Li Dongming

Mr. Li Dongming


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in IEEE Access
Verified
Journal Article
Open access
LDLi Dongming
Li Dongming
LHLinnan Huang
Linnan Huang
YWYangrong Wen
Yangrong Wen
YueMing GaoYueMing Gao
YueMing Gao
Zeljka Lucev VasicZeljka Lucev Vasic
Zeljka Lucev Vasic
MDMin Du
Min Du
Local muscle fatigue (LMF) is a common physiological phenomenon that occurs in daily exercise training and medical rehabilitation. Without timely treatment it can easily lead to muscle spasm, ligament rupture, and even stress fractures. Electrical impedance myography (EIM) is a noninvasive bioelectrical impedance technique suitable for the wearable LMF monitoring anytime and anywhere. In this paper, a novel EIM electrode configuration was proposed by establishing a four-layer simulation model of the human upper arm in FEM software. Sensitivity parameters were introduced to optimize muscle selectivity. The effect of fat thickness on impedance change rate was explored to reduce the influence of individual fat differences on EIM results. Dynamic and static contraction experiments of muscle fatigue were performed on the biceps brachii muscles of 10 volunteers to verify the effectiveness and feasibility of the proposed electrode configuration. The proposed electrode configuration reduced the measurement area by 25%, whereas the impedance amplitude and sensitivity remained the same. The influence of individual fat differences on EIM results was significantly reduced. When the fat thickness increased from 6 mm to 18 mm, the impedance change decreased by 31.78% compared with the traditional electrode configuration. When the muscles were extremely exhausted, the decrease in resistance varied around 10 Ω and within 10-1 order of magnitude in different volunteers. In a word, the proposed electrode configuration effectively evaluated the degree of LMF, providing more feasibility for the design of wearable devices.

1 June 2008 in Electrochimica Acta
Verified
Journal Article
Closed access
GZGuohua Zhao
Guohua Zhao
YTYiting Tang
Yiting Tang
Rui ChenRui Chen
Rui Chen
RGRong Geng
Rong Geng
LDLi Dongming
Li Dongming

10 December 2020 in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
Verified
Journal Article
Closed access
LHLinnan Huang
Linnan Huang
YueMing GaoYueMing Gao
YueMing Gao
LDLi Dongming
Li Dongming
Zeljka Lucev VasicZeljka Lucev Vasic
Zeljka Lucev Vasic
MCMario Cifrek
Mario Cifrek
SPSio Hang Pun
Sio Hang Pun
Intra-body communication (IBC) is an alternative method for communication of devices in body area networks. The existing research is mainly focused on on-body (OB) channel modeling, transceiver design, and in vivo experiments. However, the difficulty arises in carrying out long-term in vivo experiments for investigating the human channel characteristics in OB or in-body (IB) IBC channels, since the repeatability of in vivo experiments shows inconsistency. In this paper, a multi-layer leg model with realistic shape was designed based on visible human data (VHD) images. Then, novel mixtures with the approximate conductivities of leg tissues were designed and used to fabricate leg phantoms, via several pairs of 3D-printed molds. Finally, the efficiency of the leg phantoms was validated by in vivo experiments through the high similarity of voltage gain versus distance characteristic of the OB channel. Both conditions featured the same trend, that is, they decreased first and then stabilized. The leg phantom was adopted to explore the channel characteristics of the IB channel. The results indicate that the voltage gain versus distance curve of the OB to IB channel was nearly reciprocal. In summary, the VHD-based leg phantom provides a reusable experiment platform for the IBC research, especially for the case of implantable channels.

22 April 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LDLi Dongming
Li Dongming
JWJiamei Wang
Jiamei Wang
HWHan Wang
Han Wang
XHXiaojiang Huang
Xiaojiang Huang
JYJiejie Yang
Jiejie Yang
Sio Hang PunSio Hang Pun
Sio Hang Pun
Conductive intracardiac communication (CIC) is an essential approach for achieving multichamber pacing in leadless pacemakers (LCPs), significantly enhancing the therapeutic outcomes for conditions, such as bradycardia. However, the characteristics of the intracardiac channel are profoundly affected by the heart’s rhythmic contractions. Accurately understanding the dynamic transmission mechanisms and channel parameters under various cardiac pathological states is crucial for enhancing the multichamber pacing functionality of LCPs. In this article, the relationship between cardiac chamber volume and channel impedance is mapped based on the electrocardiogram (ECG) data. This mapping enables precise, real-time adjustments to variable impedance, simulating the impedance changes occurring with each heartbeat. Through this approach, a time-frequency equivalent circuit phantom is proposed to accurately simulate channel characteristics for various pacemaker indications (PIs). Utilizing a quasi-dual-pump structural analogy to the heart, we designed a dynamic experimental measurement platform capable of simulating the cardiac beating process under various PIs, which is employed to validate the accuracy of the circuit phantom. The results demonstrate that the correlation coefficients in the frequency and time domains are greater than 0.9432 and 0.9150, respectively, with a time-domain consistency coefficient of less than 3.25. Through cross validation in both frequency and time domains, the circuit effectively simulates the channel characteristics of normal and PI hearts. The empirical formula established based on the time-domain measurement results can be utilized for the rapid estimation of the right atrium (RA)–right ventricle (RV) channel characteristics. The proposed phantom offers a highly accurate and reproducible experimental method for the design of intracardiac communication transceivers, advancing the development and validation of leadless multichamber pacemaker systems.

10 November 2023
Verified
Conference Paper
Closed access
Wenxiang ZhaoWenxiang Zhao
Wenxiang Zhao
LDLi Dongming
Li Dongming
JWJiamei Wang
Jiamei Wang
Sio Hang PunSio Hang Pun
Sio Hang Pun
MVMang.I Vai
Mang.I Vai
YueMing GaoYueMing Gao
YueMing Gao
The channel loss of galvanic-coupled human body communication (GC-HBC) is greatly affected by human body activities or individual differences, which will cause large changes in the amplitude of the input signal received by the receiver. This requires the analog front-end to have the ability to adaptively adjust the circuit gain to ensure stable output of the amplified signal. In this regard, this paper proposes an analog front-end with automatic gain control for GC-HBC. This circuit uses a differential preamplifier circuit with high input impedance and a rear-stage automatic gain control circuit that uses voltage feedback to control gain. While achieving amplification of weak signals, it also meets the requirements for stable signal output. The measurement results show that it has an input impedance of $> \mathbf{100}\mathbf{M}\mathbf{\Omega}$ , a maximum gain of 74dB, and a sensitivity of - 76dBm, effectively meeting the needs for capturing and amplifying weak signals. The loop stabilization time is $156\mu\mathrm{s}$ , and the input dynamic range is 34dB, which can ensure stable output of the amplified signal amplitude when the input signal amplitude changes.