Veronica Regazzoni

Veronica Regazzoni

Auto-generated profile, based on publicly available information

Veronica Regazzoni

Fondazione Bruno Kessler (FBK), Via Sommarive, 18, 38123, Trento, Italy

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 January 2019 in Sensors
Verified
Journal Article
Open access
PDF file
AGAlberto Gola
Alberto Gola
Fabio AcerbiFabio Acerbi
Fabio Acerbi
MCMassimo Capasso
Massimo Capasso
MMMarco Marcante
Marco Marcante
AMAlberto Mazzi
Alberto Mazzi
NZNicola Zorzi
Nicola Zorzi
Different applications require different customizations of silicon photomultiplier (SiPM) technology. We present a review on the latest SiPM technologies developed at Fondazione Bruno Kessler (FBK, Trento), characterized by a peak detection efficiency in the near-UV and customized according to the needs of different applications. Original near-UV sensitive, high-density SiPMs (NUV-HD), optimized for Positron Emission Tomography (PET) application, feature peak photon detection efficiency (PDE) of 63% at 420 nm with a 35 um cell size and a dark count rate (DCR) of 100 kHz/mm2. Correlated noise probability is around 25% at a PDE of 50% at 420 nm. It provides a coincidence resolving time (CRT) of 100 ps FWHM (full width at half maximum) in the detection of 511 keV photons, when used for the readout of LYSO(Ce) scintillator (Cerium-doped lutetium-yttrium oxyorthosilicate) and down to 75 ps FWHM with LSO(Ce:Ca) scintillator (Cerium and Calcium-doped lutetium oxyorthosilicate). Starting from this technology, we developed three variants, optimized according to different sets of specifications. NUV-HD–LowCT features a 60% reduction of direct crosstalk probability, for applications such as Cherenkov telescope array (CTA). NUV-HD–Cryo was optimized for cryogenic operation and for large photosensitive areas. The reference application, in this case, is the readout of liquid, noble-gases scintillators, such as liquid Argon. Measurements at 77 K showed a remarkably low value of the DCR of a few mHz/mm2. Finally, vacuum-UV (VUV)-HD features an increased sensitivity to VUV light, aiming at direct detection of photons below 200 nm. PDE in excess of 20% at 175 nm was measured in liquid Xenon. In the paper, we discuss the specifications on the SiPM related to different types of applications, the SiPM design challenges and process optimizations, and the results from the experimental characterization of the different, NUV-sensitive technologies developed at FBK.

3 February 2016 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
CPClaudio Piemonte
Claudio Piemonte
Fabio AcerbiFabio Acerbi
Fabio Acerbi
AFAlessandro Ferri
Alessandro Ferri
AGAlberto Gola
Alberto Gola
GPGiovanni Paternoster
Giovanni Paternoster
NZNicola Zorzi
Nicola Zorzi
In this paper, we present the full characterization of a new high-density (HD) cell silicon photomultiplier (SiPM) technology for ultraviolet (UV) and blue light detection, named near UV HD SiPM. Thanks to an optimized border region around each cell, we were able to develop devices having a very high detection efficiency and, at the same time, a high dynamic range. We produced SiPMs with a square cell pitch of 15, 20, 25, and 30 μm featuring a peak efficiency in the violet region ranging from 40% to 55%, according to the cell size. We tested this technology for time-of-flight positron emission tomography. Using two 4 × 4 mm 2 SiPMs with a 25 × 25 μm 2 cell pitch coupled to 3 × 3 × 5 mm 3 LYSO scintillators, we reached for the first time 100-ps full-width at half-maximum coincidence time resolution. This result was independent of the temperature in a range from 20 °C to -20 °C. At the same time, thanks to the high dynamic range and low correlated noise, we obtained an energy resolution lower than 9% for 511-keV γ-rays.

