Yixiang Wang

Yixiang Wang

Auto-generated profile, based on publicly available information

Yixiang Wang

College of Mechanical and Electrical Engineering, Wenzhou University, Wenzhou 325035, China

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 August 2021 in ACS Omega
Verified
Journal Article
Open access
YWYixiang Wang
Yixiang Wang
LWLei Wang
Lei Wang
XJXianhang Ji
Xianhang Ji
YZYulu Zhou
Yulu Zhou
WMWu Mingge
Wu Mingge
Excess water seriously affects the performance and lifetime of proton exchange membrane fuel cells (PEMFCs). This study proposes a novel compound flow field, which is named the active drainage flow field (ADFF). The new design enhances the drainage performance by under-ribs flow, while the output performance is very close to that of the conventional serpentine flow field (CSFF). Additionally, the ADFF bipolar plate has been taken as a cathode while retaining CSFF as an anode; the combination shows a good output performance under high relative humidity. The peak power density has reached to 0.59 W/cm2, which is 13% higher than that of the CSFF.

8 April 2024 in Langmuir
Verified
Journal Article
Closed access
YLYong Ju Lee
Yong Ju Lee
YWYi Xiang Wang
Yi Xiang Wang
YJYoon Chang Jeong
Yoon Chang Jeong
MAMichael D. Atkins
Michael D. Atkins
KKKiju Kang
Kiju Kang
TKTongbeum Kim
Tongbeum Kim

1 April 2016
Verified
Conference Paper
Closed access
YWYixiang Wang
Yixiang Wang
HDHong Ding
Hong Ding
XLXianhao Le
Xianhao Le
Jin XieJin Xie
Jin Xie
In this paper, we firstly present a MEMS (microelectromechanical systems) piezoelectric in-plane resonant accelerometer with two-stage micro-leverage mechanism. Double ended tuning fork (DETF) resonators are actuated and sensed by piezoelectric transduction with aluminum nitride (AlN). Optimized configuration of DETF resonators and two-stage micro-leverage mechanism are proposed to enhance sensitivity of the resonant accelerometer. The preliminary characterization of the device was tested in a vacuum chamber at the pressure of 4 mTorr. The sensitivity of the device is 28.4Hz/g at the base frequency around 141 kHz (201 ppm/g), which is higher than the previously reported data.

1 December 2020
Verified
Conference Paper
Closed access
SHShanguo Huang
Shanguo Huang
BGBingli Guo
Bingli Guo
YYYabo Yuan
Yabo Yuan
BWBo Wang
Bo Wang
YZYu Zhang
Yu Zhang
YLYiting Liu
Yiting Liu
A network control architecture and Advanced Orbiting Systems (AOS) frame switching scheme suitable for inter-satellite optical network are proposed and demonstrated. The proposed scheme will facilitate on-board data forwarding of resource and energy hungry satellite by avoiding unnecessary data packing and unpacking for bypass traffic.

17 November 2021 in ACS Omega
Verified
Journal Article
Open access
WMWu Mingge
Wu Mingge
XJXianhang Ji
Xianhang Ji
YWYixiang Wang
Yixiang Wang
YZYulu Zhou
Yulu Zhou
RJRui Jiang
Rui Jiang
In developing a proton exchange membrane fuel cell, a high current density is encountered, thus requiring a novel flow field with great drainage performance. Our previous study proposed a novel compound flow field called an active drainage flow field with three inlets, which has an excellent output and drainage performance. Furthermore, the influence of muti-inlet reactant gas allocation on the three inlets is discussed in this study. The results showed that the small mass flow in the active drainage (AD) channel causes a waste of active area, while the large mass flow in the AD channel causes under-ribs convection. Considering the output and drainage performance, the 15% AD mass flow case shows the best performance under the high relative humidity investigation.