Raffaele Aaron Giampaolo

Raffaele Aaron Giampaolo

Auto-generated profile, based on publicly available information

Raffaele Aaron Giampaolo

Department of Electronics and Telecommunications, Polytechnic University of Turin, 10129 Turin, Italy

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2020 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
Lucio PancheriLucio Pancheri
Lucio Pancheri
RGRaffaele A. Giampaolo
Raffaele A. Giampaolo
ASAndrea Di Salvo
Andrea Di Salvo
SMSerena Mattiazzo
Serena Mattiazzo
TCThomas Corradino
Thomas Corradino
ARAngelo Rivetti
Angelo Rivetti
This article presents a fully depleted monolithic active pixel sensor technology compatible with a standard deep submicrometer 110-nm CMOS process. Passive test pixels structures, produced in various flavors, have proved the feasibility of 100- and 300-μm-thick active substrates. Active pixel sensors with monolithically integrated analog and digital electronics, consisting of a 24 x 24 array of pixels with 50-μm pitch, have been shown to be fully functional when operating in the full depletion mode. Characterization results obtained with a proton microbeam and a ⁵⁵Fe radiation source are presented and discussed.

22 January 2024 in Sensors
Verified
Journal Article
Open access
PDF file
TBThi Ngoc Hang Bui
Thi Ngoc Hang Bui
MLMatthew Large
Matthew Large
JPJoel Lewis Poder
Joel Lewis Poder
JBJoseph Bucci
Joseph Bucci
EBEdoardo Bianco
Edoardo Bianco
MPMarco Petasecca
Marco Petasecca
We assessed the accuracy of a prototype radiation detector with a built in CMOS amplifier for use in dosimetry for high dose rate brachytherapy. The detectors were fabricated on two substrates of epitaxial high resistivity silicon. The radiation detection performance of prototypes has been tested by ion beam induced charge (IBIC) microscopy using a 5.5 MeV alpha particle microbeam. We also carried out the HDR Ir-192 radiation source tracking at different depths and angular dose dependence in a water equivalent phantom. The detectors show sensitivities spanning from (5.8 ± 0.021) × 10−8 to (3.6 ± 0.14) × 10−8 nC Gy−1 mCi−1 mm−2. The depth variation of the dose is within 5% with that calculated by TG-43. Higher discrepancies are recorded for 2 mm and 7 mm depths due to the scattering of secondary particles and the perturbation of the radiation field induced in the ceramic/golden package. Dwell positions and dwell time are reconstructed within ±1 mm and 20 ms, respectively. The prototype detectors provide an unprecedented sensitivity thanks to its monolithic amplification stage. Future investigation of this technology will include the optimisation of the packaging technique.

1 November 2019
Verified
Conference Paper
Closed access
RGRaffaele Aaron Giampaolo
Raffaele Aaron Giampaolo
ASAndrea Di Salvo
Andrea Di Salvo
LPLucio Pancheri
Lucio Pancheri
TCTommaso Croci
Tommaso Croci
JOJonhatan Olave
Jonhatan Olave
PGPiero Giubilato
Piero Giubilato
A high-voltage monolithic active pixel sensor, designed to be compatible with standard deep sub-micron CMOS production lines, is described. The device can support a reverse bias voltage of −180 V and combines small collection electrodes with full wafer depletion, demonstrated up to a thickness of $300\ \mu \mathrm{m}$ . Test structures consisting of matrices with an area of $2\ \mathrm{mm} \times 2\ \mathrm{mm}$ embedding 576 pixels with $50\ \mu \mathrm{m}$ pitch have been fabricated in a 110 nm CMOS process. The sensor concept is discussed and experimental measurements obtained on first prototypes are presented.

4 September 2024 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
MBMattia Barbanera
Mattia Barbanera
GSGianluigi Silvestre
Gianluigi Silvestre
GAGiovanni Ambrosi
Giovanni Ambrosi
FCFabio Cossio
Fabio Cossio
MRManuel Dionisio Da Rocha Rolo
Manuel Dionisio Da Rocha Rolo
Pisana PlacidiPisana Placidi
Pisana Placidi
ASTRA-64 (Adaptable Silicon sTrip Read-out ASIC) is a 64-channel mixed-signal ASIC designed for reading out micro-strip silicon detectors. Its initial application is on serving as the read-out for the Silicon Charge Detector of the HERD experiment, slated for installation aboard the Chinese space station in 2027 to facilitate tracking and supplementary charge measurement. Designed using 110 nm technology, ASTRA-64 comprises two identical mirrored blocks, each accommodating 32 channels. Each channel integrates a Charge-Sensitive Amplifier featuring two programmable gain settings suitable for both positive and negative input signal polarities. Following this is a shaper with adjustable peaking time, allowing for noise performance optimization based on the detector capacitance. The front-end gain is calibrated to enable linear charge measurement of up to 160 fC and 80 fC depending on the gain configuration. ASTRA-64 offers two distinct readout modes. In the analog readout mode, sampled voltages are sent off-chip via an analog multiplexer linked with a differential output buffer. Conversely, the digital readout mode employs a Wilkinson ADC in each channel to digitize sampled voltages, with a shared serializer transmitting digital data through an SLVS driver. Additionally, a fast shaper, in tandem with a leading-edge hysteresis discriminator, is integrated, and the outputs of the 32 channel discriminators are merged using a FAST-OR logic to produce a rapid trigger signal off-chip. Remarkably, the ASIC’s power dissipation is kept below 600 μW per channel, aligning with stringent power consumption requirements for space applications. We will present the tests, characterization, and performance of ASTRA-64.