1 June 2015 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Verified
Journal Article
Open access
KMKevin L. Moore
Kevin L. Moore
RSRachel Schmidt
Rachel Schmidt
VMVitali Moiseenko
Vitali Moiseenko
LOLindsey A. Olsen
Lindsey A. Olsen
JTJun Tan
Jun Tan
SMSasa Mutic
Sasa Mutic
The purpose of this study was to quantify the frequency and clinical severity of quality deficiencies in intensity modulated radiation therapy (IMRT) planning in the Radiation Therapy Oncology Group 0126 protocol. A total of 219 IMRT patients from the high-dose arm (79.2 Gy) of RTOG 0126 were analyzed. To quantify plan quality, we used established knowledge-based methods for patient-specific dose-volume histogram (DVH) prediction of organs at risk and a Lyman-Kutcher-Burman (LKB) model for grade ≥2 rectal complications to convert DVHs into normal tissue complication probabilities (NTCPs). The LKB model was validated by fitting dose-response parameters relative to observed toxicities. The 90th percentile (22 of 219) of plans with the lowest excess risk (difference between clinical and model-predicted NTCP) were used to create a model for the presumed best practices in the protocol (pDVH0126,top10%). Applying the resultant model to the entire sample enabled comparisons between DVHs that patients could have received to DVHs they actually received. Excess risk quantified the clinical impact of suboptimal planning. Accuracy of pDVH predictions was validated by replanning 30 of 219 patients (13.7%), including equal numbers of presumed "high-quality," "low-quality," and randomly sampled plans. NTCP-predicted toxicities were compared to adverse events on protocol. Existing models showed that bladder-sparing variations were less prevalent than rectum quality variations and that increased rectal sparing was not correlated with target metrics (dose received by 98% and 2% of the PTV, respectively). Observed toxicities were consistent with current LKB parameters. Converting DVH and pDVH0126,top10% to rectal NTCPs, we observed 94 of 219 patients (42.9%) with ≥5% excess risk, 20 of 219 patients (9.1%) with ≥10% excess risk, and 2 of 219 patients (0.9%) with ≥15% excess risk. Replanning demonstrated the predicted NTCP reductions while maintaining the volume of the PTV receiving prescription dose. An equivalent sample of high-quality plans showed fewer toxicities than low-quality plans, 6 of 73 versus 10 of 73 respectively, although these differences were not significant (P=.21) due to insufficient statistical power in this retrospective study. Plan quality deficiencies in RTOG 0126 exposed patients to substantial excess risk for rectal complications.

10 April 2023 in Physics and Imaging in Radiation Oncology
Verified
Journal Article
Open access
TZTingliang Zhuang
Tingliang Zhuang
GGGrant Gibbard
Grant Gibbard
XDXinhui Duan
Xinhui Duan
JTJun Tan
Jun Tan
YPYang Park
Yang Park
BCBin Cai
Bin Cai
A recently developed biology-guided radiotherapy platform, equipped with positron emission tomography (PET) and computed tomography (CT), provides both anatomical and functional image guidance for radiotherapy. This study aimed to characterize performance of the kilovoltage CT (kVCT) system on this platform using standard quality metrics measured on phantom and patient images, using CT simulator images as reference. Image quality metrics, including spatial resolution/modular transfer function (MTF), slice sensitivity profile (SSP), noise performance and image uniformity, contrast-noise ratio (CNR) and low-contrast resolution, geometric accuracy, and CT number (HU) accuracy, were evaluated on phantom images. Patient images were evaluated mainly qualitatively. On phantom images the MTF10% is about 0.68 lp/mm for kVCT in PET/CT Linac. The SSP agreed with nominal slice thickness within 0.7 mm. The diameter of the smallest visible target (1% contrast) is about 5 mm using medium dose mode. The image uniformity is within 2.0 HU. The geometric accuracy tests passed within 0.5 mm. Relative to CT simulator images, the noise is generally higher and the CNR is lower in PET/CT Linac kVCT images. The CT number accuracy is comparable between the two systems with maximum deviation from the phantom manufacturer range within 25 HU. On patient images, higher spatial resolution and image noise are observed on PET/CT Linac kVCT images. Major image quality metrics of the PET/CT Linac kVCT were within vendor-recommended tolerances. Better spatial resolution but higher noise and better/comparable low contrast visibility were observed as compared to a CT simulator when images were acquired with clinical protocols.

