In this article, a discrete-time sensorless current control for permanent magnet synchronous motors with an accuracy-improved phase-locked loop is proposed. The proposed current control method is designed directly in the discrete-time domain, which guarantees the control performance in digital implementations. In the proposed scheme, a discrete-time double-vector model is constructed for permanent magnet synchronous motor (PMSM). Then, the complex principle-based discrete-time current regulator is extended to PMSM with better performance and higher robustness. In order to reduce the error between the estimated and actual back electromotive force (back-EMF), a discrete-time sliding-mode back-EMF observer is designed based on an exact discretized state-space model. Then according to the rotational mode of the back-EMF in the discrete synchronous reference frame, a fully discretized back-EMF model is established with the angular error between the estimated angle and the actual angle. Based on the back-EMF model, the proposed phase-locked loop (PLL) can estimate the electrical angle more accurately. The angular error which increases with the rising speed in the conventional angle estimation method is suppressed by the proposed PLL. Finally, the comparative experiments verify the effectiveness of the proposed method.
24 July 2023 in IEEE Transactions on Power Electronics
In permanent magnet synchronous motor (PMSM) drives, the rotor position signal is critical. However, the failure of the mechanical position sensor and the position tracking error of the resolver-to-digital conversion (RDC) causes position signal biases. These position biases significantly deteriorate motor drive performance, while there are few effective methods to handle both biases simultaneously. To uniformly and accurately compensate for these biases, a back electromotive force (back-EMF)-based discrete-time rotor position bias compensation method for PMSMs is proposed, which includes improvements in compensation accuracy and algorithm execution efficiency. In the proposed scheme, an adaptive disturbance observer with multi-parameter estimation is designed to estimate the back-EMF. The proposed multi-parameter estimation is designed based on the decomposed voltage vector of the current regulator. Compared with widely used recursive-least-square (RLS) methods, the proposal greatly reduces the computational burden. Then according to the rotational mode of the back-EMF in the discrete synchronous reference frame, an exactly discretized back-EMF model is established. Based on this model, a discrete-time compensation method for rotor position bias is proposed. Compared with the continuous-time back-EMF model-based method, the proposal can suppress the estimated error between actual and estimated bias, which rises with increasing motor speed. Finally, the experiments are carried out to verify the effectiveness of the proposed method.
8 March 2023 in IEEE Transactions on Transportation Electrification
An axial-parallel hybrid excitation machine (APHEM) with an auxiliary winding is proposed and investigated for loss reduction in the flux-weakening operation. The permanent magnet (PM) flux and wound field flux of the APHEM are different and coupled under the armature action. Based on the axial-parallel structure, an auxiliary winding is introduced into the PM part to make better utilization of the distinct PM flux. Because of the coupling of the two fields, this auxiliary winding not only couples the PM flux but also affects the wound field flux. Two major conclusions can be derived from the theoretical analysis. Firstly, the auxiliary winding couples the PM flux and produces extra torque, benefiting a smaller field current. Secondly, the auxiliary winding can suppress the phase voltage because of the larger characteristic current of the PM part than the wound field part. This facilitates a smaller d-axis armature current. The reduced currents favor the reduction in copper loss and core loss. Compared with the original APHEM under the minimum-copper-loss control, the proposed method achieves a 34% reduction in the maximum loss and a 60% decline in the maximum torque ripple ratio. Finally, the measured results verify the analysis.
12 October 2023 in IEEE Transactions on Transportation Electrification
Oil cooling technique is one of the important ways to reduce the temperature rise and enhance the power density of aircraft electric machines. However, high viscosity of the oil leads to high flow resistance, which may reduce the efficiency of the hydraulic system and damage the components. This paper conducts research on the flow resistance characteristics of cooling channels. Firstly, considering computational efficiency and accuracy, the influence of mesh type, size, and boundary layers on the cell count and calculation results is compared and summarized. Then, Computational Fluid Dynamics (CFD) models for the series cooling channel and split-flow cooling channel are established. Another split-flow method is explored to optimize the cooling channel. Based on CFD and theoretical formulas, the influence mechanism of channel type and flow rate on flow resistance is revealed. Further, the Heat-pressure ratio ( HPr ) is defined as an indicator to evaluate the heat dissipation capability of cooling structures. Finally, the pressure test models are constructed by 3D printing. The experiments verify the correctness of analysis. The optimization methods can reduce flow resistance by 80.4% and increase Heat Transfer Coefficient by 44% at the same pressure. The HPr can serve as a reference for evaluating cooling structures.
23 January 2024 in IEEE Journal of Emerging and Selected Topics in Power Electronics
A discrete-time sensorless current control method is proposed for the interior permanent magnet synchronous motor (IPMSM) in this paper. Due to the inconsistent dq -axis inductance of IPMSMs, the design of the discrete-time current control method and sensorless control method is complicated. The control methods are therefore widely designed in the continuous-time domain, while the performance of these continuous-time methods is poor. In the proposed scheme, the current regulator is designed in the discrete-frequency domain based on an entirely discretized state-space model, which improves the dynamic and steady-state performance of the current control system. In terms of the electrical angle estimation method, the continuous-time model-based method leads to a significant estimation error. To improve the accuracy of the estimated back-EMF, a state-space model with a modified back-EMF (MBEMF) model is derived in the discrete-time domain. Then the observer of MBEMF and a phase-locked loop (PLL) with phase compensation are proposed based on the discrete-time state-space model. The proposal improves the accuracy of the estimated electrical angle. The proposal is designed directly in the discrete-time domain, which avoids significant performance deterioration in digital implementations. Finally, the proposed method is implemented on an IPMSM drive test rig to verify its improvement.
24 December 2024 in IEEE Journal of Emerging and Selected Topics in Power Electronics
In this article, a deadbeat predictive current control (DPCC) method based on gain factor self-tuning technology is proposed, which can effectively improve the dynamic response performance and robustness of the control system. Since the performance of DPCC is highly dependent on parameter accuracy, this paper establishes a closed-loop transfer function model of the DPCC method and analyzes in detail the impact of parameter mismatch on the current dynamic response performance. Then, the current error caused by parameter mismatch is suppressed by designing the gain factor, on this basis, a parameter self-tuning algorithm based on gradient descent optimization method is constructed. Compared with traditional parameter identification algorithms, the proposed method has the advantages of strong versatility and greatly reduces computational burden. Finally, the accuracy of the tuning results of the proposed method is proved by experimental results, which effectively suppresses the influence of parameter mismatch and improves the current response performance.