Davide Alghisi

Davide Alghisi

Auto-generated profile, based on publicly available information

Davide Alghisi

University of Brescia

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2015 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
DAD. Alghisi
D. Alghisi
SDSimone DALOLA
Simone DALOLA
Marco FerrariMarco Ferrari
Marco Ferrari
Vittorio FerrariVittorio Ferrari
Vittorio Ferrari

1 September 2017 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
DAD. Alghisi
D. Alghisi
Vittorio FerrariVittorio Ferrari
Vittorio Ferrari
Marco FerrariMarco Ferrari
Marco Ferrari
MFM. Ferrari
M. Ferrari
DCD. Crescini
D. Crescini
AMAdel Ben Mnaouer
Adel Ben Mnaouer

1 August 2017 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
DAD. Alghisi
D. Alghisi
Vittorio FerrariVittorio Ferrari
Vittorio Ferrari
Marco FerrariMarco Ferrari
Marco Ferrari
FTF. Touati
F. Touati
DCD. Crescini
D. Crescini
AMAdel Ben Mnaouer
Adel Ben Mnaouer

17 July 2020 in Smart Materials and Structures
Verified
Journal Article
Closed access
Marco BauMarco Bau
Marco Bau
DADavide Alghisi
Davide Alghisi
SDSimone DALOLA
Simone DALOLA
Marco FerrariMarco Ferrari
Marco Ferrari
Vittorio FerrariVittorio Ferrari
Vittorio Ferrari
Energy harvesting from wideband and random vibrations demands for techniques and solutions to overcome limitations of linear converters, which best operate when the frequency of vibrations matches the resonant frequency of the converter. Viable approaches comprise, among others, the use of array of linear harvesters with different resonant frequencies, the adoption of nonlinear techniques or the exploitation of mechanically coupled converters. This work proposes a piezoelectric energy harvester where the combination of such techniques is explored in a unique device. The harvester is composed of an array of four piezoelectric cantilevers fabricated by screen printing lead zirconate titanate (PZT) films on a stainless steel substrate. Nonlinear behavior of the cantilevers is achieved by exploiting the interaction between a magnet and their ferromagnetic steel substrate. Two configurations have been analyzed where the magnet is either fixed on the harvester base, or it is elastically suspended through a spring on the harvester base. The latter configuration introduces a mechanical coupling among the cantilevers. For the experimental characterization, the prototype has been excited by band-pass filtered white-noise mechanical vibrations in the range 10–100 Hz with amplitude in the range 0.1–2.2 g . The obtained experimental results show that the rms values of the open-circuit output voltage for each cantilever increase in the nonlinear configuration and it can be up to 215% higher for the case with the elastically suspended magnet compared to the case of the same array operated in linear regime.

1 January 2012 in Procedia Engineering
Verified
Journal Article
Open access
Marco FerrariMarco Ferrari
Marco Ferrari
DAD. Alghisi
D. Alghisi
Marco BauMarco Bau
Marco Bau
Vittorio FerrariVittorio Ferrari
Vittorio Ferrari
This work proposes and experimentally validates a vibration energy harvester which combines the multi-frequency and nonlinear approaches into a converter array. The converter array consists of four piezoelectric cantilevers composed of ferromagnetic substrates with screen-printed lead zirconate titanate (PZT) layers coupled with a single permanent magnet elastically suspended on the array base in order to create a nonlinear behaviour. The presence of a moving magnet and the possibility to realize cantilevers with different potential curves can be useful to obtain a collective nonlinear behaviour due to strong coupling irrespective of the amplitude of the mechanical excitation, therefore increasing the overall effectiveness of the converter array. The experimental results confirm that combining cantilevers with different potential curves can be useful to obtain a collective bistable behaviour, therefore increasing the overall effectiveness of the converter array

1 March 2015 in IET Circuits, Devices & Systems
Verified
Journal Article
Open access
PDF file
DADavide Alghisi
Davide Alghisi
Marco FerrariMarco Ferrari
Marco Ferrari
Vittorio FerrariVittorio Ferrari
Vittorio Ferrari
This paper presents a battery‐less non‐contact temperature measurement system powered by energy harvesting from intentional human action. The conversion between the human action and electrical energy is provided by a hand‐crank electromagnetic (EM) converter. The AC voltage generated by the EM converter has time‐varying amplitude and frequency and is rectified by a metal–oxide‐semiconductor field‐effect transistor‐based voltage doubler active rectifier circuit. The harvested energy is efficiently stored into multiple capacitors by the innovative sequential charging of storage capacitors technique, and used to power a micro electro mechanical system thermopile sensor with related signal conditioning electronics plus a liquid‐crystal display to visualise the temperature readings. With a force of about 29.4 N over 2 cm applied to the EM converter, the power management circuit is able to extract an energy of 27.5 mJ and power the non‐contact temperature measurement system for about 33 s.