U. O'Connor

U. O'Connor

Auto-generated profile, based on publicly available information

U. O'Connor

Department of Medical Physics and Bioengineering, St James's Hospital, Dublin, Ireland

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2013 in British Journal of Radiology
Verified
Journal Article
Open access
UOU O’cOnnor
U O’cOnnor
AGA Gallagher
A Gallagher
LML Malone
L Malone
GOG O’rEilly
G O’rEilly
Objective:Endoscopic retrograde cholangiopancreatography (ERCP) is a common procedure that combines the use of X-ray fluoroscopy and endoscopy for examination of the bile duct. Published data on ERCP doses are limited, including staff eye dose from ERCP. Occupational eye doses are of particular interest now as the International Commission on Radiological Protection (ICRP) has recommended a reduction in the dose limit to the lens of the eye. The aim of this study was to measure occupational eye doses obtained from ERCP procedures.Methods:A new eye lens dosemeter (EYE-D™, Radcard, Krakow, Poland) was used to measure the ERCP eye dose, Hp(3), at two endoscopy departments in Ireland. A review of radiation protection practice at the two facilities was also carried out.Results:The mean equivalent dose to the lens of the eye of a gastroenterologist is 0.01 mSv per ERCP procedure with an undercouch X-ray tube and 0.09 mSv per ERCP procedure with an overcouch X-ray tube. Staff eye dose normalised to patient kerma ...

1 May 2015 in British Journal of Radiology
Verified
Journal Article
Closed access
UOU O'Connor
U O'Connor
CWC Walsh
C Walsh
AGA Gallagher
A Gallagher
ADA Dowling
A Dowling
MGM Guiney
M Guiney
GOG O'Reilly
G O'Reilly
In 2011, the International Commission on Radiological Protection (ICRP) recommended a substantial reduction in the equivalent dose limit for the lens of the eye, in line with a reduced threshold of absorbed dose for radiation-induced cataracts. This is of particular relevance in interventional radiology (IR) where it is well established that staff doses can be significant, however, there is a lack of data on IR eye doses in terms of Hp(3). Hp(3) is the personal dose equivalent at a depth of 3 mm in soft tissue and is used for measuring lens dose. We aimed to obtain a reliable estimate of eye dose to IR operators. Lens doses were measured for four interventional radiologists over a 3-month period using dosemeters specifically designed to measure Hp(3). Based on their typical workloads, two of the four interventional radiologists would exceed the new ICRP dose limit with annual estimated doses of 31 and 45 mSv to their left eye. These results are for an "unprotected" eye, and for IR staff who routinely wear lead glasses, the dose beneath the glasses is likely to be significantly lower. Staff eye dose normalized to patient kerma-area product and eye dose per procedure have been included in the analysis. Eye doses to IR operators have been established using a dedicated Hp(3) dosemeter. Estimated annual doses have the potential to exceed the new ICRP limit. We have estimated lens dose to interventional radiologists in terms of Hp(3) for the first time in an Irish hospital setting.

5 October 2022 in Journal of Radiological Protection
Verified
Journal Article
Open access
UOU O’cOnnor
U O’cOnnor
CWC Walsh
C Walsh
DGD Gorman
D Gorman
GOG O’rEilly
G O’rEilly
ZMZ Martin
Z Martin
FVF Vanhavere
F Vanhavere
Individual monitoring of radiation workers is essential to ensure compliance with legal dose limits and to ensure that doses are As Low As Reasonably Achievable. However, large uncertainties still exist in personal dosimetry and there are issues with compliance and incorrect wearing of dosimeters. The objective of the PODIUM (Personal Online Dosimetry Using Computational Methods) project was to improve personal dosimetry by an innovative approach: the development of an online dosimetry application based on computer simulations without the use of physical dosimeters. Occupational doses were calculated based on the use of camera tracking devices, flexible individualised phantoms and data from the radiation source. When combined with fast Monte Carlo simulation codes, the aim was to perform personal dosimetry in real-time. A key component of the PODIUM project was to assess and validate the methodology in interventional radiology workplaces where improvements in dosimetry are needed. This paper describes the feasibility of implementing the PODIUM approach in a clinical setting. Validation was carried out using dosimeters worn by Vascular Surgeons and Interventional Cardiologists during patient procedures at a hospital in Ireland. Our preliminary results from this feasibility study show acceptable differences of the order of 40% between calculated and measured staff doses, in terms of the personal dose equivalent quantity Hp(10), however there is a greater deviation for more complex cases and improvements are needed. The challenges of using the system in busy interventional rooms have informed the future needs and applicability of PODIUM. The availability of an online personal dosimetry application has the potential to overcome problems that arise from the use of current dosimeters. In addition, it should increase awareness of radiation protection among staff. Some limitations remain and a second phase of development would be required to bring the PODIUM method into operation in a hospital setting. However, an early prototype system has been tested in a clinical setting and the results from this two-year proof-of-concept PODIUM project are very promising for future development.

