionize and separate ions at reduced pressures of 10-40 mbar and over a wide range of reduced electric field strengths E/N of up to 120 Td. Their reduced operating pressure is distinct from that of conventional drift tube ion mobility spectrometers that operate at ambient pressure for trace compound detection. High E/N can lead to a field-induced fragmentation pattern that provides more specific structural information about the analytes. In addition, operation at high E/N values adds the field dependence of ion mobility as an additional separation dimension to low-field ion mobility, making interfering compounds less likely to cause a false positive alarm. In this work, we study the chemical warfare agents tabun (GA), sarin (GB), soman (GD), cyclosarin (GF) and sulfur mustard (HD) in a HiKE-IMS at variable E/N in both the reaction and the drift region. The results show that varying E/N can lead to specific fragmentation patterns at high E/N values combined with molecular signals at low E/N. Compared to the operation at a single E/N value in the drift region, the variation of E/N in the drift region also provides the analyte-specific field dependence of ion mobility as additional information. The accumulated data establish a unique fingerprint for each analyte that allows for reliable detection of chemical warfare agents even in the presence of interfering compounds with similar low-field ion mobilities, thus reducing false positives.
2 September 2020 in Journal of the American Society for Mass Spectrometry