Mohammad Shadman Ishrak

Mohammad Shadman Ishrak

Auto-generated profile, based on publicly available information

Mohammad Shadman Ishrak

Department of Electrical and Computer Engineering, University of Hawaii at Mnoa, Honolulu, HI, USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 May 2025 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Open access
MIMohammad Shadman Ishrak
Mohammad Shadman Ishrak
JSJannatun Noor Sameera
Jannatun Noor Sameera
OBOlga Boric-Lubecke
Olga Boric-Lubecke
VLVictor Manuel Lubecke
Victor Manuel Lubecke
Doppler radar systems can demonstrably provide accurate measurement of physiological motion for sedentary and partially sedentary subjects. In this research, quadrature and single-channel demodulation techniques are evaluated and their performance is compared for the extraction of vital-signs-related displacement and rate information from clutter and noise. Computational complexity, degree of displacement waveform correlation, and spectral analysis resolution are taken into account. The demodulation techniques were tested by synthesizing realistic cardiorespiratory motion using a robotic mover, and with human data. Arctangent demodulation (AD) and linear demodulation (LD) were demonstrated to be computationally more efficient than the other methods, and AD provided phase information needed for accurate quantitative tracking of the measured displacement waveform. Divide and cross multiply (DACM) methods were found to have a greater resilience against noise when recovering cardiac rate information, while discrete cosine transform (DCT) methods demonstrated greater frequency resolution over shorter segments of data when making respiratory measurements. These findings provide important guidance when selecting a demodulation method that is best suited for a particular measurement system or application.

18 June 2025 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Open access
Khaldoon IshmaelKhaldoon Ishmael
Khaldoon Ishmael
Shekh Md Mahmudul IslamShekh Md Mahmudul Islam
Shekh Md Mahmudul Islam
MIMohammad Shadman Ishrak
Mohammad Shadman Ishrak
JSJannatun Noor Sameera
Jannatun Noor Sameera
RORichard C. Ordoñez
Richard C. Ordoñez
OBOlga Boric-Lubecke
Olga Boric-Lubecke
Uncrewed aerial vehicles (UAVs) equipped with Doppler radar for remote life sensing have the potential to offer an effective solution for search and rescue applications. Interference introduced by the moving UAV platform can, however, obscure human vital signs. A dual 24-GHz radar noise compensation (DRNC) system is proposed with two motion compensation methods: adaptive noise cancellation (ANC) and net signal interference cancellation (NIC). Arctangent-demodulated platform motion reference signals are used to enable accurate recovery of respiration displacement. The proposed methods have been validated with a robotic mover and a human subject, showing a motion frequency error of less than 1% and a respiration displacement error of less than 10%. The respiration displacement error was a fraction of 1 mm, even in the presence of a platform motion that exceeded 100 mm. To the best of the authors’ knowledge, this is the first use of arctangent demodulation for ANC motion reference and the first UAV in-flight measurement of human respiration displacement.

31 July 2025 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Open access
MIMohammad Shadman Ishrak
Mohammad Shadman Ishrak
JSJannatun Noor Sameera
Jannatun Noor Sameera
AYAlvin Yang
Alvin Yang
YPYanjun Pan
Yanjun Pan
YZYao Zheng
Yao Zheng
VLVictor Manuel Lubecke
Victor Manuel Lubecke
A 28-GHz multibeam joint communication and sensing system called SideSense is presented, in which a line-of-sight (LoS) beam is used to maintain reliable communication, while other sensing beams are used to enhance physiological motion detection. SideSense decodes the motion frequency and shape from the channel state information (CSI) by first tuning the gain ratio and phase differences between the LoS communication beam and non-LoS (NLoS) beam to maximize the sensing signal-to-noise ratio (SSNR) without significantly degrading the communication channel capacity (CCC). Analytical results based on a bistatic model are presented to show a gain ratio of around 1 and a phase difference of 90° or 270°, which are ideal for optimizing both SSNR and CCC. Experiments based on an array of phased array (APA) beamformers and orthogonal frequency-division multiplexing (OFDM) waveforms with phantom and human subjects are presented to validate the performance of SideSense. Results show that SideSense can improve SSNR by 84% while reducing CCC by 35%, an acceptable decrease within the normal operational parameters of a millimeter-wave (mmWave) communication system, which would not trigger a link reestablishment procedure, e.g., communication beam realignment.

24 July 2023 in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Verified
Conference Paper
Open access
MIMohammad Shadman Ishrak
Mohammad Shadman Ishrak
JSJannatun Noor Sameera
Jannatun Noor Sameera
OBOlga Boric-Lubecke
Olga Boric-Lubecke
VLVictor Manuel Lubecke
Victor Manuel Lubecke
Accurate continuous measurement of respiratory displacement using continuous wave Doppler radar requires rigorous management of dc offset which changes when a subject changes distance from the radar measurement system. Effective measurement, therefore, requires robust dynamic calibration which can recognize and compensate for changes in the nominal position of a subject. In this paper, a respiratory displacement measurement algorithm is proposed which can differentiate between sedentary and non-sedentary conditions and continuously adapt to provide long-term monitoring of a subject’s sedentary respiration. Arctangent demodulation is an effective means of quantifying continuous displacement using a quadrature Doppler radar, yet it depends on accurate identification of dc offset and dc information contributions in the radar I-Q arc with the subject in a particular position. The dynamic calibration method proposed here is demonstrated to differentiate between sedentary and non-sedentary conditions for six subjects to produce accurate sedentary respiration measurements even when the subject arbitrarily changes position, once the appropriate thresholds are established for the measurement environment.