1 December 2015 in Meteorological Applications
The study describes significant outcomes of the ‘Metrology for Meteorology’ project, MeteoMet, which is an attempt to bridge the meteorological and metrological communities. The concept of traceability, an idea used in both fields but with a subtle difference in meaning, is at the heart of the project. For meteorology, a traceable measurement is the one that can be traced back to a particular instrument, time and location. From a metrological perspective, traceability further implies that the measurement can be traced back to a primary realization of the quantity being measured in terms of the base units of the International System of Units, the SI. These two perspectives reflect long‐standing differences in culture and practice and this project – and this study – represents only the first step towards better communication between the two communities.The 3 year MeteoMet project was funded by the European Metrology Research Program (EMRP) and involved 18 European National Metrological Institutes, 3 universities and 35 collaborating stakeholders including national meteorology organizations, research institutes, universities, associations and instrument companies.The project brought a metrological perspective to several long‐standing measurement problems in meteorology and climatology, varying from conventional ground‐based measurements to those made in the upper atmosphere. It included development and testing of novel instrumentation as well as improved calibration procedures and facilities, instrument intercomparison under realistic conditions and best practice dissemination. Additionally, the validation of historical temperature data series with respect to measurement uncertainties and a methodology for recalculation of the values were included.
13 March 2020 in Science Advances
Space cooling in buildings is anticipated to rise because of an increasing thermal comfort demand worldwide, and this calls for cost-effective and sustainable cooling technologies. We present a proof-of-concept multistage device, where a net cooling capacity and a temperature difference are demonstrated as long as two water solutions at disparate salinity are maintained. Each stage is made of two hydrophilic layers separated by a hydrophobic membrane. An imbalance in water activity in the two layers naturally causes a non-isothermal vapor flux across the membrane without requiring any mechanical ancillaries. One prototype of the device developed a specific cooling capacity of up to 170 W m−2 at a vanishing temperature difference, considering a 3.1 mol/kg calcium chloride solution. To provide perspective, if successfully up-scaled, this concept may help satisfy at least partially the cooling needs in hot, humid regions with naturally available salinity gradients.
26 June 2013 in International Journal of Climatology
Solar radiation screens play a key role in automatic weather stations (AWS) performances. In this work, screen ageing effects on temperature measurements are examined. Paired temperature observations, traceable to national standards and with a well‐defined uncertainty budget, were performed employing two naturally ventilated weather stations equipped with identical sensors and different only for their working time. Three different tests were carried out employing different aged AWSs: a 5‐year‐old AWS (AWS5) was compared with a new device (AWS0), a 1 year old (AWS1) was compared with both a 3 years old (AWS3) and a new one devices (AWS00). Due to solar and weather conditions exposure a degradation of the screen reflective coating is evident for the older AWSs (5 and 3 years old) and so a qualitative estimation of how different conditions of ageing affect the temperature drift was done. During the comparison 0 to 5 and 1 to 3‐year‐old screens, significant temperature differences were recorded at different times of the day. The differences, wider than the uncertainty amplitude, demonstrate a systematic effect. The temperature measured with the older screen is larger, and the maximum instantaneous difference was 1.63 °C (for 0–5 years comparison) in daytime hours. During night‐time the two AWS's measure the same temperature (within the uncertainty amplitude). This behaviour, increasing with increasing solar radiation intensity and decreasing with increasing wind speed, is attributed to a radiative heating effect. The screen ageing has compromised the shield effectiveness introducing a significant change in the temperature evaluation. The experimental results of a further comparison, between 0‐ and 1‐year‐old screens, confirm the same conclusion showing a negligible ageing effect, within the uncertainty amplitude.
26 February 2024 in Physical Review A
Doppler-broadening gas thermometry is extended to the deep-ultraviolet domain using a comb-locked laser frequency chain, expressly developed for precision spectroscopy of mercury vapors at the wavelength of 253.7 nm, in coincidence with the intercombination line. The system is based on a double-stage second-harmonic generation process of an external-cavity diode laser at 1014.8 nm, which is frequency locked to a self-referenced optical-frequency-comb synthesizer by means of an efficient nonlinear frequency-mixing scheme. An absolute frequency axis in the UV region is produced by scanning the comb repetition rate, with the entire frequency chain following the reference comb tooth. The complete characterization of the phase noise of the comb-locked near-infrared laser demonstrates line-emission narrowing down to the limit imposed by the coherence of the comb teeth. After a proper processing of the phase noise, the Gaussian and Lorentzian components of the width of the UV radiation are determined. This is useful to estimate the instrumental perturbation to the probed mercury line for the aims of thermodynamic temperature metrology. In this regard, the preliminary spectroscopic results are quite promising, despite the difficulties arising from the short wavelength of operation.
28 April 2016 in Physical Review A
Spectroscopic parameters (line intensity factor, pressure self-broadening, and shifting coefficients) of at were accurately measured using a dual-laser approach, based upon the technique of optical phase locking. This generated an absolute frequency scale underneath the absorption spectra. A pair of extended-cavity diode lasers was used. One of them, the probe laser, is forced to maintain a precise frequency offset from a reference laser, which is an optical frequency standard based on noise-immune cavity-enhanced optical heterodyne molecular spectroscopy. Laser-gas interaction takes place inside an isothermal multipass cell that is stabilized at the temperature of the triple point of water. The fidelity in the observation of the shape associated to the (14) line of the band allowed us to measure the spectroscopic parameters, with a global uncertainty for the line strength of 0.22%.
16 November 2015 in Meteorological Applications
Environmental monitoring by automatic weather stations (AWSs) is growing as a result of the increasing number and reliability of surface observations. In order to ensure data traceability and obtain more comprehensive data on the performance of AWSs, a new transportable calibration facility was manufactured at the Italian Institute of Metrology (INRiM) in the framework of the project MeteoMet. The facility is equipped with temperature and pressure reference sensors directly traceable to the International System of Units (SI) to obtain meteorological data with well‐documented calibration uncertainty.In this calibration system, temperature and pressure can be controlled simultaneously and independently so that all combinations over the ranges are possible. The nominal ranges are: absolute pressure 50 to 110 kPa and temperature −25 to 50 °C. The availability of a large range of atmospheric variability and the possibility of studying the mutual influence effects on sensors response are important characteristics of the facility.This apparatus is also designed to permit a control in humidity, in order to complete the characterization of the whole AWS pressure–temperature–humidity modulus. As a matter of fact, the final version of the facility will be equipped with a humidity generator for hygrometer calibrations.Finally, the calibration system is designed to be transportable, therefore allowing the calibration of AWSs located at sites that are difficult to access such as Ny‐Ålesund (Svalbard) stations, where the facility was employed.The design and the technical characteristics are reported in this paper.