Bram Stieltjes

Bram Stieltjes

Auto-generated profile, based on publicly available information

Bram Stieltjes

Univ Basel, Univ Hosp Basel, Clin Radiol & Nucl Med, Basel, Switzerland

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
TWThomas Weikert
Thomas Weikert
LNLuca Andre Noordtzij
Luca Andre Noordtzij
JBJens Bremerich
Jens Bremerich
BSBram Stieltjes
Bram Stieltjes
VPVictor Parmar
Victor Parmar
ASAlexander Sauter
Alexander Sauter
Weikert T, et al. Korean J Radiol. 2020 Jul;21(7):891-899. https://doi.org/10.3348/kjr.2019.0653

1 August 2021 in European Journal of Radiology
Verified
Journal Article
Open access
LSLena Schmuelling
Lena Schmuelling
FFFabian C. Franzeck
Fabian C. Franzeck
CNChristian Hans Nickel
Christian Hans Nickel
GMGregory Mansella
Gregory Mansella
RBRoland Bingisser
Roland Bingisser
GSGregor Sommer
Gregor Sommer
Rapid communication of CT exams positive for pulmonary embolism (PE) is crucial for timely initiation of anticoagulation and patient outcome. It is unknown if deep learning automated detection of PE on CT Pulmonary Angiograms (CTPA) in combination with worklist prioritization and an electronic notification system (ENS) can improve communication times and patient turnaround in the Emergency Department (ED). In 01/2019, an ENS allowing direct communication between radiology and ED was installed. Starting in 10/2019, CTPAs were processed by a deep learning (DL)-powered algorithm for detection of PE. CTPAs acquired between 04/2018 and 06/2020 (n = 1808) were analysed. To assess the impact of the ENS and the DL-algorithm, radiology report reading times (RRT), radiology report communication time (RCT), time to anticoagulation (TTA), and patient turnaround times (TAT) in the ED were compared for three consecutive time periods. Performance measures of the algorithm were calculated on a per exam level (sensitivity, specificity, PPV, NPV, F1-score), with written reports and exam review as ground truth. Sensitivity of the algorithm was 79.6 % (95 %CI:70.8-87.2%), specificity 95.0 % (95 %CI:92.0-97.1%), PPV 82.2 % (95 %CI:73.9-88.3), and NPV 94.1 % (95 %CI:91.4-96 %). There was no statistically significant reduction of any of the observed times (RRT, RCT, TTA, TAT). DL-assisted detection of PE in CTPAs and ENS-assisted communication of results to referring physicians technically work. However, the mere clinical introduction of these tools, even if they exhibit a good performance, is not sufficient to achieve significant effects on clinical performance measures.

1 July 2016 in European Journal of Radiology
Verified
Journal Article
Closed access
MKMiriam Klauss
Miriam Klauss
PMPhilipp Mayer
Philipp Mayer
LMLena Maier-Hein
Lena Maier-Hein
FLFrederik B. Laun
Frederik B. Laun
AMArineb Mehrabi
Arineb Mehrabi
BSBram Stieltjes
Bram Stieltjes

19 May 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
LALorraine Abel
Lorraine Abel
JWJakob Wasserthal
Jakob Wasserthal
TWThomas Weikert
Thomas Weikert
ASAlexander Sauter
Alexander Sauter
INIvan Nesic
Ivan Nesic
BFBjörn Friebe
Björn Friebe
Pancreatic cystic lesions (PCL) are a frequent and underreported incidental finding on CT scans and can transform into neoplasms with devastating consequences. We developed and evaluated an algorithm based on a two-step nnU-Net architecture for automated detection of PCL on CTs. A total of 543 cysts on 221 abdominal CTs were manually segmented in 3D by a radiology resident in consensus with a board-certified radiologist specialized in abdominal radiology. This information was used to train a two-step nnU-Net for detection with the performance assessed depending on lesions’ volume and location in comparison to three human readers of varying experience. Mean sensitivity was 78.8 ± 0.1%. The sensitivity was highest for large lesions with 87.8% for cysts ≥220 mm3 and for lesions in the distal pancreas with up to 96.2%. The number of false-positive detections for cysts ≥220 mm3 was 0.1 per case. The algorithm’s performance was comparable to human readers. To conclude, automated detection of PCL on CTs is feasible. The proposed model could serve radiologists as a second reading tool. All imaging data and code used in this study are freely available online.

1 August 2021 in European Journal of Radiology
Verified
Journal Article
Open access
HBHanns C. Breit
Hanns C. Breit
KBKai T. Block
Kai T. Block
DWDavid Winkel
David Winkel
JGJulian E. Gehweiler
Julian E. Gehweiler
MHMaurice Henkel
Maurice Henkel
THTobias J. Heye
Tobias J. Heye
To evaluate potential confounding factors in the quantitative assessment of liver fibrosis and cirrhosis using T1 relaxation times. The study population is based on a radiology-information-system database search for abdominal MRI performed from July 2018 to April 2019 at our institution. After applying exclusion criteria 200 (59 ± 16 yrs) remaining patients were retrospectively included. 93 patients were defined as liver-healthy, 40 patients without known fibrosis or cirrhosis, and 67 subjects had a clinically or biopsy-proven liver fibrosis or cirrhosis. T1 mapping was performed using a slice based look-locker approach. A ROI based analysis of the left and the right liver was performed. Fat fraction, R2*, liver volume, laboratory parameters, sex, and age were evaluated as potential confounding factors. T1 values were significantly lower in healthy subjects without known fibrotic changes (1.5 T MRI: 575 ± 56 ms; 3 T MRI: 857 ± 128 ms) compared to patients with acute liver disease (1.5 T MRI: 657 ± 73 ms, p < 0.0001; 3 T MRI: 952 ± 37 ms, p = 0.028) or known fibrosis or cirrhosis (1.5 T MRI: 644 ± 83 ms, p < 0.0001; 3 T MRI: 995 ± 150 ms, p = 0.018). T1 values correlated moderately with the Child-Pugh stage at 1.5 T (p = 0.01, ρ = 0.35). T1 mapping is a capable predictor for detection of liver fibrosis and cirrhosis. Especially age is not a confounding factor and, hence, age-independent thresholds can be defined. Acute liver diseases are confounding factors and should be ruled out before employing T1-relaxometry based thresholds to screen for patients with liver fibrosis or cirrhosis.

1 December 2020 in Radiology: Cardiothoracic Imaging
Verified
Journal Article
Closed access
MHMaurice Henkel
Maurice Henkel
TWThomas Weikert
Thomas Weikert
KMKatharina Marston
Katharina Marston
NSNathalie Schwab
Nathalie Schwab
GSGregor Sommer
Gregor Sommer
ASAlexander Sauter
Alexander Sauter
Background CT has emerged as an important diagnostic tool in COVID-19, but the underlying pathological changes behind CT findings are not yet fully elucidated. Purpose The purpose of this retrospec...