1 November 2018 in Fusion Engineering and Design
27 November 2023 in Plasma Physics and Controlled Fusion
This paper analyzes the neutral fluxes in the divertor region of the W7-X standard configuration for different input powers, both under attached and detached conditions. The performed analysis is conducted through EMC3-EIRENE simulations. They show the importance of the horizontal divertor to generate neutrals, and resolve the neutral plugging in the divertor region. Simulations of detached cases show a decrease in the number of generated neutrals compared to the attached simulations, in addition to a higher fraction of the ion flux arriving on the baffles during detachment. As the ionization takes place further inside the plasma during detachment, a larger percentage of the generated neutral particles leave the divertor as neutrals. The leakage in the poloidal and toroidal direction increases, just as the fraction of collected particles at the pumping gap. The fraction of pumped particles increases with a factor two, but stays below one percent. This demonstrates that detachment with the current target geometry, although it improves the power exhaust, is not yet leading to an increased particle exhaust.
1 December 2018 in Nuclear Materials and Energy
1 September 2015 in Fusion Science and Technology
The modular stellarator Wendelstein 7-X in Greifswald, Germany, is currently in the state of commissioning. The sophisticated superconducting magnet system with 50 non-planar and 10 planar coils will be operated at 4K and has to sustain high electromagnetic loads. The likewise quite complex cryostat comprises the outer vessel, plasma vessel, and 254 ports of different types connecting the plasma and outer vessels.The magnet and cryostat systems are instrumented with more than 800 strain gauges, distance, and contact sensors. Implementation and expected results of this extended mechanical instrumentation is the scope of this paper.
9 September 2023 in Nuclear Materials and Energy
1 April 2024 in Review of Scientific Instruments
The design, development, and successful implementation of pop-up Langmuir probes installed in the water-cooled divertor of W7-X are described. The probes are controlled by drive coils (actuators) installed behind the divertor plates. These drive coils make use of the magnetic field in W7-X to move the probe tips into and out of the plasma. The drive coils were installed in the vacuum vessel after extensively testing the durability of the coils and analyzing the criteria for safe operation. The probe design is carefully tailored for each of the 36 probe tips in order to be suitable for the different magnetic field configurations used in W7-X and ensure that the probes do not present leading edges to the magnetic flux tubes. An electronic bridge circuit is used for measurement to compensate for the effects of signal propagation time on the long cable lengths used. The diagnostic is integrated with the segment control of W7-X for automated operation and control of the diagnostic. The evaluation of the results from the plasma operation is presented after accounting for appropriate sheath expansion for negative bias voltage on the probes.