1 July 2021 in Physica Medica
Verified
Journal Article
Open access
UOU. O'COnnor
U. O'COnnor
ECE. Carinou
E. Carinou
ICI. Clairand
I. Clairand
OBOlivera Ciraj Bjelac
Olivera Ciraj Bjelac
FMF. De Monte
F. De Monte
FVF. Vanhavere
F. Vanhavere
Occupational radiation doses from interventional procedures have the potential to be relatively high. The requirement to optimise these doses encourages the use of electronic or active personal dosimeters (APDs) which are now increasingly used in hospitals. They are typically used in tandem with a routine passive dosimetry monitoring programme, with APDs used for real-time readings, for training purposes and when new imaging technology is introduced. However, there are limitations when using APDs. A survey in hospitals to identify issues related to the use of APDs was recently completed, along with an extensive series of APD tests by the EURADOS Working Group 12 on Dosimetry for Medical Imaging. The aim of this review paper is to summarise the state of the art regarding the use of APDs. We also used the results of our survey and our tests to develop a set of recommendations for the use of APDs in the clinical interventional radiology/cardiology settings, and draw attention to some of the current challenges.

18 February 2008 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
JZJ. Zoetelief
J. Zoetelief
FSFrank Schultz
Frank Schultz
SKSofia Kottou
Sofia Kottou
LGL. Gray
L. Gray
UOU. O'Connor
U. O'Connor
JVJ. Vassileva
J. Vassileva
Quality control (QC) is becoming increasingly important in relation to the introduction of digital medical imaging systems using X rays. It was, therefore, decided to organise and perform a trial on image quality and physical measurements. The SENTINEL toolkit for QC measurements of fluoroscopy systems containing equipment and instructions for their use in the assessment of dose and image quality circulated among participants in the trial. The participants reported on their results. In the present contribution, the impact of the trial on the selected protocols is presented. The Medical Physics and Bioengineering protocol appeared to be useful for QC, and also for digital systems. The protocol needs an additional section, or an addition to each section, to state compliance with the requirements. The circular cross-sections of the Leeds test objects need adaptation for rectangular flat panel detector (FPD) systems. Only one participant was able to perform the monitor test using MoniQA. This is due to the fact that assistance is required from the suppliers of the X-ray systems. This problem needs to be solved to apply MoniQA in practice.

18 April 2022 in Environments
Verified
Journal Article
Open access
PDF file
PFPaolo Ferrari
Paolo Ferrari
MGMercè Ginjaume
Mercè Ginjaume
OHOliver Hupe
Oliver Hupe
UOUna O’connor
Una O’connor
FVFilip Vanhavere
Filip Vanhavere
MŽMilena Živković
Milena Živković
EURADOS (European Radiation Dosimetry Group) Working Group 12 (WG12) SG1 activities are aimed at occupational radiation protection and individual monitoring in X-ray and nuclear medicine practices. In recent years, many studies have been carried out in these fields, especially for interventional radiology and cardiology workplaces (IC/IR). The complexity of the exposure conditions of the medical staff during interventional practices makes the radiation protection and monitoring of the exposed workers a challenging task. The scope of the present work is to review some of the main results obtained within WG12 activities about scattered field characterization and personal dosimetry that could be very useful in increasing the quality of radiation protection of the personnel, safety, and awareness of radiation risk. Two papers on Monte Carlo modelling of interventional theater and three papers on active personal dosimeters (APDs) for personnel monitoring were considered in the review. More specifically, Monte Carlo simulation was used as the main tool to characterize the levels of exposure of the medical staff, allowing to determine how beam energy and direction can have an impact on the doses received by the operators. Indeed, the simulations provided information about the exposure of the operator’s head, and the study concluded with the determination of an eye-lens protection factor when protection goggles and a ceiling shielding are used. Moreover, the review included the results of studies on active personal dosimeters, their use in IC/IR workplaces, and how they respond to calibration fields, with X-ray standard and pulsed beams. It was shown that APDs are insensitive to backscatter radiation, but some of them could not respond correctly to the very intense pulsed fields (as those next to the patient in interventional practices). The measurements during interventional procedures showed the potential capability of the employment of APDs in hospitals.