8 December 2022 in Biomedical Physics & Engineering Express
Verified
Journal Article
Open access
PDF file
ZXZhenyu Xiong
Zhenyu Xiong
YZYuncheng Zhong
Yuncheng Zhong
TBThomas I. Banks
Thomas I. Banks
RRRobert Reynolds
Robert Reynolds
TCTsuicheng Chiu
Tsuicheng Chiu
SSStrahinja Stojadinovic
Strahinja Stojadinovic
Objectives. The purpose of this study is to present data from the clinical commissioning of an Xstrahl 150 x-ray unit used for superficial radiotherapy, Methods. Commissioning tasks included vendor acceptance tests, timer reproducibility, linearity and end-effect measurements, half-value layer (HVL) measurements, inverse square law verification, head-leakage measurements, and beam output calibration. In addition, percent depth dose (PDD) curves were determined for different combinations of filter/kV settings and applicators. Automated PDD water phantom scans were performed utilizing four contemporary detectors: a microDiamond detector, a microSilicon detector, an EDGE detector, and a PinPoint ionization chamber. The measured PDD data were compared to the published values in BJR Supplement 25, Results. The x-ray unit’s mechanical, safety, and radiation characteristics were within vendor-stated specifications. Across sixty commissioned x-ray beams, the PDDs determined in water using solid state detectors were in excellent agreement with the BJR 25 data. For the lower (<100 kVp) and medium-energy (≥100 kVp) superficial beams the average agreement was within [−3.6,+0.4]% and [−3.7,+1.4]% range, respectively. For the high-energy superficial (low-energy orthovoltage) x-rays at 150 kVp, the average difference for the largest 20 × 20 cm2 collimator was (−0.7 ± 1.0)%, Conclusions. This study presents machine characterization data collected for clinical use of a superficial x-ray unit. Special focus was placed on utilizing contemporary detectors and techniques for the relative PDD measurements using a motorized water phantom. The results in this study confirm that the aggregate values published in the BJR 25 report still serve as a valid benchmark when comparing data from site-specific measurements, or the reference data for clinical utilization without such measurements, Advances in knowledge. This paper presents comprehensive data from the acceptance and commissioning of a modern kilovoltage superficial x-ray radiotherapy machine. Comparisons between the PDD data measured in this study using different detectors and BJR 25 data are highlighted.

1 August 2025 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
JTJun Tan
Jun Tan
APAlessio Parisi
Alessio Parisi
Keith FurutaniKeith Furutani
Keith Furutani
MYMasashi Yagi
Masashi Yagi
SHShannon Hartzell
Shannon Hartzell
BLBo Lu
Bo Lu
Objective. This study aims to develop and validate a pencil beam (PB) algorithm for computing Mayo Clinic Florida microdosimetric kinetic model (MCF MKM)-based relative biological effectiveness (RBE) weighted doses in carbon-ion radiotherapy (CIRT), and to compare its accuracy and efficiency against Monte Carlo (MC) simulations using real patient computed tomography (CT) data. Approach. A PB algorithm was implemented to calculate both physical and microdosimetric parameters—using the abridged microdosimetry distribution methodology (AMDM)—for the MCF MKM model, and subsequently the RBE-weighted dose. Four clinical cases (brain, head and neck, lung and prostate) were planned in-house and computed using the PB algorithm and tool for particle simulation (TOPAS) MC simulations. Dose-volume histograms (DVHs), dose profiles, gamma analysis, and computational times were compared. Monochromatic and polychromatic AMDM kernels were also evaluated to assess any impact on RBE dose distributions. Main results. Except for the lung case, the PB algorithm showed strong agreement with TOPAS MC simulations, with gamma passing rates over 98% at 3%/3 mm and around 90% at 2%/2 mm for the other three cases. DVHs and dose profiles also closely matched. In the lung case, agreement was lower—87.6% at 3%/3 mm and 77.1% at 2%/2 mm—due to PB’s limitations in modeling Coulomb scattering in heterogeneous lung tissue. Still, PB calculations were completed in minutes, highlighting its potential for fast, clinically viable RBE dose evaluation. Significance. This study presents the first complete demonstration of an MCF MKM-based RBE dose calculation using a PB algorithm on actual patient CT data, providing a robust balance between accuracy and computational efficiency. Although limitations in PB modeling may introduce larger discrepancies in highly heterogeneous anatomical regions and sites, the overall performance and speed underscore the method’s viability for routine clinical CIRT planning.

