Bernhard Hoffschmidt

Bernhard Hoffschmidt

Auto-generated profile, based on publicly available information

Bernhard Hoffschmidt

German Aerospace Center (DLR), Institute of Solar Research, 52428 Juelich, Germany

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 January 2003 in Journal of Solar Energy Engineering
Verified
Journal Article
Closed access
PDF file
BHBernhard Hoffschmidt
Bernhard Hoffschmidt
FTFe´lix M. Te´llez
Fe´lix M. Te´llez
AVAntonio Valverde
Antonio Valverde
JFJesu´s Ferna´ndez
Jesu´s Ferna´ndez
VFValerio Ferna´ndez
Valerio Ferna´ndez
The High Temperature Receiver (HitTRec) consists of a modular ceramic absorber, a supporting structure and an air-return system. It has been designed to prevent possible flow instability at 700-800°C average outlet air temperature with atmospheric pressure. The HiTRec-II prototype was developed to solve the structural problems of the first prototype (HiTRec-I). Testing in the Plataforma Solar de Almerı´a (PSA) test bed lasted from November 2000 through May 2001, accumulating 150 test hours under concentrated sun. Results demonstrated the durability of the modified stainless-steel structure. Inlet aperture flux was up to 900kW/m2 and average outlet air temperatures of up to 840°C with peak outlet air temperatures of up to 950°C. Thermal efficiency under steady-state conditions was 76±7% at 700°C, nominal conditions for a PHOEBUS-type volumetric receiver. Other performance characteristics were also evaluated (e.g., Air Return Ratio of 46% and characteristic receiver response time of 70 s).

8 November 2018 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
PDF file
KWKai Wieghardt
Kai Wieghardt
DLDmitrij Laaber
Dmitrij Laaber
VDVolkmar Dohmen
Volkmar Dohmen
PHPatrick Hilger
Patrick Hilger
DKDaniel Korber
Daniel Korber
BHBernhard Hoffschmidt
Bernhard Hoffschmidt
As of now the worldwide solar research community has a unique new tool: Synlight is a high-flux solar simulator of a new performance category. It bridges the gap between laboratory scale tests and demonstration, and offers large-scale testing opportunities for up to three independently operating test campaigns. Following the commissioning and opening in March, 2017, the facility has been validated recently. The gained results met or exceeded the expectations from simulation and prototype. In particular, solar radiation powers of up to 310kW with a simultaneous peak flux of 12.5MW/m2 could be measured.

26 August 2021 in Buildings
Verified
Journal Article
Open access
PDF file
PGPhilip Gorzalka
Philip Gorzalka
JSJacob Estevam Schmiedt
Jacob Estevam Schmiedt
CSChristian Schorn
Christian Schorn
BHBernhard Hoffschmidt
Bernhard Hoffschmidt
An approach to automatically generate a dynamic energy simulation model in Modelica for a single existing building is presented. It aims at collecting data about the status quo in the preparation of energy retrofits with low effort and costs. The proposed method starts from a polygon model of the outer building envelope obtained from photogrammetrically generated point clouds. The open-source tools TEASER and AixLib are used for data enrichment and model generation. A case study was conducted on a single-family house. The resulting model can accurately reproduce the internal air temperatures during synthetical heating up and cooling down. Modelled and measured whole building heat transfer coefficients (HTC) agree within a 12% range. A sensitivity analysis emphasises the importance of accurate window characterisations and justifies the use of a very simplified interior geometry. Uncertainties arising from the use of archetype U-values are estimated by comparing different typologies, with best- and worst-case estimates showing differences in pre-retrofit heat demand of about ±20% to the average; however, as the assumptions made are permitted by some national standards, the method is already close to practical applicability and opens up a path to quickly estimate possible financial and energy savings after refurbishment.

5 November 2022 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Closed access
CFCathy Frantz
Cathy Frantz
RBReiner Buck
Reiner Buck
MRMarc Röger
Marc Röger
BHBernhard Hoffschmidt
Bernhard Hoffschmidt


15 July 2024 in Buildings
Verified
Journal Article
Open access
PDF file
LWLukas Anselm Wille
Lukas Anselm Wille
BSBjörn Schiricke
Björn Schiricke
KGKai Gehrke
Kai Gehrke
BHBernhard Hoffschmidt
Bernhard Hoffschmidt
We study the potential of infrared (IR) heaters in combination with IR reflective walls to reduce heating energy demand in buildings. Using IR heaters increases radiant temperature. Combined with IR reflective walls, less radiant heat is absorbed by the surrounding walls, and more is reflected to and absorbed by the occupants. This allows for lower air temperatures while maintaining constant thermal comfort. Lower air temperatures result in heating energy savings. In simulations, we examine the impact of four parameters on the thermal comfort indicator Predicted Mean Vote (PMV): wall temperature, inlet air temperature, IR heater power, and IR emissivity of the walls. To reduce the number of data points needed, we use a Central Composite Design for the layout of the simulation plan. The results show that the PMV can be changed from 0.15 to 1.16 only by lowering the emissivity of the surrounding walls from 0.9 to 0.1. At high IR heater power and at low wall temperature the impact of the emissivity on the PMV becomes larger. From the simulation data, we derive a response surface function to determine the required IR heating power for any given room conditions, which could be used for automated IR heater control.