Robert Weih

Robert Weih

Auto-generated profile, based on publicly available information

Robert Weih

Nanoplus Advanced Photonics Gerbrunn GmbH 2 , Oberer Kirschberg 4, 97218 Gerbrunn, Germany

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 June 2024 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
BPB. Petrović
B. Petrović
ABA. Bader
A. Bader
JNJ. Nauschütz
J. Nauschütz
TST. Sato
T. Sato
SBS. Birner
S. Birner
SHS. Höfling
S. Höfling
We present an interband cascade laser (ICL) emitting at 5.2 µm consisting of an 8-stage active region and a hybrid cladding composed of outer plasmon-enhanced InAs0.915Sb0.085 and inner InAs/AlSb superlattice claddings. The hybrid cladding architecture shows an increase in mode confinement in the active region by 11.2% according to the simulation. This is a consequence of a significantly lower refractive index of plasmon-enhanced claddings. The threshold current density is 242 A/cm2 in pulsed operation at room temperature. This is the lowest value reported to date for ICLs emitting at wavelengths longer than 5 µm. We also report close to record value threshold power density of 840 W/cm2 for ICLs at such wavelengths.

12 December 2013 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
FJFilip Janiak
Filip Janiak
MMMarcin Motyka
Marcin Motyka
Grzegorz SękGrzegorz Sęk
Grzegorz Sęk
MDMateusz Dyksik
Mateusz Dyksik
KRKrzysztof Ryczko
Krzysztof Ryczko
GPGilles Patriarche
Gilles Patriarche
Optical properties of molecular beam epitaxially grown type II “W” shaped GaSb/AlSb/InAs/GaIn(As)Sb/InAs/AlSb/GaSb quantum wells (QWs) designed for the active region of interband cascade lasers have been investigated. Temperature dependence of Fourier-transformed photoluminescence and photoreflectance was employed to probe the effects of addition of arsenic into the original ternary valence band well of GaInSb. It is revealed that adding arsenic provides an additional degree of freedom in terms of band alignment and strain tailoring and allows enhancing the oscillator strength of the active type II transition. On the other hand, however, arsenic incorporation apparently also affects the structural and optical material quality via generating carrier trapping states at the interfaces, which can deteriorate the radiative efficiency. These have been evidenced in several spectroscopic features and are also confirmed by cross-sectional transmission electron microscopy images. While arsenic incorporation into type II QWs is a powerful heterostructure engineering tool for optoelectronic devices, a compromise has to be found between ideal band structure properties and high quality morphological properties.

1 December 2024 in AIP Advances
Verified
Journal Article
Open access
PDF file
AFA. Femenias
A. Femenias
MEM. Erdem
M. Erdem
Polina FominaPolina Fomina
Polina Fomina
JSJ. Scheuermann
J. Scheuermann
UBU. Blazhko
U. Blazhko
BMBoris Mizaikoff
Boris Mizaikoff
Interband cascade lasers (ICL) are high output power mid-infrared light sources with low power consumption, serving as a viable alternative to more commonly applied quantum cascade lasers. The integration of ICLs with thin-film waveguides facilitates miniaturized sensing platforms based on the principles of evanescent field absorption toward tailorable high-fidelity portable mid-infrared (MIR) sensing solutions for on-site chemical analysis. The analytical performance of a MIR sensing system is presented combining a tunable interband cascade laser emitting at a wavelength range of 5.88–6.09 µm (1702–1641 cm−1) with a 6 µm GaAs/AlGaAs thin-film waveguide as the active transducer for customized evanescent field absorption analysis of food contaminants. A comparison of the analytical performance of the developed tICL-based system vs conventional Fourier-transform infrared spectroscopy is presented for the exemplary analysis of the Fusarium mycotoxin deoxynivalenol, a persistent food contaminant resulting from fungal infection. The thin-film waveguide enhances the sensitivity compared to conventional attenuated total reflection systems, revealing improved detection limits. The compact design of the system, along with the favorable analytical figures-of-merit and automated data processing, confirm the potential of the developed tICL-based spectrometer for on-site detection of food contaminants at various stages along the food supply chain.

