1 January 2020 in IEEE Access
Local muscle fatigue (LMF) is a common physiological phenomenon that occurs in daily exercise training and medical rehabilitation. Without timely treatment it can easily lead to muscle spasm, ligament rupture, and even stress fractures. Electrical impedance myography (EIM) is a noninvasive bioelectrical impedance technique suitable for the wearable LMF monitoring anytime and anywhere. In this paper, a novel EIM electrode configuration was proposed by establishing a four-layer simulation model of the human upper arm in FEM software. Sensitivity parameters were introduced to optimize muscle selectivity. The effect of fat thickness on impedance change rate was explored to reduce the influence of individual fat differences on EIM results. Dynamic and static contraction experiments of muscle fatigue were performed on the biceps brachii muscles of 10 volunteers to verify the effectiveness and feasibility of the proposed electrode configuration. The proposed electrode configuration reduced the measurement area by 25%, whereas the impedance amplitude and sensitivity remained the same. The influence of individual fat differences on EIM results was significantly reduced. When the fat thickness increased from 6 mm to 18 mm, the impedance change decreased by 31.78% compared with the traditional electrode configuration. When the muscles were extremely exhausted, the decrease in resistance varied around 10 Ω and within 10-1 order of magnitude in different volunteers. In a word, the proposed electrode configuration effectively evaluated the degree of LMF, providing more feasibility for the design of wearable devices.
10 December 2020 in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
Intra-body communication (IBC) is an alternative method for communication of devices in body area networks. The existing research is mainly focused on on-body (OB) channel modeling, transceiver design, and in vivo experiments. However, the difficulty arises in carrying out long-term in vivo experiments for investigating the human channel characteristics in OB or in-body (IB) IBC channels, since the repeatability of in vivo experiments shows inconsistency. In this paper, a multi-layer leg model with realistic shape was designed based on visible human data (VHD) images. Then, novel mixtures with the approximate conductivities of leg tissues were designed and used to fabricate leg phantoms, via several pairs of 3D-printed molds. Finally, the efficiency of the leg phantoms was validated by in vivo experiments through the high similarity of voltage gain versus distance characteristic of the OB channel. Both conditions featured the same trend, that is, they decreased first and then stabilized. The leg phantom was adopted to explore the channel characteristics of the IB channel. The results indicate that the voltage gain versus distance curve of the OB to IB channel was nearly reciprocal. In summary, the VHD-based leg phantom provides a reusable experiment platform for the IBC research, especially for the case of implantable channels.