Prakash Kumar

Prakash Kumar

Auto-generated profile, based on publicly available information

Prakash Kumar

Ming Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering University of Southern California Los Angeles CA USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 March 2023 in Pediatric Radiology
Verified
Journal Article
Open access
PDF file
SPSkorn Ponrartana
Skorn Ponrartana
HNHaiThuy N. Nguyen
HaiThuy N. Nguyen
SCSophia X. Cui
Sophia X. Cui
YTYe Tian
Ye Tian
PKPrakash Kumar
Prakash Kumar
Krishna NayakKrishna Nayak
Krishna Nayak
Fetal magnetic resonance imaging (MRI) is an important adjunct modality for the evaluation of fetal abnormalities. Recently, low-field MRI systems at 0.55 Tesla have become available which can produce images on par with 1.5 Tesla systems but with lower power deposition, acoustic noise, and artifact. In this article, we describe a technical innovation using low-field MRI to perform diagnostic quality fetal MRI.

5 October 2023 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
YLYongwan Lim
Yongwan Lim
PKPrakash Kumar
Prakash Kumar
Krishna NayakKrishna Nayak
Krishna Nayak
Purpose: To demonstrate speech‐production real‐time MRI (RT‐MRI) using a contemporary 0.55T system, and to identify opportunities for improved performance compared with conventional field strengths.Methods: Experiments were performed on healthy adult volunteers using a 0.55T MRI system with high‐performance gradients and a custom 8‐channel upper airway coil. Imaging was performed using spiral‐based balanced SSFP and gradient‐recalled echo (GRE) pulse sequences using a temporal finite‐difference constrained reconstruction. Speech‐production RT‐MRI was performed with three spiral readout durations (8.90, 5.58, and 3.48 ms) to determine trade‐offs with respect to articulator contrast, blurring, banding artifacts, and overall image quality.Results: Both spiral GRE and bSSFP captured tongue boundary dynamics during rapid consonant‐vowel syllables. Although bSSFP provided substantially higher SNR in all vocal tract articulators than GRE, it suffered from banding artifacts at TR > 10.9 ms. Spiral bSSFP with the shortest readout duration (3.48 ms, TR = 5.30 ms) had the best image quality, with a 1.54‐times boost in SNR compared with an equivalent GRE sequence. Longer readout durations led to increased SNR efficiency and blurring in both bSSFP and GRE.Conclusion: High‐performance 0.55T MRI systems can be used for speech‐production RT‐MRI. Spiral bSSFP can be used without suffering from banding artifacts in vocal tract articulators, provide better SNR efficiency, and have better image quality than what is typically achieved at 1.5 T or 3 T.

18 October 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
DLDuc H. Le
Duc H. Le
PKPrakash Kumar
Prakash Kumar
EYEcrin Yagiz
Ecrin Yagiz
YTYe Tian
Ye Tian
Krishna NayakKrishna Nayak
Krishna Nayak
Purpose: To develop a low‐latency dynamic MRI reconstruction that provides better spatial and temporal fidelity than contemporary online reconstruction, for localization. Methods: We utilize online spatiotemporally constrained reconstruction (STCR) using a computationally efficient augmented Lagrangian solution and a limited number of iterations that terminate before the acquisition of the next frame. Online STCR is evaluated in the setting of fetal cardiac localization at 0.55 T, and is compared with online view‐sharing and offline compressed sensing, using edge sharpness metrics. Results: Online STCR has the highest structural similarity index measure (SSIM) to offline STCR among the compared online reconstruction methods. Spatial edge sharpness improved by 13% 2% and temporal edge sharpness improved by 34% 4% compared to view‐sharing. Conclusion: We demonstrate low‐latency reconstruction for 2D real‐time MRI at 1.5 1.5 mm spatial resolution, 31.8 ms temporal resolution, and 240 240 mm FOV. We demonstrate that online STCR improves the depiction of rapidly moving boundaries, compared to standard view‐sharing.

16 October 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
SMShaihan Malik
Shaihan Malik
ESEfrat Shimron
Efrat Shimron
SSSophie Schauman
Sophie Schauman
Krishna NayakKrishna Nayak
Krishna Nayak
PKPrakash Kumar
Prakash Kumar
PJPeter Jezzard
Peter Jezzard

2 September 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PKPrakash Kumar
Prakash Kumar
Krishna NayakKrishna Nayak
Krishna Nayak
Purpose: To determine the feasibility of tagged MRI at 0.55 T and tag persistence for cardiac and speech production applications. This is particularly challenging due to the short muscle T 1 at 0.55 T (701 ms) and requires advanced techniques for maximizing initial tag contrast and signal‐to‐noise ratio (SNR)–efficient imaging. Methods: Tagged MRI was performed using phase‐sensitive tagging (REALTAG) two‐dimensional grid‐based preparation and spiral balanced steady‐state free precession (bSSFP) imaging. Experiments were performed in healthy adult volunteers using a 0.55 T MRI system with high‐performance gradients on two functional anatomies. Cardiac scans had 7.5‐mm tag spacing, 1.3‐mm 2 in‐plane resolution, and were acquired during about 18s breath‐holds. Speech scans had 10‐mm tag spacing, 2‐mm 2 spatial resolution, and were acquired in real time. Resulting tagged images were compared with conventional gradient‐recalled echo (GRE). Tag persistence and tag contrast‐to‐noise ratio were measured and compared. Results: REALTAG preparation and phase‐sensitive reconstruction resulted in taglines that recover quickly when compared to 1.5 T, for both bSSFP and GRE imaging approaches. The bSSFP approach, at optimal flip angles, provided a 1.35‐fold improved SNR and 1.6‐fold improved tag persistence. For a tag contrast‐to‐noise ratio threshold of 6, the tag persistence was about 506 ms for GRE and about 851 ms for bSSFP. Conclusion: Tagged MRI is feasible at 0.55 T and can be used for functional analysis of muscle motion such as cardiac and speech applications, despite the short T 1 . Spiral bSSFP along with REALTAG preparation pulses provide adequate SNR and contrast to visualize cardiac systolic mechanics and to visualize tongue deformation during short speech utterances.

24 August 2026 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PKPrakash Kumar
Prakash Kumar
RRRajiv Ramasawmy
Rajiv Ramasawmy
AJAhsan Javed
Ahsan Javed
DLDuc Le
Duc Le
PDPierre Daudé
Pierre Daudé
ACAdrienne E. Campbell-Washburn
Adrienne E. Campbell-Washburn