23 October 2017 in Applied Physics Letters
Verified
Journal Article
Open access
APAndreas Theo Pfenning
Andreas Theo Pfenning
GKGeorg Knebl
Georg Knebl
FHFabian Hartmann
Fabian Hartmann
RWRobert Weih
Robert Weih
MMManuel Meyer
Manuel Meyer
SHSven Höfling
Sven Höfling
We investigate the electronic transport properties of GaSb/AlAsSb double barrier resonant tunneling diodes with pseudomorphically grown ternary GaAsxSb1-x emitter prewells over a broad temperature range. At room temperature, resonant tunneling is observed and the peak-to-valley current ratio (PVCR) is enhanced with the increasing As mole fraction from 1.88 (GaAs0.07Sb0.93 prewell), to 2.08 (GaAs0.09Sb0.91 prewell) up to 2.36 (GaAs0.11Sb0.89 prewell). The rise in PVCR is attributed to an enhanced carrier density at the Γ -valley within the emitter prewell. On the contrary at cryogenic temperatures, increasing the As mole fractions reduces the PVCR. At a temperature of T=4.2  K, reference samples without incorporation of an emitter prewell containing As show PVCRs up to 20.4 . We attribute the reduced PVCR to a degraded crystal quality of the resonant tunneling structure caused by As incorporation and subsequently an enhanced defect scattering at the interfaces.

9 December 2024 in Applied Physics Letters
Verified
Journal Article
Open access
MPMikołaj Piotrowski
Mikołaj Piotrowski
AWAndreas Windischhofer
Andreas Windischhofer
JFJohannes Fuchsberger
Johannes Fuchsberger
EAElena Arigliani
Elena Arigliani
MDMauro David
Mauro David
BSBenedikt Schwarz
Benedikt Schwarz
Interband cascade lasers (ICLs) are becoming increasingly valuable in mid-infrared applications due to their low power consumption and compatibility with silicon photonic integration, particularly for trace gas sensing. ICLs have demonstrated room-temperature continuous-wave operation in the 3–6 μm range, with excellent performance around 3.3 μm. A key factor limiting ICL performance at longer wavelengths is optical loss, i.e., caused by the intervalence band transitions. These losses increase with hole concentration in the active region, leading to a pronounced current-dependence of the optical losses in ICLs. Conventional methods that infer optical losses from length-dependent variations in parameters such as slope efficiency or threshold current require the assumption of constant optical loss. In this study, we present a direct optical transmission measurement technique to determine waveguide losses. Our experiments confirm strongly increasing waveguide losses with current density, directly impacting the quantum efficiency of ICLs. This approach offers a precise evaluation of optical losses and bears a functional alternative compared to traditional methods, addressing the limitations of assuming constant losses and providing enhanced insight into ICL performance across various wavelengths.

1 October 2024 in APL Photonics
Verified
Journal Article
Open access
PDF file
GMGeorg Marschick
Georg Marschick
SIStefania Isceri
Stefania Isceri
RSRolf Szedlak
Rolf Szedlak
HMHarald Moser
Harald Moser
JWJohannes Paul Waclawek
Johannes Paul Waclawek
BSBenedikt Schwarz
Benedikt Schwarz
We present a compact vertically emitting ring interband cascade laser (ICL) with low power consumption and the possibility for seamless integration into various CO2 sensing applications. Our devices exhibit desirable performance characteristics in battery-driven handheld devices, including room temperature (20 °C) threshold currents as low as 15 mA, small footprints, and stable single-mode emission, suitable for rapid isotope-resolved CO2 detection. Through epi-down bonding with sub-micron accuracy, we achieved robust integration of substrate-emitting ring ICLs, ensuring reliability and scalability that would be required for mass production. We present comprehensive experimental results validating the efficacy of our approach, including spectral analysis and CO2 sensing capabilities with limits of detection of 24 and 13 ppmv utilizing the 12CO2 P(60) and 13CO2 R(10) transitions in the ν3 fundamental band, respectively. The demonstrated devices hold great promise for a wide range of industrial applications, including environmental monitoring, process control, and atmospheric research, where compact low-power sensors are essential.