Ryan Avery

Ryan Avery

Auto-generated profile, based on publicly available information

Ryan Avery

Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL 60611, USA

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 March 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
HBHaben Berhane
Haben Berhane
MSMichael Scott
Michael Scott
MEMohammed Elbaz
Mohammed Elbaz
KJKelly Jarvis
Kelly Jarvis
PMPatrick McCarthy
Patrick McCarthy
MMMichael Markl
Michael Markl

26 October 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
APAshitha Pathrose
Ashitha Pathrose
LMLiliana Ma
Liliana Ma
HBHaben Berhane
Haben Berhane
MSMichael B. Scott
Michael B. Scott
KCKelvin Chow
Kelvin Chow
MMMichael Markl
Michael Markl

5 April 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
HBHaben Berhane
Haben Berhane
MSMichael B. Scott
Michael B. Scott
ABAlex J. Barker
Alex J. Barker
PMPatrick McCarthy
Patrick McCarthy
RARyan Avery
Ryan Avery
MMMichael Markl
Michael Markl
Purpose: To develop a convolutional neural network (CNN) for the robust and fast correction of velocity aliasing in 4D‐flow MRI.Methods: This study included 667 adult subjects with aortic 4D‐flow MRI data with existing velocity aliasing (n = 362) and no velocity aliasing (n = 305). Additionally, 10 controls received back‐to‐back 4D‐flow scans with systemically varied velocity‐encoding sensitivity (vencs) at 60, 100, and 175 cm/s. The no‐aliasing data sets were used to simulate velocity aliasing by reducing the venc to 40%–70% of the original, alongside a ground truth locating all aliased voxels (153 training, 152 testing). The 152 simulated and 362 existing aliasing data sets were used for testing and compared with a conventional velocity antialiasing algorithm. Dice scores were calculated to quantify CNN performance. For controls, the venc 175‐cm/s scans were used as the ground truth and compared with the CNN‐corrected venc 60 and 100 cm/s data setsResults: The CNN required 176 ± 30 s to perform compared with 162 ± 14 s for the conventional algorithm. The CNN showed excellent performance for the simulated data compared with the conventional algorithm (median range of Dice scores CNN: [0.89–0.99], conventional algorithm: [0.84–0.94], p < 0.001, across all simulated vencs) and detected more aliased voxels in existing velocity aliasing data sets (median detected CNN: 159 voxels [31–605], conventional algorithm: 65 [7–417], p < 0.001). For controls, the CNN showed Dice scores of 0.98 [0.95–0.99] and 0.96 [0.87–0.99] for venc = 60 cm/s and 100 cm/s, respectively, while flow comparisons showed moderate‐excellent agreement.Conclusion: Deep learning enabled fast and robust velocity anti‐aliasing in 4D‐flow MRI.

1 November 2022 in JCO Clinical Cancer Informatics
Verified
Journal Article
Closed access
MSMOATAZ ahmed sayed SOLIMAN
MOATAZ ahmed sayed SOLIMAN
LKLinda C. Kelahan
Linda C. Kelahan
MMMichael Magnetta
Michael Magnetta
HSHatice Savas
Hatice Savas
RARishi Agrawal
Rishi Agrawal
YVYuri S. Velichko
Yuri S. Velichko
PURPOSE: Variability in computed tomography images intrinsic to individual scanners limits the application of radiomics in clinical and research settings. The development of reproducible and generalizable radiomics-based models to assess lesions requires harmonization of data. The purpose of this study was to develop, test, and analyze the efficacy of a radiomics data harmonization model. MATERIALS AND METHODS: Radiomic features from biopsy-proven untreated hepatic metastasis (N = 380) acquired from 167 unique patients with pancreatic, colon, and breast cancers were analyzed. Radiomic features from volume-match 551 samples of normal liver tissue and 188 hepatic cysts were included as references. A novel linear mixed effect model was used to identify effects associated with lesion size, tissue type, and scanner model. Six separate machine learning models were then used to test the effectiveness of radiomic feature harmonization using multivariate analysis. RESULTS: Proposed model identifies and removes scanner-associated effects while preserving cancer-specific functional dependence of radiomic features on the tumor size. Data harmonization improves the performance of classification models by reducing the scanner-associated variability. For example, the multiclass logistic regression model, LogitBoost, demonstrated the improvement in sensitivity in the range from 15% to 40% for each type of liver metastasis, whereas the overall model accuracy and the kappa coefficient increased by 5% and 8% accordingly. CONCLUSION: The model removed scanner-associated effects while preserving cancer-specific functional dependence of radiomic features.

1 March 2025 in RadioGraphics
Verified
Journal Article
Closed access
RCRoberta Catania
Roberta Catania
SQSandra Quinn
Sandra Quinn
ARAmir A. Rahsepar
Amir A. Rahsepar
TTTugce Agirlar Trabzonlu
Tugce Agirlar Trabzonlu
JBJay Bharatsingh Bisen
Jay Bharatsingh Bisen
BABradley D Allen
Bradley D Allen
Quantitative stress perfusion cardiac magnetic resonance (CMR) imaging is an emerging and powerful clinical tool that improves the diagnostic accuracy of stress perfusion CMR for noninvasive assessment of epicardial coronary artery disease, microvascular dysfunction, aortic stenosis, and cardiac allograft vasculopathy.

4 May 2022 in Diagnostic and Interventional Imaging
Verified
Journal Article
Closed access
GSGilles Soulat
Gilles Soulat
MSMichael B Scott
Michael B Scott
APAshitha Pathrose
Ashitha Pathrose
KJKelly Jarvis
Kelly Jarvis
HBHaben Berhane
Haben Berhane
MMMichael Markl
Michael Markl