5 January 2017 in IEEE Transactions on Electron Devices
Verified
Journal Article
Open access
Fabio AcerbiFabio Acerbi
Fabio Acerbi
SDStefano Davini
Stefano Davini
AFAlessandro Ferri
Alessandro Ferri
CGCristiano Galbiati
Cristiano Galbiati
GGGraham Giovanetti
Graham Giovanetti
NZNicola Zorzi
Nicola Zorzi
We report on the characterization of near-ultraviolet high-density silicon photomultiplier (SiPM) developed at Fondazione Bruno Kessler (FBK) at cryogenic temperature. A dedicated setup was built to measure the primary dark noise and correlated noise of the SiPMs between 40 and 300 K. Moreover, an analysis program and data acquisition system were developed to allow the precise characterization of these parameters, some of which can vary up to seven orders of magnitude between room temperature and 40 K. We demonstrate that it is possible to operate the FBK near-ultraviolet high density SiPMs at temperatures lower than 100 K with a dark rate below 0.01 cps/mm 2 and total correlated noise probability below 35% at an overvoltage of 6 V. These results are relevant for the development of future cryogenic particle detectors using SiPMs as photosensors.

12 February 2019 in Instruments
Verified
Journal Article
Open access
PDF file
Fabio AcerbiFabio Acerbi
Fabio Acerbi
GPGiovanni Paternoster
Giovanni Paternoster
MCMassimo Capasso
Massimo Capasso
MMMarco Marcante
Marco Marcante
AMAlberto Mazzi
Alberto Mazzi
AGAlberto Gola
Alberto Gola
Silicon photomultipliers (SiPMs) are single-photon sensitive solid-state detectors that are becoming popular for several applications, thanks to massive performance improvements over the last years. Starting as a replacement for the photomultiplier tube (PMT), they are now used in medical applications, big high-energy physics experiments, nuclear physics experiments, spectroscopy, biology and light detection and ranging (LIDAR) applications. Due to different requirements in terms of detection efficiency, noise, etc., several optimizations have been introduced by the manufacturers; for example, spectral sensitivity has been optimized for visible light, near ultraviolet, vacuum ultraviolet, and near infrared light. Each one of them require specific processes and structural optimization. We present in this paper recent improvements in SiPM performance, owing to a higher cell fill-factor, lower noise, improved silicon materials, and deep trench isolation. We describe issues related to the characterization of analog SiPM, particularly due to the different sources of correlated noise, which have to be distinguished from each other and from the primary pulses. We also describe particular analyses and optimizations conducted for specific applications like the readout of liquid noble gas scintillators, requiring these detectors to operate at cryogenic temperatures.

5 February 2018 in IEEE Journal of Quantum Electronics
Verified
Journal Article
Closed access
Fabio AcerbiFabio Acerbi
Fabio Acerbi
GPGiovanni Paternoster
Giovanni Paternoster
AGAlberto Gola
Alberto Gola
VRVeronica Regazzoni
Veronica Regazzoni
NZNicola Zorzi
Nicola Zorzi
CPClaudio Piemonte
Claudio Piemonte
Silicon photomultipliers (SiPM) are photodetectors that have obtained a growing attention in the last years. They have single photon sensitivity, but also a high dynamic range: the output current signal is proportional to the number of detected photons and it is possible to distinguish up to tens of photon per each light pulse. In Fondazione Bruno Kessler (Trento, Italy) we developed the so called high-density SiPMs, with narrow trenches to isolate the cells (i.e. single-photon avalanche diodes) and with high fill factor. These detectors feature high photon detection efficiency and high dynamic range. Moreover, the reduction of the cell size reduces the correlated noise (i.e. lower crosstalk between cells and lower afterpulsing probability) and it makes the single-cell response faster, increasing the maximum counting rate. These characteristics can be very important in applications like light detection and ranging, spectroscopy, and physics experiments. In this paper, we present the structure of high-density SiPMs and their performance. In particular, the photon detection efficiency, the photon number resolving capabilities, the linearity versus photon flux, and the single-photon time resolution, investigating how these parameters change with the cell pitch.

1 November 2016 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
GZG. Zappalà
G. Zappalà
Fabio AcerbiFabio Acerbi
Fabio Acerbi
AFA. Ferri
A. Ferri
AGA. Gola
A. Gola
GPGiovanni Paternoster
Giovanni Paternoster
CPC. Piemonte
C. Piemonte