1 October 2017 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Verified
Journal Article
Open access
PDF file
TCT.D. Chiu
T.D. Chiu
JTJ. Tan
J. Tan
TLT. Long
T. Long
BZBo Zhao
Bo Zhao
Kenneth WestoverKenneth Westover
Kenneth Westover
XGXuejun Gu
Xuejun Gu
Electron therapy offers distinct advantages for the treatment of superficial tumors although dosimetry can be difficult to precisely control without custom compensating devices. Previously the manufacture of such devices utilized resource intensive processes such as CNC (computer-numerical-control) machining or resulted in hard plastic compensators that are unacceptable for many clinical situations such as placement of the compensator on complex surfaces with skin defects. To overcome these problems we developed a dosimetric-driven platform to construct patient-specific 3D soft compensators out of cast silicone to enable modulated electron radiotherapy.

7 February 2026 in Technical Innovations & Patient Support in Radiation Oncology
Verified
Journal Article
Open access
Ethan StolenEthan Stolen
Ethan Stolen
SYSridhar Yaddanapudi
Sridhar Yaddanapudi
HQHelen Qian
Helen Qian
SYSang Kyun Yoo
Sang Kyun Yoo
BLBo Lu
Bo Lu
JSJames J. Sohn
James J. Sohn
Carbon ion radiotherapy (CIRT) facilities face scheduling challenges due to multiple treatment rooms sharing a single synchrotron, leading to extended patient wait times and reduced efficiency. This study developed and evaluated an optimization tool for patient scheduling in multi-gantry CIRT facilities to minimize in-room patient wait time and maximize patient throughput. A simulation–optimization model was created to emulate patient flow in a facility with one fixed-beam and three gantry rooms. We developed a genetic algorithm (GA) to balance competing objectives like wait times, room utilization, and treatment priority. Its performance was evaluated against baseline scheduling and a Bayesian optimization (BO) approach, using metrics of average in-room wait time and algorithm execution speed. Robustness was tested across various scenarios, including equipment downtime. The GA reduced average patient wait times by 17% (from 0.47 to 0.39 min) compared to baseline. BO performed significantly better, achieving a 92% reduction (to 0.04 min). While GA converged faster (3 min), BO required more iterations to converge, thereby taking longer (7 min), but achieving much greater reduction in average patient wait times. In 100 independent test scenarios, the BO approach significantly reduced wait times in 100% of the simulations, compared to 19% for the GA. Both algorithms maintained robust performance across diverse conditions, demonstrating their reliability. Analysis of outliers (N = 100) showed that BO significantly reduced the maximum patient wait time from 3.52 to 1.33 min (p < 0.001), minimizing clinically relevant extremes. This application of scheduling optimization to the unique constraints of CIRT shows potential for improving efficiency at CIRT facilities. While requiring minutes rather than seconds to converge, the BO algorithm effectively eliminates immobilized wait times, making it a powerful tool for daily schedule optimization. Future research will focus on validation with empirical data from operational CIRT centers.