Marcel P. Bruijn

Marcel P. Bruijn

Auto-generated profile, based on publicly available information

Marcel P. Bruijn

NWO-I/SRON Space Research Organisation Netherlands, Leiden, The Netherlands

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2021 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
HAH. Akamatsu
H. Akamatsu
DVD. Vaccaro
D. Vaccaro
LGLuciano Gottardi
Luciano Gottardi
JKJ. van der Kuur
J. van der Kuur
CVC. P. de Vries
C. P. de Vries
JHJ.-W. A. Den Herder
J.-W. A. Den Herder
We report on the development and demonstration of MHz frequency domain multiplexing (FDM) technology to readout arrays of cryogenic transition edge sensor (TES) x-ray microcalorimeters. In our FDM scheme, TESs are AC biased at different resonant frequencies in the low MHz range through an array of high-Q LC resonators. The current signals of all TESs are summed at superconducting quantum interference devices (SQUIDs). We have demonstrated multiplexing for a readout of 31 pixels using room temperature electronics, high-Q LC filters, and TES arrays developed at SRON, and SQUID arrays from VTT. We repeated this on a second setup with 37 pixels. The summed x-ray spectral resolutions @ 5.9 keV are ΔE31pix MUX=2.14 ± 0.03 eV and ΔE37pix MUX=2.23 ± 0.03 eV. The demonstrated results are comparable with other multiplexing approaches. There is potential to further improve the spectral resolution, to increase the number of multiplexed TESs, and to open up applications for TES x-ray microcalorimeters.

8 December 2020 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
MWMartin de Wit
Martin de Wit
LGL. Gottardi
L. Gottardi
Emanuele TaralliEmanuele Taralli
Emanuele Taralli
KNKenichiro Nagayashi
Kenichiro Nagayashi
MRM. L. Ridder
M. L. Ridder
JHJ.-W. A. Den Herder
J.-W. A. Den Herder
We are developing large Transition Edge Sensor (TES) arrays in combination with a frequency domain multiplexing readout for the next generation of X-ray space observatories. For operation under an AC-bias, the TESs have to be carefully designed and optimized. In particular, the use of high aspect ratio devices will help us to mitigate non-ideal behavior due to the weak-link effect. In this paper, we present a full characterization of a TES array containing five different device geometries, with aspect ratios (width:length) ranging from 1:2 up to 1:6. The complex impedance of all geometries is measured in different bias configurations to study the evolution of the small-signal limit superconducting transition parameters α and β , as well as the excess noise. We show that high aspect ratio devices with properly tuned critical temperatures (around 90 mK) can achieve excellent energy resolution, with an array average of 2.03 ± 0.17 eV at 5.9 keV and a best achieved resolution of 1.63 ± 0.17 eV. This demonstrates that AC-biased TESs can achieve a very competitive performance compared to DC-biased TESs. The results have motivated a push to even more extreme device geometries currently in development.

21 September 2020 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
YNY. Nakashima
Y. Nakashima
FHF. Hirayama
F. Hirayama
SKS. Kohjiro
S. Kohjiro
HYH. Yamamori
H. Yamamori
SNS. Nagasawa
S. Nagasawa
JHJ. W. A. Den Herder
J. W. A. Den Herder
We report very-low-noise, fast-response, middle-scale multiplexing in a microwave superconducting quantum interference device multiplexer (MW-Mux) as a transition-edge sensor (TES) readout. Our MW-Mux is able to read 40 channels with 500 kHz sampling and has a low readout noise of 0.9   μ Φ 0 / Hz (where Φ 0 is the magnetic flux quantum), equivalent to 9   pA / Hz . By contrast, a multiplexer of less than 10 pixels with 500 kHz sampling and ∼ 2   μ Φ 0 / Hz readout noise has so far been reported in the literature. Owing to the 500 kHz sampling, our MW-Mux exhibits a fast response to detect a TES pulse with a rise time around 12   μ s . We demonstrated simultaneous readout of 38 pixels from an array of x-ray TES microcalorimeters. The measured full-width values at half-maximum spectral resolution ranged from 2.79 to 4.56 eV, with a median value of 3.30 eV at 5.9 keV, including a ∼ 10 % contribution of readout noise, i.e., 0.9–1.7 eV.

1 April 2019 in AIP Advances
Verified
Journal Article
Open access
PDF file
ETE. Taralli
E. Taralli
PKP. Khosropanah
P. Khosropanah
LGL. Gottardi
L. Gottardi
KNK. Nagayoshi
K. Nagayoshi
MRM. L. Ridder
M. L. Ridder
JGJ. R. Gao
J. R. Gao
The next generation of Far-infrared and X-ray space observatories will require detector arrays with thousands of transition edge sensor (TES) pixel. It is extremely important to have a tool that is able to characterize all the pixels and that can give a clear picture of the performance of the devices. In particular, we refer to those aspects that can affect the global energy resolution of the array: logarithmic resistance sensitivity with respect to temperature and current (α and β parameters, respectively), uniformity of the TESs and the correct understanding of the detector thermal model. Complex impedance measurement of a TES is the only technique that can give all this information at once, but it has been established only for a single pixel under DC bias. We have developed a complex impedance measurement method for TESs that are AC biased since we are using a MHz frequency domain multiplexing (FDM) system to readout an array. The FDM readout demands for some modifications to the complex-impedance technique and extra considerations, e.g. how to modulate a small fraction of the bias carrier frequencies in order to get a proper excitation current through the TESs and how to perform an accurate demodulation and recombination of the output signals. Also, it requires careful calibration to remove the presence of parasitic impedances in the entire readout system. We perform a complete set of AC impedance measurements for different X-ray TES microcalorimeters based on superconducting TiAu bilayers with or without normal metal Au bar structures. We discuss the statistical analysis of the residual between impedance data and fitting model to determine the proper calorimeter thermal model for our detectors. Extracted parameters are used to improve our understanding of the differences and capabilities among the detectors and additionally the quality of the array. Moreover, we use the results to compare the calculated noise spectra with the measured data.

30 November 2011 in Journal of Low Temperature Physics
Verified
Journal Article
Closed access
PDF file
MBM. P. Bruijn
M. P. Bruijn
LGL. Gottardi
L. Gottardi
RHR. H. Den Hartog
R. H. Den Hartog
HHH. F. C. Hoevers
H. F. C. Hoevers
MKM. Kiviranta
M. Kiviranta
JKJ. van der Kuur
J. van der Kuur

1 May 2019 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
LGL. Gottardi
L. Gottardi
HWH. van Weers
H. van Weers
JDJ. Dercksen
J. Dercksen
HAH. Akamatsu
H. Akamatsu
MBM. P. Bruijn
M. P. Bruijn
MRM. L. Ridder
M. L. Ridder
Dilution and adiabatic demagnetization refrigerators based on pulse tube cryocoolers are nowadays used in many low temperature physics experiments, such as atomic force and scanning tunneling microscopy, quantum computing, radiation detectors, and many others. A pulse tube refrigerator greatly simplifies the laboratory activities being a cryogen-free system. The major disadvantage of a pulse tube cooler is the high level of mechanical vibrations at the warm and cold interfaces that could substantially affect the performance of very sensitive cryogenic instruments. In this paper, we describe the performance of a very simple mechanical attenuation system used to eliminate the pulse-tube-induced low frequency noise of the superconducting transition-edge sensors under development for the instruments of the next generation of infra-red and X-ray space observatories.