13 September 2023 in The Journal of Engineering
HKHeli Kokkoniemi‐Tarkkanen
Heli Kokkoniemi‐Tarkkanen
5G network slicing is promising in prioritizing time‐critical protection communication in wireless networks of smart grids. However, network slicing offered by telecommunication providers encompasses all smart grid applications, lacking granularity. Smart grid automation standards provide recommendations on prioritization of protection communication to improve reliability but only for wired connections. Therefore, this paper investigates hierarchical token bucket (HTB) traffic shaping and uplink (UL) bitrate adaptation of a live video stream for prioritizing protection communication within a 5G slice. An experimental setup combines controller‐hardware‐in‐the‐loop (CHIL) with a quality of service (QoS) measurement system for validation. The system under test consists of commercial 5G networks, intelligent electronic devices (IEDs), and merging units for validation with three smart grid applications: fault location, line differential, and intertrip protection. HTB traffic shaping improves protected faults by 47.57% in congested and 1.16% in non‐congested scenarios. UL bitrate of the video stream adaptation by 2 Mbps increases protected faults by 3.69%. HTB traffic shaping even improves prioritization with a wired connection without introducing additional delays. HTB traffic shaping must be deployed in routers to maintain good QoS for critical applications. Collaboration between utilities and telecommunication providers is essential to effectively deploy 5G network slicing on smart grids.
29 December 2023 in IET Cyber-Physical Systems: Theory & Applications
In recent years, cyber security‐related studies in the power grid have drawn wide attention, with much focus on its detection, mainly for data injection type of attacks. The vulnerability of power components as a result of attack and their impact on generator dynamics have been largely ignored so far. With the aim of addressing some of these issues, the authors propose a novel approach using real‐time sliding surface‐based switching attack (SA) construction. This approach targets the circuit breaker, excitation system, and governor system of the generator. The vulnerability of these power components to cyber‐physical attacks and assessment of their potential impact on the stability of generator are discussed. The study is presented to show the progression of cascading generator dynamics on account of single or multiple time instants of SA launched on these power components. The results are discussed according to criteria in terms of deviations in rotor speed of the generator and identify some of possible combinations of power components that are most critical to grid stability. The proposed study is implemented on standard IEEE 3‐machine, 9‐bus network in real‐time digital simulator via transmission control protocol/internet protocol (TCP/IP) communication network established as cyber‐physical system. The sliding surface‐based SA algorithm developed in MATLAB is launched from another computer.
30 September 2023 in International Transactions on Electrical Energy Systems
Integration of large-scale distributed photovoltaic (PV) generation resources can lead to technical challenges, particularly voltage rise caused by PVs power injection at the time of high solar radiation profile and low load demand. Reactive power control of PV inverters can help mitigate the voltage rise, which arises just for a short duration due to high incident solar radiation. There is a possibility to control functions on these PV inverters based on the rating of the PV inverter. For one-second resolution, local data-driven voltage sensitivity estimation is applied to update the control functions such as volt-var and volt-watt on the PV inverters so as to regulate the bus voltage. Different forms of solar radiation profiles, transient varying, smooth varying, and worst operating scenario corresponding to the minimum load at the time of high PV generation, are included. The study is demonstrated for different PV penetration levels. The voltage analysis on buses is performed using power hardware (PV emulator) in the loop simulation, at one of the buses in the network, while the remaining PVs are being controlled using volt-var control (VVC)/volt-watt control (VWC) methods. The applied approach confirms to maintaining bus voltage within limits even against a very short transient time instant of solar radiation profile.
1 January 2026 in IET Generation, Transmission & Distribution
HKHeli Kokkoniemi‐Tarkkanen
Heli Kokkoniemi‐Tarkkanen
The growing penetration of renewables and prosumagers in the 2030s will require deeper monitoring and control in medium‐ and low‐voltage grids. Wireless technologies, particularly 5G, offer possibilities for cost‐effective, flexible, and scalable connectivity in grid automation. Power system communication is highly heterogeneous, involving diverse traffic types with varying latency and reliability requirements. Prior research on 5G technology enablers, such as carrier aggregation, dual connectivity, and network slicing (NS), has focused on other verticals and relied mainly on simulations, leaving a gap in experimental validation for grid protection and automation under realistic conditions. This paper maps 5G technology enablers to IEC 61850 traffic types and evaluates their performance in commercial 5G networks for line differential protection and virtualised fault passage indication. Results show that NS improves reliability compared to traffic prioritisation, but does not yet meet ultra‐low latency requirements for line differential protection. Minimum latency for mission‐critical protection traffic reaches approximately 11 ms, and round‐trip times are 32% lower than prior works. These findings provide the first end‐to‐end empirical evidence of 5G technology enabler deployment for smart grid applications and offer practical guidance for future implementations.